文献速递产科母胎医学

基于多部位评估的脐动脉多普勒评分系统与早发型和晚发型胎儿生长受限围产结局的关联

Modified umbilical artery Doppler scoring system based on multisite assessment: association with perinatal outcome in early and late fetal growth restriction.
PubMed 文献 · Ultrasound Obstet Gynecol · 2026-08-25

这项单中心前瞻性队列研究纳入251例符合Delphi共识标准的胎儿生长受限(FGR)单胎妊娠,其中早发型117例、晚发型134例,采用双侧脐动脉六个解剖部位的多普勒评分系统(0-18分)。结果显示,脐动脉多普勒评分≥3分与早发型和晚发型FGR的早产、新生儿重症监护病房(NICU)入住及复合不良围产结局(CAPO)显著相关,且在多因素分析中独立相关。

要点

  • 脐动脉多普勒评分≥3分与早发型和晚发型FGR的CAPO独立相关。
  • 评分升高与胎儿胎盘血流动力学恶化标志物呈线性趋势。
  • 基于分段的双侧脐动脉多普勒评估具有可行性。

核心结论

  • 在早发型或晚发型FGR妊娠中,基于多部位双侧评分系统的较高脐动脉多普勒评分与不良围产结局独立相关。

研究设计与样本

  • 单中心前瞻性队列研究,2025年5月至2025年12月纳入251例符合Delphi共识标准的FGR单胎妊娠,早发型117例、晚发型134例。
  • 从双侧脐动脉的六个预设解剖部位(每侧脐动脉的膀胱周围段、游离环段和胎盘插入点)获取多普勒测量,根据舒张末期血流存在、缺失或反向进行累积评分(0-18分)。

主要发现

  • 脐动脉多普勒评分≥3分在早发型和晚发型FGR中均与早产、NICU入住率升高及CAPO显著相关。
  • 在早发型FGR中,较高评分还与较低出生体重相关。
  • 多因素logistic回归分析显示脐动脉多普勒评分与CAPO独立相关。
  • 随着脐动脉多普勒评分分类(0-2、3-5、6-8、9-12和>12分)增加,CAPO及胎儿胎盘血流动力学恶化个体标志物的发生率呈显著线性趋势。

关键数值与推荐

  • 脐动脉多普勒评分系统累积0-18分,基于双侧脐动脉六个解剖部位的舒张末期血流状态。
  • CAPO定义为新生儿低血糖、需光疗、新生儿脓毒症、呼吸窘迫综合征、需持续气道正压通气、需机械通气、5分钟Apgar评分<7或NICU入住中至少一项发生。
  • 参与者按脐动脉多普勒评分<3分 vs ≥3分进行分层。

临床怎么用

  • 基于多部位双侧脐动脉多普勒评分可用于FGR妊娠的围产结局风险分层。
  • 评分≥3分提示早发型和晚发型FGR的不良围产结局风险增加。

局限性

  • 研究为单中心设计,样本量有限。
  • 需进一步研究确定该评分系统在现有监测策略中应用的临床获益和可行性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

OBJECTIVES: To evaluate a novel bilateral, segment-based umbilical artery (UA) Doppler scoring system in pregnancies complicated by early- or late-onset fetal growth restriction (FGR) and to investigate its association with adverse perinatal outcome. METHODS: This single-center prospective cohort study, conducted between May 2025 and December 2025, included singleton pregnancies diagnosed with FGR according to Delphi consensus criteria. Bilateral UA Doppler measurements were obtained from six predefined anatomical sites: the perivesical segment, the free-loop segment and the placental insertion site in each UA. End-diastolic flow at each site was categorized as present, absent or reversed and incorporated into a cumulative UA Doppler score (0-18 points). Composite adverse perinatal outcome (CAPO) was defined as the occurrence of at least one of the following: neonatal hypoglycemia, need for phototherapy, neonatal sepsis, respiratory distress syndrome, need for continuous positive airway pressure, need for mechanical ventilation, 5-min Apgar score < 7 or admission to the neonatal intensive care unit (NICU). Participants were stratified by UA Doppler score (< 3 vs ≥ 3 points). Multivariable logistic regression analysis was used to assess the association between UA Doppler score as a continuous or dichotomized variable and CAPO, adjusting for maternal age, body mass index, parity, mode of conception, estimated fetal weight percentile and gestational age at delivery. In addition, the prevalence of individual markers of fetoplacental hemodynamic deterioration, including abnormal ductus venosus Doppler, cerebroplacental ratio < 5th percentile, intrauterine fetal demise, fetal distress leading to delivery and 5-min Apgar score < 7, was analyzed across UA Doppler score categories (0-2, 3-5, 6-8, 9-12 and > 12 points). RESULTS: A total of 251 pregnancies with FGR were included, of which 117 were early onset (< 32 weeks' gestation) and 134 were late onset (≥ 32 weeks' gestation). Higher UA Doppler scores (≥ 3 points) were associated significantly with preterm delivery and higher rates of NICU admission and CAPO in both early- and late-onset FGR. In early-onset FGR, higher scores were associated additionally with lower birth weight. The UA Doppler score remained associated independently with CAPO on multivariable logistic regression analysis. A significant linear trend was observed across increasing UA Doppler score categories for the rate of CAPO and individual markers of fetoplacental hemodynamic deterioration. CONCLUSIONS: In pregnancies complicated by early-onset or late-onset FGR, a higher UA Doppler score based on a multisite bilateral scoring system is associated independently with adverse perinatal outcome. These findings support the feasibility of a segment-based approach to UA Doppler assessment. Further studies are required to determine the clinical benefit and feasibility of adoption within current surveillance strategies. © 2026 International Society of Ultrasound in Obstetrics and Gynecology.

来源:Ultrasound Obstet Gynecol,查看原文。版权归原作者所有。

引用

  1. Bulan DD, Bayraktar B, Dayanan R, et al. Modified umbilical artery Doppler scoring system based on multisite assessment: association with perinatal outcome in early and late fetal growth restriction. Ultrasound Obstet Gynecol. 2026. PMID: 42640180. doi:10.1002/uog.70319

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。