肥胖对机器人辅助骶骨阴道固定术的影响
回顾性队列研究纳入2009至2013年由同一术者连续完成的179例机器人辅助骶骨阴道固定术患者,按体重指数分为正常体重组61例、超重组72例和肥胖组46例。三组中位手术时间分别为202、206和216分钟(p=.53),肥胖患者的手术时间与程序特征与正常体重及超重患者相似。
要点
- 肥胖组与正常体重、超重组机器人辅助骶骨阴道固定术的中位手术时间无显著差异(p=.53)。
- 超重患者较其他组年龄更大、产次更多、绝经后比例更高,且更常同时行输卵管卵巢切除术。
- 肥胖女性行机器人辅助骶骨阴道固定术的手术时间与程序特征与正常体重和超重患者相似。
核心结论
- 肥胖女性行机器人辅助骶骨阴道固定术的手术时间和程序特征与正常体重及超重患者相似。
- 需要更长期结局以确保相当的手术和解剖学成功。
研究设计与样本
- 回顾性队列研究(加拿大任务组分类II-2)。
- 大学附属教学医院,2009年至2013年由同一术者连续完成的179例机器人辅助骶骨阴道固定术患者。
- 按体重指数分组:正常体重(BMI<25 kg/m2)61例(34%),超重(BMI 25-30 kg/m2)72例(40%),肥胖(BMI≥30 kg/m2)46例(26%)。
主要发现
- 正常体重组、超重组和肥胖组的中位手术时间分别为202、206和216分钟(p=.53)。
- 超重患者显著年龄更大、产次更多、更常绝经后,且更常同时行输卵管卵巢切除术。
局限性
- 需要更长期结局以确保相当的手术和解剖学成功。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
STUDY OBJECTIVE: To compare operative time in women stratified by body mass index (BMI) undergoing robotic-assisted sacrocolpopexy (RASC). Secondary objectives included characterizing perioperative characteristics and reoperation rates. DESIGN: Retrospective cohort study (Canadian Task Force classification II-2). SETTING: University-affiliated teaching hospital. PATIENTS: One hundred seventy-nine consecutive patients who underwent RASC by a single surgeon from 2009 through 2013. INTERVENTIONS: RASC. MEASUREMENTS AND MAIN RESULTS: Of 179 patients, 61 (34%) were normal weight (BMI < 25 kg/m2), 72 (40%) were overweight (BMI 25-30 kg/m2), and 46 (26%) were obese (BMI ≥ 30 kg/m2). Overweight patients were significantly older, more parous, more frequently postmenopausal, and more frequently underwent concomitant salpingo-oophorectomy. Median operative times were 202, 206, and 216 minutes in the normal-weight, overweight, and obese groups, respectively (p = .53). CONCLUSION: Obese women undergoing RASC have similar operative time and procedural characteristics as normal-weight and overweight patients. Longer term outcomes are needed to ensure comparable surgical and anatomic success.
引用
- Kissane LM, Calixte R, Grigorescu B, et al. Impact of Obesity on Robotic-Assisted Sacrocolpopexy. J Minim Invasive Gynecol. 2016. PMID: 27810437. doi:10.1016/j.jmig.2016.10.012
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。