文献速递母胎医学产科

双胎间体重不一致预测激光术后供血儿存活的最佳切点

Identifying an optimal inter-twin weight discordance cutoff for predicting donor survival after fetoscopic laser surgery for twin-twin transfusion syndrome.
PubMed 文献 · Am J Obstet Gynecol MFM · 2026-08-10

本研究回顾性分析2009至2022年单中心169例接受胎儿镜激光手术(FLS)的TTTS单绒毛膜双羊膜囊双胎,评估双胎间体重不一致对供血儿存活的预测价值。结果显示不一致≥25%与供血儿存活率较低相关,但单独预测能力较差,最优切点为29%。

要点

  • 不一致≥25%与FLS后供血儿存活率降低相关。
  • 不一致≥25%和≥30%均与供血儿存活率下降显著相关。
  • 不一致单独预测供血儿存活的AUC为0.63,最优切点29%。

核心结论

  • 双胎间体重不一致≥25%与TTTS行FLS后供血儿存活率较低相关。
  • 但单独使用不一致预测供血儿存活能力较差,若用于临床,29%切点在本队列中预测价值最高。

研究设计与样本

  • 回顾性研究,纳入2009至2022年单中心169例接受FLS的MCDA双胎TTTS妊娠。
  • 主要结局为FLS后首次超声检查时供血儿存活。

主要发现

  • 62例(37%)术前不一致≥25%。
  • 不一致≥25%组供血儿选择性胎儿生长受限更常见(74.2% vs 23.4%,p<.01)。
  • 不一致≥25%组FLS后首次超声供血儿存活率较低(75.8% vs 89.7%,p=.02),新生儿出院时存活率也较低(52.8% vs 73.6%,p=.04)。
  • 调整年龄、Quintero分期和供血儿FGR后,不一致≥25%组首次超声供血儿存活率仍较低(p=.01)。
  • 不一致作为连续变量预测供血儿存活的AUC为0.63(95% CI: 0.49, 0.74,p=.06)。

关键数值与推荐

  • 不一致≥25%和≥30%均与FLS后首次超声供血儿存活率降低显著相关(p=.03和p<.001),调整供血儿FGR和术前Quintero分期后仍显著。
  • 基于Youden指数,最优切点为29%,预测供血儿存活的敏感性0.75、特异性0.58、阳性预测值0.91、阴性预测值0.29。

临床怎么用

  • 术前可考虑使用29%的不一致切点进行供血儿预期存活的咨询。
  • 不应单独依赖双胎间体重不一致预测供血儿存活。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

BACKGROUND: Increased inter-twin growth discordance has been associated with adverse pregnancy outcomes. An inter-twin growth discordance of at least 25% is often considered as a clinical threshold for pathological discordance in unselected monochorionic-diamniotic (MCDA) twins, but an optimal cutoff for predicting survival outcomes following fetoscopic laser surgery (FLS) for twin-twin transfusion syndrome (TTTS) is unclear. OBJECTIVES: This study aimed to (1) compare outcomes of FLS for TTTS based upon on the presence or absence of discordance ≥25%, (2) evaluate the association of different inter-twin discordance thresholds on donor twin survival after FLS, and (3) identify an optimal discordance cutoff for the prediction of donor twin survival. STUDY DESIGN: Retrospective review of MCDA twins with TTTS that underwent FLS at a single center from 2009 to 2022. The primary outcome was donor twin survival at first sonogram after FLS. Pregnancies with preoperative inter-twin discordance ≥25% were compared to those <25%. Differing thresholds of inter-twin discordance were compared to determine predictive accuracy for donor twin survival, and discordance was examined as a continuous variable to determine an optimal cutoff for donor twin survival prediction. RESULTS: A total of 169 MCDA pregnancies underwent FLS and met inclusion criteria and 62 (37%) had inter-twin discordance ≥25%. Patients with inter-twin discordance ≥25% were younger (32±5 years vs 30±6 years, p=.03). Gestational age at TTTS diagnosis and at FLS were similar between groups. Donor twin selective fetal growth restriction (sFGR) was more likely with discordance ≥25% (74.2% vs 23.4%, p<.01). Pre-FLS Quintero stage differed between the 2 groups (p=.014), with higher likelihood of stage III and IV disease in the ≥25% group. Discordance ≥25% was associated with lower donor twin survival at first post-FLS sonogram (75.8% vs 89.7%, p=.02) and at newborn hospital discharge (52.8% vs 73.6%, p=.04). After adjusting for age, Quintero stage, and donor FGR, donor twin survival at first sonogram remained lower in patients with discordance ≥25% (p=.01). Discordance cutoffs of ≥25% and ≥30% were significantly associated with decreased donor twin survival at first sonogram post-FLS (p=.03 and p<.001, respectively) and this was true after adjusting for donor fetal growth restriction and pre-FLS Quintero stage. In fitting a logistic regression model, discordance as a continuous variable was significantly associated with predicting donor twin survival (p=.02). The area under the curve (AUC) for predicting donor twin survival was 0.63 (95% CI: 0.49, 0.74, p=.06). Based on the Youden index, the optimum cut point was a discordance of 29%, which had a sensitivity of 0.75, specificity of 0.58, positive predictive value of 0.91, and negative predictive value of 0.29 for predicting donor twin survival. CONCLUSION: Discordance ≥25% was associated with lower donor twin survival after FLS for TTTS; however, inter-twin discordance alone is a poor predictor of donor twin survival after FLS for TTTS. If it is to be considered for use in clinical practice, a cutoff value of 29% was most predictive of donor twin survival in this cohort and may be useful for preoperative counseling on expected outcomes.

来源:Am J Obstet Gynecol MFM,查看原文。版权归原作者所有。

引用

  1. Rao MG, Gandhi C, Breslin N, et al. Identifying an optimal inter-twin weight discordance cutoff for predicting donor survival after fetoscopic laser surgery for twin-twin transfusion syndrome. Am J Obstet Gynecol MFM. 2026. PMID: 42575370. doi:10.1016/j.ajogmf.2026.102081

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。