这项前瞻性多中心随机对照优效性试验纳入119例18-45岁拟行腹腔镜单侧卵巢肿物(3-10cm)囊肿剥除的绝经前女性,最终分析105例(干预组53例、对照组52例)。干预组术中肉眼泄漏为0.0%(0/53),显著低于对照组的25.0%(13/52)(RD -25.0%,95%CI -36.8%至-13.2%,P<0.001),术中破裂率与手术时间两组相近。中位随访34.5个月,对照组5例(9.6%)出现新发慢性盆腔痛,干预组0例。

要点

  • 全封闭保护装置可显著降低腹腔镜卵巢畸胎瘤剥除术中肉眼泄漏(0.0% vs 25.0%)。
  • 两组术中破裂率(32.1% vs 25.0%)与手术时间无显著差异。
  • 中位随访34.5个月,干预组无新发慢性盆腔痛,对照组5例(9.6%)。

核心结论

  • 在该研究队列中,全封闭保护装置提供了有效的物理屏障,术中未观察到肉眼泄漏。
  • 初步结果显示,标准化这种封闭取出策略与本样本中无长期并发症(特别是慢性盆腔痛)相关。

研究设计与样本

  • 前瞻性、多中心、随机对照优效性试验(1:1),在中国北京四家学术医疗中心开展。
  • 纳入119例18-45岁拟行腹腔镜单侧卵巢肿物(3-10cm)囊肿剥除的绝经前女性,排除后分析105例(干预组53例、对照组52例)。
  • 干预组使用全封闭保护装置进行封闭式剥除/取出,对照组采用常规剥除后标准取物袋取出。

主要发现

  • 装置部署成功率为100%。
  • 主要结局肉眼泄漏:干预组0.0%(0/53)显著低于对照组25.0%(13/52)(RD -25.0%,95%CI -36.8%至-13.2%,P<0.001)。
  • 术中破裂率两组相近:32.1% vs 25.0%(RD 7.1%,95%CI -10.3%至24.5%,P=0.422)。
  • 手术时间两组相似。
  • 中位随访34.5个月,对照组5例(9.6%)出现新发慢性盆腔痛,干预组0例。

临床怎么用

  • 在腹腔镜卵巢畸胎瘤囊肿剥除术中,可考虑采用全封闭保护装置进行封闭式剥除与取出,以减少术中肉眼泄漏。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

OBJECTIVE: To evaluate a "Totally Enclosed Protective Device" in preventing macroscopic intraoperative leakage during laparoscopic ovarian cystectomy compared to conventional methods. DESIGN: Prospective, multicenter, randomized controlled superiority trial (1:1). SETTING: Four academic medical centers in Beijing, China. PARTICIPANTS: 119 premenopausal women (18-45 years) scheduled for laparoscopic cystectomy for unilateral ovarian masses (3-10 cm) were randomized. After exclusions, 105 participants (intervention: 53; control: 52) were analyzed. INTERVENTIONS: Laparoscopic cystectomy using the device for contained decortication/extraction, versus conventional decortication followed by standard retrieval bag extraction. MEASUREMENTS AND MAIN RESULTS: Device deployment success was 100%. Macroscopic leakage (primary outcome) was significantly lower in the intervention group (0.0%, 0/53) than controls (25.0%, 13/52) (risk difference [RD], -25.0%; 95% CI, -36.8% to -13.2%; P<0.001). Intraoperative rupture rates were comparable (32.1% vs. 25.0%; RD, 7.1%; 95% CI, -10.3% to 24.5%; P=0.422). Operative times were similar. Over a 34.5-month median follow-up, 5 control patients (9.6%) developed new-onset chronic pelvic pain, versus 0 in the intervention group. CONCLUSION: Within this study cohort, the device provided an effective physical barrier, and no macroscopic intraoperative spillage was observed. Preliminary findings suggest that standardizing this contained extraction strategy is associated with the absence of long-term complications, specifically chronic pelvic pain, in this sample. FUNDING: This study was supported by Capital's Funds for Health Improvement and Research (No. 2022-2-406). CLINICAL TRIAL REGISTRATION: Registration Number: NCT04406597; Date of Registration: May 20, 2022.