文献速递生殖医学

氧化还原电位测定用于氧化应激检测的诊断应用:在男性因素不育中的临床价值

Diagnostic application of oxidation-reduction potential assay for measurement of oxidative stress: clinical utility in male factor infertility.
PubMed 文献 · Reprod Biomed Online · 2016-10-20

本研究描述了用MiOXSYS系统测定精液氧化还原电位(ORP)的方案,建立静态ORP(sORP)参考值以区分对照组与男性因素不育患者,评估观察者内与观察者间可靠性,并检验sORP与预测男性因素不育的精子参数的关联。不育患者sORP升高(6.22 ± 1.10 mV/10^6精子/ml)vs 对照组(1.59 ± 0.29 mV/10^6精子/ml)(P = 0.004)。sORP截断值1.36 mV/10^6精子/ml区分正常与异常精液质量的敏感性69.6%、特异性83.1%、阳性预测值85.3%、阴性预测值65.9%。

要点

  • 不育患者sORP为6.22 ± 1.10 mV/10^6精子/ml,高于对照组的1.59 ± 0.29 mV/10^6精子/ml(P = 0.004)。
  • sORP截断值1.36 mV/10^6精子/ml区分正常与异常精液质量:敏感性69.6%、特异性83.1%、阳性预测值85.3%、阴性预测值65.9%。
  • sORP与精子浓度、总精子数、活力和形态呈负相关,提示这些男性不育参数与氧化应激相关。

核心结论

  • 引入ORP作为评估氧化应激的新型临床检测将帮助临床医生更好地诊断和管理男性因素不育患者。

研究设计与样本

  • 研究描述了用MiOXSYS系统测定ORP作为精液氧化应激检测替代方法的方案,并建立sORP参考值以区分对照组与男性因素不育患者。
  • 研究评估了观察者内与观察者间可靠性,并检验sORP与预测男性因素不育的精子参数的关联。

主要发现

  • 不育患者sORP为6.22 ± 1.10 mV/10^6精子/ml,高于对照组的1.59 ± 0.29 mV/10^6精子/ml(P = 0.004)。
  • sORP截断值1.36 mV/10^6精子/ml区分正常与异常精液质量,敏感性69.6%、特异性83.1%、阳性预测值85.3%、阴性预测值65.9%。
  • 该检测显示较强的观察者内可靠性(CV 8.39%)和观察者间可靠性(相关性>0.97)。
  • 较高的sORP水平与受试者生育状态下的不良精子参数相关。
  • sORP与精子参数(浓度、总精子数、活力和形态)呈负相关,表明这些男性不育参数与氧化应激相关。

关键数值与推荐

  • sORP截断值1.36 mV/10^6精子/ml用于区分正常与异常精液质量:敏感性69.6%、特异性83.1%、阳性预测值85.3%、阴性预测值65.9%。
  • 观察者内可靠性CV 8.39%,观察者间相关性>0.97。

临床怎么用

  • 原文未据此给出推荐。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

The objectives of this study were to: (i) describe a protocol measuring the oxidation-reduction potential (ORP) by MiOXSYS System as an alternative method of seminal oxidative stress (OS) testing; (ii) establish a reference value for static ORP (sORP) to distinguish between controls and male factor infertility patients; (iii) evaluate intra-observer and inter-observer reliability; and (iv) examine association of sORP with sperm parameters predictive of male factor infertility. Elevated levels of sORP were seen in infertile patients (6.22 ± 1.10 mV/106 sperm/ml) compared with controls (1.59 ± 0.29 mV/106 sperm/ml) (P = 0.004). A sORP cut-off value 1.36 mV/106 sperm/ml identified normal semen and abnormal semen quality with a sensitivity 69.6%, specificity 83.1%, positive predictive value 85.3% and negative predictive value 65.9%. The test demonstrated strong intra-observer (CV 8.39%) and inter-observer reliability (correlations >0.97). Higher sORP levels were associated with poor sperm parameters across the fertility status of subjects. Negative correlations were noted with sperm parameters (concentration, total sperm count, motility and morphology) indicating these male infertility parameters are related to OS. In conclusion, the introduction of ORP as a novel clinical test for assessment of OS will help clinicians to better diagnose and manage male factor infertility patients.

来源:Reprod Biomed Online,查看原文。版权归原作者所有。

引用

  1. Agarwal A, Roychoudhury S, Sharma R, et al. Diagnostic application of oxidation-reduction potential assay for measurement of oxidative stress: clinical utility in male factor infertility. Reprod Biomed Online. 2016. PMID: 27839743. doi:10.1016/j.rbmo.2016.10.008

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。