基于宫缩的子宫动脉多普勒测速:预测先兆早产孕妇早产的新方法
这项前瞻性队列研究纳入172例孕24–35周因宫缩入院患者,在宫缩峰值时行子宫动脉多普勒测速并测量宫颈长度。宫缩峰值子宫动脉搏动指数(UtA-PI)预测7天内分娩的曲线下面积为0.88,≥1.32时7天内分娩的校正OR为16.5(95%CI 5.7–47.2)。作者认为该指标可能有助于识别有早产风险的孕妇。
要点
- 宫缩峰值UtA-PI预测48小时、7天、14天、≤35周、≤37周分娩的AUC分别为0.92、0.88、0.81、0.83、0.74。
- 7天内分娩的校正OR:宫缩峰值UtA-PI≥1.32为16.5(95%CI 5.7–47.2),宫颈长度≤28 mm为14.7(95%CI 5.2–41.8)。
- 作者认为宫缩峰值子宫动脉多普勒测速可能有效识别有早产风险的孕妇。
核心结论
- 对出现早产症状的患者,在宫缩峰值时使用子宫动脉多普勒测速可能有效识别有早产风险的孕妇。
研究设计与样本
- 前瞻性队列研究,纳入172例因孕24–35周宫缩入院的患者,在宫缩峰值时行子宫动脉多普勒测速并测量宫颈长度等常规产科指标。
主要发现
- 7天内分娩者的宫缩峰值UtA-PI显著高于未在7天内分娩者(P < 0.001)。
- 宫缩峰值UtA-PI预测48小时、7天、14天、≤35周和≤37周分娩的AUC分别为0.92、0.88、0.81、0.83和0.74。
- 多因素回归分析显示宫缩峰值UtA-PI(P < 0.001)和宫颈长度(P < 0.001)是入院至分娩间隔的预测因素。
- 7天内分娩的校正OR:宫缩峰值UtA-PI≥1.32为16.5(95% CI,5.7–47.2),宫颈长度≤28 mm为14.7(95% CI,5.2–41.8)。
关键数值与推荐
- 宫缩峰值UtA-PI≥1.32时,7天内分娩的校正OR为16.5(95% CI,5.7–47.2)。
- 宫颈长度≤28 mm时,7天内分娩的校正OR为14.7(95% CI,5.2–41.8)。
临床怎么用
- 作者认为,对出现早产症状的患者,宫缩峰值子宫动脉多普勒测速可能有效识别有早产风险的孕妇。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
OBJECTIVE: To evaluate whether uterine artery (UtA) Doppler velocimetry during peak uterine contraction is a useful marker for the prediction of preterm delivery. METHODS: In this prospective cohort study, 172 patients admitted with preterm (24-35 weeks' gestation) uterine contractions were evaluated by UtA Doppler velocimetry during peak uterine contraction and by common obstetric measurements including cervical length. For UtA Doppler velocimetry, flow-velocity waveforms during peak uterine contraction (determined visually on tocodynamometry) were recorded during three consecutive heart cycles, and the mean UtA pulsatility index (UtA-PI) was calculated. RESULTS: UtA-PI during the peak of contractions was significantly higher in patients who delivered within 7 days than in those who did not (P < 0.001). On receiver-operating characteristics curve analysis of UtA-PI on contraction, the areas under the curve for prediction of delivery within 48 h, 7 days or 14 days, ≤ 35 weeks and ≤ 37 weeks were 0.92, 0.88, 0.81, 0.83 and 0.74, respectively. Multiple regression analysis identified UtA-PI on contraction (P < 0.001) and cervical length (P < 0.001) as predictors of admission-to-delivery interval. The corresponding adjusted odds ratios for delivery within 7 days were 16.5 (95% CI, 5.7-47.2) for UtA-PI on contraction ≥ 1.32, and 14.7 (95% CI, 5.2-41.8) for cervical length ≤ 28 mm. CONCLUSION: Use of UtA Doppler velocimetry during peak uterine contraction for patients exhibiting symptoms of preterm labor might be effective for the identification of pregnant women at risk of preterm delivery. Copyright © 2016 ISUOG. Published by John Wiley & Sons Ltd.
引用
- Olgan S, Celiloglu M. Contraction-based uterine artery Doppler velocimetry: novel approach for prediction of preterm birth in women with threatened preterm labor. Ultrasound Obstet Gynecol. 2016. PMID: 26823022. doi:10.1002/uog.15871
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。