足月胎儿EFW低于第10百分位时,估测胎儿体重增长速度对多普勒评估预测围产结局的附加价值
这项回顾性队列研究纳入600例孕32周后诊断EFW低于第10百分位并足月分娩的单胎妊娠,评估基于间隔特异性标准的估测胎儿体重增长速度(GV)能否在标准多普勒和生物测量标准之外额外预测不良围产结局。结果显示慢GV发生率为31.8%,但慢GV组与正常GV组的复合不良结局率无显著差异(22.7% vs 26.6%,p=0.689),且加入慢GV并未改善预测性能(AUC 0.64 vs 0.64,p=0.54)。
要点
- 足月EFW低于第10百分位胎儿中,慢GV发生率为31.8%。
- 慢GV组与正常GV组的复合不良结局率无显著差异。
- 加入慢GV未改善对复合不良结局的预测性能。
核心结论
- 在足月EFW低于第10百分位的胎儿中,慢EFW增长速度不能在已建立的多普勒和生物测量标准之外增强对不良围产结局的预测,其临床效用受到质疑。
研究设计与样本
- 回顾性队列研究,纳入600例孕32周后诊断EFW低于第10百分位并足月分娩的单胎妊娠。
- 在至少两次间隔≥14天的超声检查病例中,根据间隔特异性标准定义诊断小于胎龄儿(SGA)至分娩前最后一次超声之间的EFW增长速度(GV)。
主要发现
- 慢GV发生率为31.8%。
- 慢GV组与正常GV组在母亲特征和诊断时孕周方面无显著差异。
- 最后一次超声时,慢GV组更常见EFW低于第3百分位(52.4% vs 23.2%,p<0.001)和异常脐动脉多普勒(4.2% vs 1.0%,p=0.023)。
- 慢GV组与正常GV组的复合不良结局率无显著差异(22.7% vs 26.6%,p=0.689)。
- 多变量分析中,EFW低于第3百分位、异常子宫动脉搏动指数(UtA-PI)和低脑胎盘比(CPR)是复合不良结局的独立预测因子;加入慢GV未改善预测性能(AUC 0.64 vs 0.64,p=0.54)。
关键数值与推荐
- 胎儿生长受限(FGR)定义为:EFW低于第3百分位,大脑中动脉搏动指数或脑胎盘比(CPR)低于第5百分位,或脐动脉或子宫动脉搏动指数(UtA-PI)≥第95百分位。
- 慢GV定义为根据孕周调整后低于第10百分位。
- 慢GV曾被考虑为检测出生SGA的10%假阳性率阈值,依据已发表参考文献[Hugh O. 2022]。
临床怎么用
- 对于足月EFW低于第10百分位的胎儿,临床应依据已建立的多普勒和生物测量标准(如EFW低于第3百分位、异常UtA-PI、低CPR)评估风险,而非依赖EFW增长速度。
- 慢EFW增长速度不应作为额外预测不良围产结局的常规工具。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
OBJECTIVE: To evaluate whether estimated fetal weight (EFW) growth velocity (GV), assessed using interval-specific standards, provides additional prediction beyond standard criteria for identifying adverse outcomes in term foetuses with EFW < 10th centile. DESIGN: Retrospective cohort study. SETTING: Tertiary perinatal centre. POPULATION: A cohort of 600 singleton pregnancies diagnosed with EFW < 10th above 32 weeks and term delivered. METHODS: GV between the diagnosis of SGA (EFW < 10th centile) and the last ultrasound before delivery was defined according to interval-specific standards in cases with at least two scans ≥ 14 days apart. Slow GV was considered the threshold for a 10% false positive rate for detecting SGA at birth according to published references [Hugh O. 2022]. Fetal growth restriction (FGR) was defined if: EFW < 3rd centile, middle cerebral artery pulsatility index or cerebroplacental ratio (CPR) < 5th centile, or umbilical or uterine artery pulsatility index (UtA-PI) ≥ 95th centile. Slow GV was defined below the 10th centile adjusted for gestational age. Logistic regression analysis was performed. MAIN OUTCOME MEASURES: A composite adverse outcome (CAO) comprising neonatal morbidity or preeclampsia. RESULTS: Slow GV was observed in 31.8% of cases. No significant differences were observed between groups in maternal characteristics, gestational age at diagnosis. At the last scan, foetuses with slow GV more frequently had an EFW < 3rd centile (52.4% vs. 23.2%; p < 0.001) and BW < 3rd centile (51.6% vs. 62.8; p < 0.05) and abnormal umbilical artery Doppler (4.2% vs. 1.0%; p = 0.023). No differences were observed in CAO rates (22.7% vs. 26.6%; p = 0.689). In multivariable analysis, EFW < 3rd centile, abnormal UtA-PI, and low CPR were independent predictors of CAO. Adding slow GV did not improve predictive performance (AUC 0.64 vs. 0.64; p = 0.54). CONCLUSIONS: In term foetuses with EFW < 10th centile, slow EFW GV does not enhance the prediction of adverse perinatal outcomes beyond established Doppler and biometric criteria, questioning its clinical utility.
引用
- Meler E, Gil-Armas C, Moliner M, et al. Added Value of Estimated Fetal Weight Growth Velocity to Doppler Evaluation for the Prediction of Perinatal Outcomes Among Foetuses With EFW < 10th Centile at Term: A Retrospective Cohort Study. BJOG. 2026. PMID: 42644290. doi:10.1111/1471-0528.70324
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。