胎儿死后显微CT对腹盆腔异常的诊断检出率
本研究回顾性分析2017至2024年间1200例非选择性连续胎儿全身死后显微CT扫描,评估腹盆腔异常的检出情况。结果显示196/1200例(16.3%)胎儿共检出277处腹盆腔异常,最常见为腹盆壁缺损和肾脏异常。即使存在重度浸渍,显微CT在多数病例中仍可诊断,仅17/1200例(1.4%)扫描不可诊断。
要点
- 死后显微CT可检出早期妊娠丢失胎儿的多种腹盆腔异常,重度浸渍下多数仍可诊断。
- 最常见腹盆腔异常为腹盆壁缺损(30.3%)和肾脏异常(27.8%)。
- 不可诊断扫描仅占1.4%,提示该方法在胎儿死后评估中具有较高适用性。
核心结论
- 死后显微CT能够在早期妊娠丢失胎儿中识别多种腹盆腔异常,即使存在重度浸渍,多数仍可诊断。
研究设计与样本
- 回顾性分析2017至2024年间1200例非选择性连续胎儿全身死后显微CT扫描队列。
主要发现
- 196/1200例(16.3%)胎儿共检出277处腹盆腔异常,平均孕周17周(范围10–24;中位17,四分位距4)。
- 平均胎儿体重96.5 g(范围0.25–484.2;中位48.3,四分位距105.6)。
- 277处异常中,100处(36.1%)仅腹部,61处(22.0%)仅盆腔,27处(9.7%)腹盆腔均有,96处(34.7%)为外部异常。
- 最常见异常为腹盆壁缺损84/277(30.3%)和肾脏异常77/277(27.8%)。
- 肾脏异常中马蹄肾16/77(20.8%)和囊性肾13/77(16.9%)最常见。
临床怎么用
- 对早期妊娠丢失胎儿进行死后评估时,可考虑使用显微CT识别腹盆腔结构异常。
- 重度浸渍不应作为放弃显微CT评估的绝对排除条件。
局限性
- 本研究为回顾性分析,未与常规尸检进行系统性对照。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
ABSTRACT Objective(s) This study aims to document the abdominal and pelvic anomalies that can be demonstrated using post mortem Micro-CT, independent of whether the anomaly contributed to the main diagnosis or cause of death. Methods We retrospectively analyzed 1200 whole body post-mortem fetal Micro-CT scans in an unselected, consecutive cohort between 2017 and 2024. Abdominal or pelvic anomalies were categorized into internal or external anomalies. Results Overall, 277 individual abdominal/pelvic anomalies were identified in 196/1200 (16.3%) fetuses with a mean gestational age of 17 weeks (range 10–24; median 17, interquartile range 4), and a mean fetal body weight 96.5 g (range 0.25–484.2; median 48.3, interquartile range 105.6). Of these, 100/277 (36.1%) were abdominal only, 61/277 (22.0%) pelvic only, 27/277 (9.7%) were both, and 96/277 (34.7%) were external anomalies. The most common anomalies were abdominal-pelvic wall defects 84/277 (30.3%), and renal anomalies 77/277 (27.8%), with horseshoe kidneys 16/77 (20.8%) and cystic kidneys 13/77 (16.9%) being the most common renal anomalies. Severe maceration was identified in 80 fetuses (grade 5 or 6), although imaging was still diagnostic in most cases, with only 17/1200 (1.4%) non-diagnostic scans. Conclusion(s) Post-mortem Micro-CT imaging can identify a wide range of abdominal/pelvic anomalies following pregnancy loss in early gestation fetuses, even in the presence of severe maceration.
引用
- Prenatal Diagnosis:Diagnostic Yield of Post‐Mortem Fetal Micro‐CT for Abdominal and Pelvic Anomalies
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。