可调节缝线子宫悬吊术用于困难腹腔镜子宫肌瘤剔除术
回顾性队列研究纳入158例后壁深部肌壁间、阔韧带或宫颈肌瘤患者,81例行可调节缝线子宫悬吊术(USAS),77例未行悬吊。悬吊组腹部穿刺孔数、出血量、手术时间及中转开腹率均低于对照组,并发症及3年妇科与生殖结局无显著差异。
要点
- USAS建立平均耗时2.5分钟,采用2-0聚丙烯缝线经腹悬吊子宫。
- 悬吊组平均穿刺孔3个、出血96.3 mL、手术50.8分钟,均低于对照组。
- 悬吊组中转开腹比值比为0.108(95%CI 0.013-0.884),低于对照组。
核心结论
- USAS是困难腹腔镜子宫肌瘤剔除术中替代子宫操纵的简便、安全、可行的选择。
研究设计与样本
- 回顾性队列研究(加拿大任务 force 分类II-2),在大学教学医院进行,共纳入158例后壁深部肌壁间、阔韧带或宫颈肌瘤患者,其中81例行USAS(悬吊组),77例未行USAS(对照组),均同期行腹腔镜子宫肌瘤剔除术。
主要发现
- 悬吊组与对照组平均腹部穿刺孔数分别为3个和4.4个(p < .001),平均出血量分别为96.3 mL和201.5 mL(p < .001),平均手术时间分别为50.8分钟和91.2分钟(p < .001)。
- 悬吊组与对照组并发症发生率分别为4.9%和9.1%(p = .303),无显著差异;中转开腹率分别为1.2%和10.4%(p = .009),有显著差异。
- 悬吊组中转开腹的比值比为0.108(95%CI 0.013-0.884),远低于对照组。
- 3年随访时,两组在肌瘤复发、子宫破裂、妊娠率及活产率等妇科与生殖结局方面无显著差异。
临床怎么用
- 作者认为,对于子宫肌瘤位置不利、无法使用子宫操纵器的患者,在腹腔镜子宫肌瘤剔除术中可考虑行经腹可调节缝线子宫悬吊术。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
STUDY OBJECTIVE: To assess whether transabdominal uterine suspension with adjustable sutures (USAS) is beneficial when performed concomitantly with laparoscopic myomectomy in patients with unfavorably localized leiomyomas in whom uterine manipulators are not an option. DESIGN: A retrospective cohort study (Canadian Task Force classification II-2). SETTING: A university teaching hospital. PATIENTS: Patients (N = 158) with posterior deep intramural, intraligamental, or cervical leiomyomas; 81 patients underwent USAS (suspension group), and 77 patients did not (control group) concomitantly with laparoscopic myomectomy. INTERVENTIONS: Transabdominal USAS was performed for all eligible patients undergoing laparoscopic myomectomy using a 2-0 synthetic, monofilament, nonabsorbable polypropylene suture. One end of the double-headed straight needles of the polypropylene suture was inserted into the pelvic cavity through the abdomen to "lift" or "retract" the uterus to allow for the main tumor to be completely exposed and excised. MEASUREMENTS AND MAIN RESULTS: The average time to create USAS was 2.5 minutes. For the suspension and control groups, the average number of abdominal ports was 3 and 4.4 (p < .001), the average blood loss was 96.3 and 201.5 mL (p < .001), and the average operative time was 50.8 and 91.2 minutes (p < .001), respectively. There was no significant difference in complications (4.9% vs 9.1%, p = .303), but there was a significant difference in conversion to laparotomy (1.2% vs 10.4%, p = .009). At the 3-year follow-up, there were no significant differences in gynecologic and reproductive outcomes, including leiomyoma recurrence, uterine rupture, and pregnancy and live birth rates. The ratio of conversion to laparotomy (odds ratio = 0.108; 95% confidence interval, 0.013-0.884) was much lower in the suspension group. CONCLUSION: USAS is an easy, safe, and feasible alternative to uterine manipulation when performed concomitantly with laparoscopic myomectomy for unfavorably localized uterine leiomyomas.
引用
- Chen KH, Seow KM, Chen LR, et al. Uterine Suspension With Adjustable Sutures for Difficult Laparoscopic Myomectomy. J Minim Invasive Gynecol. 2016. PMID: 27816617. doi:10.1016/j.jmig.2016.10.015
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。