宫颈阴道液IL-6与胎儿纤连蛋白联合宫颈超声特征预测先兆早产孕妇自发性早产比较
该前瞻性研究纳入249例20-36周先兆早产单胎妊娠孕妇,比较宫颈阴道液IL-6与胎儿纤连蛋白联合宫颈特征预测<37周自发性早产的效能。结果显示宫颈长度联合IL-6的AUC最高(0.78),灵敏度72%、特异度77.2%,阴性预测值96.1%,显著优于胎儿纤连蛋白或单独宫颈长度。
要点
- 宫颈长度联合IL-6预测<37周自发性早产AUC为0.78,阴性预测值96.1%。
- 宫颈长度联合IL-6可替代胎儿纤连蛋白检测用于排除自发性早产。
- 单独IL-6与联合方案预测效能相当,宫颈弹性成像和滑动征无显著差异。
核心结论
- 宫颈长度联合IL-6具有中等灵敏度和高特异度及阴性预测值,可作为<37周自发性早产的排除试验。
- 宫颈长度联合IL-6或单独IL-6可替代胎儿纤连蛋白检测。
研究设计与样本
- 前瞻性研究,纳入249例20-36周先兆早产单胎妊娠孕妇。
- 入院时测量宫颈长度、宫颈弹性成像、宫颈滑动征、宫颈阴道液胎儿纤连蛋白和IL-6。
- 计算单个及联合生物标志物预测<37周自发性早产的效能。
主要发现
- 自发性早产发生率10.04%(25/249)。
- 早产组宫颈长度2.31 cm(1.90-3.18)短于足月组3.41 cm(6.89-11.42),胎儿纤连蛋白100 ng/mL(21.50-461.0)和IL-6 98.63 pg/mL(18.04-258.43)高于足月组7.50 ng/mL(3.00-59.50)和18.41 pg/mL(11.02-38.91),P均<.001。
- 宫颈长度联合IL-6的AUC最高0.78,灵敏度72%、特异度77.2%,阳性预测值26.1%、阴性预测值96.1%,显著优于胎儿纤连蛋白(P=.02)或单独宫颈长度(P=.016),与单独IL-6相当(P=.13)。
- 宫颈弹性成像评分(P=.23)和宫颈滑动征(P=.14)在足月与早产组间无差异。
关键数值与推荐
- 宫颈长度联合IL-6预测<37周自发性早产:AUC 0.78,灵敏度72%,特异度77.2%,阳性预测值26.1%,阴性预测值96.1%。
- 宫颈长度联合IL-6预测效能显著优于胎儿纤连蛋白(P=.02)和单独宫颈长度(P=.016),与单独IL-6无显著差异(P=.13)。
临床怎么用
- 对先兆早产孕妇可检测宫颈长度联合宫颈阴道液IL-6,高阴性预测值有助于排除<37周自发性早产。
- 宫颈长度联合IL-6或单独IL-6可替代已停用的胎儿纤连蛋白检测。
局限性
- 单中心前瞻性研究,样本量有限(249例,早产25例)。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
BACKGROUND: About 80% of patients presenting with threatened preterm labor do not deliver preterm. Currently, cervical length and cervicovaginal fluid fetal fibronectin are tools used to predict spontaneous preterm birth. However, fetal fibronectin testing has been discontinued worldwide. OBJECTIVES: This study aimed to compare the predictive performance of cervicovaginal fluid interleukin-6 (IL-6) and fetal fibronectin, combined with cervical characteristics (cervical length, sliding sign, and elastography) and other maternal characteristics, for predicting spontaneous preterm delivery in patients with threatened preterm labor. METHODS: This was a prospective study involving 249 singleton pregnancies presenting at 20 to 36 weeks with threatened preterm labor. Upon admission, cervical length, cervical elastrography, cervical sliding sign, quantitative cervicovaginal fluid fetal fibronectin, and IL-6 were measured. The predictive performance of individual and combined biomarkers for predicting spontaneous preterm delivery <37 weeks was calculated. RESULTS: The prevalence of spontaneous preterm delivery at <37 weeks of gestation was 10.04% (25/249). The spontaneous preterm delivery group had a significant shorter mean cervical length but higher mean fetal fibronectin and IL-6 concentrations than the term delivery group (cervical length: 2.31 cm [1.90-3.18] vs. 3.41 cm [6.89-11.42]; fetal fibronectin: 100 ng/mL [21.50-461.0] vs. 7.50 ng/mL [3.00-59.50]; IL-6: 98.63 pg/mL [18.04-258.43] vs. 18.41 pg/mL [11.02-38.91]; P<.001 for all). The combination of cervical length and IL-6 yielded the highest AUC of 0.78, with a sensitivity of 72% at a specificity of 77.2%, and positive and negative predictive values of 26.1% and 96.1%, respectively, for predicting spontaneous preterm birth at <37 weeks. Such performance is significantly greater than fetal fibronectin (P=.02) or cervical length alone (P=.016) but comparable to IL-6 alone (P=.13). There are no differences in cervical elastrography score (P=.23) and the presence of cervical sliding sign (P=.14) between term and preterm birth groups. CONCLUSION: In patients with threatened preterm labor symptoms, cervical length in combination with IL-6 had a moderate sensitivity but high specificity and negative predictive value; thus, these tests may be used as a rule-out test for spontaneous preterm delivery <37 weeks. Cervical length, in combination with IL-6, or IL-6 alone, can replace the fibronectin test.
引用
- Chaemsaithong P, Fung JCY, Chen Y, et al. Comparison between cervicovaginal fluid interleukin-6 and fetal fibronectin in combination with cervical ultrasound characteristics for the prediction of spontaneous preterm delivery in threatened preterm labor. Am J Obstet Gynecol MFM. 2026. PMID: 42636976. doi:10.1016/j.ajogmf.2026.102092
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。