异常子宫出血女性息肉与平滑肌瘤的影像学检查:一项系统综述
该系统综述检索至2015年11月,纳入25项研究,比较宫腔超声造影与经阴道超声诊断异常子宫出血女性息肉和黏膜下平滑肌瘤的准确性,以宫腔镜或子宫切除标本病理为金标准。宫腔超声造影汇总敏感度0.92、特异度0.89,优于经阴道超声的0.64和0.90(P<.001);经阴道超声诊断息肉敏感度尤其低(0.51)。
要点
- 宫腔超声造影汇总敏感度0.92、特异度0.89,优于经阴道超声(0.64、0.90,P<.001)。
- 经阴道超声诊断息肉敏感度尤其低(0.51),单独使用不足以排除息肉和平滑肌瘤。
- 宫腔超声造影与宫腔镜敏感度相似但特异度较低(0.83 vs 0.90,P=.007)。
核心结论
- 经阴道超声缺乏足够敏感度,不能单独用于排除异常子宫出血女性的息肉和平滑肌瘤。
- 宫腔超声造影虽特异度低于宫腔镜,但检测率相似,并可同时观察卵巢和子宫肌层。
- 不同影像技术的费用、便利性和耐受性需进一步评估。
研究设计与样本
- 系统综述,检索MEDLINE、EMBASE、CENTRAL和ClinicalTrials.gov及引文和参考文献列表,截至2015年11月。
- 两位作者筛选5,347条引文,纳入以宫腔镜或子宫切除标本病理为金标准、评估宫腔超声造影和经阴道超声诊断准确性的随机对照试验或前瞻性队列研究。
- 共25项研究符合纳入标准,采用双变量随机效应模型比较不同检查并评估异质性来源。
主要发现
- 宫腔超声造影汇总敏感度和特异度分别为0.92和0.89,经阴道超声分别为0.64和0.90(P<.001)。
- 经阴道超声诊断息肉的敏感度为0.51。
- 7项研究比较宫腔超声造影与宫腔镜,敏感度相似(0.93 vs 0.95),特异度较低(0.83 vs 0.90,P=.007)。
- 三种检查均耐受良好,宫腔超声造影在95%的女性中成功完成。
- 使用球囊导管等技术差异未发现影响诊断准确性。
局限性
- 不同影像技术的费用、便利性和耐受性需进一步评估。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
OBJECTIVE: To evaluate the accuracy of saline infusion sonohysterography in comparison with transvaginal ultrasonography for diagnosing polyps and submucosal leiomyomas in women with abnormal uterine bleeding. DATA SOURCES: We searched the databases MEDLINE, EMBASE, CENTRAL, and ClinicalTrials.gov as well as citations and reference lists to the end of November 2015. METHODS OF STUDY SELECTION: Two authors screened 5,347 citations for eligibility. We included randomized controlled trials or prospective cohort studies published in English, assessing the accuracy of saline infusion sonohysterography and transvaginal ultrasonography for diagnosing polyps and submucosal leiomyomas in women with abnormal uterine bleeding. We considered studies using histopathologic specimens obtained at either hysteroscopy or hysterectomy as criterion standard. TABULATION, INTEGRATION, AND RESULTS: Twenty-five studies were eligible. Two authors extracted data and assessed the quality of included studies. Bivariate random-effects models were used to compare the different tests and evaluate sources of heterogeneity. Saline infusion sonohysterography was superior to transvaginal ultrasonography with pooled sensitivity and specificity of 0.92 and 0.89 compared with 0.64 and 0.90, respectively (P<.001). Transvaginal ultrasound sensitivity for diagnosing polyps was particularly low (0.51). Saline infusion sonohysterography was also compared with hysteroscopy in seven studies and had similar sensitivity but inferior specificity (0.93 and 0.83 compared with 0.95 and 0.90, respectively, P=.007). All three procedures were well-tolerated by women. Saline infusion sonohysterography was successfully completed in 95% of women. Technical variations such as the use of balloon catheters were not found to affect diagnostic accuracy. CONCLUSION: Transvaginal ultrasonography lacks sensitivity to be used alone to exclude the presence of polyps and leiomyomas in women with abnormal uterine bleeding. Although less specific than hysteroscopy, saline infusion sonohysterography offers a similar detection rate and permits concomitant visualization of the ovaries and myometrium. Cost, convenience, and tolerability of different imaging techniques require further evaluation. SYSTEMATIC REVIEW REGISTRATION: PROSPERO International prospective register of systematic reviews, http://www.crd.york.ac.uk/PROSPERO, CRD42016034005.
引用
- Maheux-Lacroix S, Li F, Laberge PY, et al. Imaging for Polyps and Leiomyomas in Women With Abnormal Uterine Bleeding: A Systematic Review. Obstet Gynecol. 2016. PMID: 27824761. doi:10.1097/AOG.0000000000001776
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。