盐水对比超声子宫造影在异常子宫出血育龄女性中检测子宫内膜息肉和黏膜下子宫肌瘤的准确性:系统综述与Meta分析
本系统综述与Meta分析纳入5项诊断研究,比较二维和三维盐水对比超声子宫造影(SCSH)与宫腔镜及解剖病理学诊断子宫内膜息肉和黏膜下子宫肌瘤的准确性。二维SCSH检测子宫内膜息肉的合并敏感度和特异度分别为93%(95%CI,89-96%)和81%(95%CI,76-86%),检测黏膜下子宫肌瘤分别为94%(95%CI,89-97%)和81%(95%CI,76-86%)。三维SCSH研究因异质性高无法比较。
要点
- 二维SCSH检测子宫内膜息肉敏感度93%、特异度81%,LR+为5.41、LR-为0.10。
- 二维SCSH检测黏膜下子宫肌瘤敏感度94%、特异度81%,LR+为4.25、LR-为0.11。
- 三维SCSH研究因异质性高未能进行合并比较,育龄女性中需更多研究。
核心结论
- 二维SCSH被证明是检测子宫内膜息肉和黏膜下子宫肌瘤的高敏感度方法,可能成为异常子宫出血女性检查中的一线诊断方法。
- 育龄女性中关于三维SCSH需要更多研究。
研究设计与样本
- 按PRISMA和SEDATE推荐进行的诊断性研究系统综述,比较二维和/或三维SCSH与宫腔镜及解剖病理学。
- 检索MEDLINE、EMBASE和Cochrane Library,无语言或发表年份限制,使用QUADAS-2工具评估质量,Meta分析采用Meta-DiSk程序。
- 共识别1398条文献,系统综述和Meta分析纳入5项研究。
主要发现
- 二维SCSH检测子宫内膜息肉的合并敏感度为93%(95%CI,89-96%),合并特异度为81%(95%CI,76-86%),合并LR+为5.41(95%CI,2.60-11.28),LR-为0.10(95%CI,0.06-0.17)。
- 二维SCSH检测黏膜下子宫肌瘤的合并敏感度为94%(95%CI,89-97%),合并特异度为81%(95%CI,76-86%),合并LR+为4.25(95%CI,2.20-8.21),LR-为0.11(95%CI,0.05-0.22)。
- 二维SCSH检测子宫内膜息肉和黏膜下子宫肌瘤的SROC曲线下面积分别为0.97±0.02和0.97±0.03。
- 分析三维SCSH诊断准确性的研究因绝经状态、所用技术类型和主要结局为不孕症调查相关的高异质性而无法比较。
关键数值与推荐
- 二维SCSH检测子宫内膜息肉:敏感度93%(95%CI,89-96%),特异度81%(95%CI,76-86%),LR+ 5.41(95%CI,2.60-11.28),LR- 0.10(95%CI,0.06-0.17)。
- 二维SCSH检测黏膜下子宫肌瘤:敏感度94%(95%CI,89-97%),特异度81%(95%CI,76-86%),LR+ 4.25(95%CI,2.20-8.21),LR- 0.11(95%CI,0.05-0.22)。
临床怎么用
- 二维SCSH被证明是检测子宫内膜息肉和黏膜下子宫肌瘤的高敏感度方法,可能成为异常子宫出血女性检查中的一线诊断方法(作者结论)。
- 育龄女性中关于三维SCSH需要更多研究(作者结论)。
局限性
- 分析三维SCSH诊断准确性的研究因绝经状态、所用技术类型和主要结局为不孕症调查相关的高异质性而无法比较。
- 育龄女性中关于三维SCSH需要更多研究。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
OBJECTIVE: To analyze the diagnostic accuracy of two- (2D) and three- (3D) dimensional saline contrast sonohysterography (SCSH) in the detection of endometrial polyps and submucosal uterine leiomyomas in women of reproductive age with abnormal uterine bleeding compared with gold standard hysteroscopy. METHODS: A systematic review of diagnostic studies that compared 2D- and/or 3D-SCSH with hysteroscopy and anatomopathology was conducted according to PRISMA and SEDATE recommendations. The databases MEDLINE, EMBASE and The Cochrane Library were searched electronically using specific terms with no restriction on language or publication year. Quality assessment of included studies was performed using the QUADAS-2 tool. Meta-analysis was performed with the Meta-DiSk program and data presented as forest plots and summary receiver-operating characteristics (SROC) curves. Pooled sensitivity, specificity and positive (LR+) and negative (LR-) likelihood ratios of SCSH in the detection of uterine cavity abnormalities were calculated. RESULTS: A total of 1398 citations were identified and five studies were included in the systematic review and meta-analysis. Pooled sensitivity and specificity of 2D-SCSH in detecting endometrial polyps were 93% (95% CI, 89-96%) and 81% (95% CI, 76-86%), respectively, with pooled LR+ of 5.41 (95% CI, 2.60-11.28) and LR- of 0.10 (95% CI, 0.06-0.17). In the detection of submucosal uterine leiomyomas, pooled sensitivity and specificity were 94% (95% CI, 89-97%) and 81% (95% CI, 76-86%), respectively, with pooled LR+ of 4.25 (95% CI, 2.20-8.21) and LR- of 0.11 (95% CI, 0.05-0.22). 2D-SCSH had good accuracy in detecting endometrial polyps and submucosal uterine leiomyomas, with areas under the SROC curves of 0.97 ± 0.02 and 0.97 ± 0.03, respectively. Studies that analyzed the diagnostic accuracy of 3D-SCSH could not be compared due to high heterogeneity related to menopausal status, type of technique used and primary outcome being investigation of infertility. CONCLUSIONS: 2D-SCSH proved to be a highly sensitive method for detection of endometrial polyps and submucosal uterine leiomyomas, making it a potential first-line diagnostic method in the work-up for women with abnormal uterine bleeding. More studies are needed on 3D-SCSH in women of reproductive age. Copyright © 2016 ISUOG. Published by John Wiley & Sons Ltd.
引用
- Bittencourt CA, Dos Santos Simões R, Bernardo WM, et al. Accuracy of saline contrast sonohysterography in detection of endometrial polyps and submucosal leiomyomas in women of reproductive age with abnormal uterine bleeding: systematic review and meta-analysis. Ultrasound Obstet Gynecol. 2017. PMID: 27862503. doi:10.1002/uog.17352
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。