指南与共识妇科

经阴道超声诊断子宫腺肌病的准确性:基于共识直接与间接征象的前瞻性队列研究

Diagnostic accuracy of transvaginal ultrasound for adenomyosis using consensus-based direct and indirect sonographic signs: prospective cohort study.
指南 / 共识 · Ultrasound Obstet Gynecol · 2026-08-12

该前瞻性诊断准确性研究纳入345例超声检查后6周内行子宫切除术的女性,以组织病理为参考标准,评估经阴道超声(TVS)基于MUSA共识征象诊断子宫腺肌病的效能。结果显示直接征象中子宫内膜下高回声线平衡最佳(灵敏度53.5%,特异度94.7%),联合直接征象模型特异度高(93.7%)但灵敏度有限(60.0%),加入间接征象无显著增益。

要点

  • 直接征象诊断价值最稳定,间接征象应作为支持而非确诊依据。
  • 子宫内膜下高回声线单项平衡最佳:灵敏度53.5%,特异度94.7%。
  • 联合直接征象模型特异度93.7%,但灵敏度仅60.0%。

核心结论

  • 直接超声征象提供最一致的诊断价值,间接征象应作为支持性而非确定性依据。

研究设计与样本

  • 共2967例TVS评估女性中345例(11.6%)在6周内行子宫切除术构成研究队列,组织病理确诊子宫腺肌病155例(44.9%)。

主要发现

  • 单项超声特征特异度高但灵敏度有限;直接征象中子宫内膜下高回声线平衡最佳,灵敏度53.5%(95%CI 45.4-61.6%),特异度94.7%(95%CI 90.5-97.4%)。
  • 单项间接征象特异度>97%但灵敏度低。
  • 联合直接征象模型特异度93.7%(95%CI 89.2-96.7%),灵敏度60.0%(95%CI 51.8-67.8%),总体诊断准确率78.6%(95%CI 73.8-82.8%)。
  • 将间接征象加入模型未提供有意义的增量获益。

临床怎么用

  • 临床解读TVS时需区分直接与间接征象,直接征象用于诊断决策,间接征象仅作支持参考。
  • 联合直接征象模型特异度高但灵敏度有限,阴性结果不能完全排除子宫腺肌病。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

OBJECTIVE: To evaluate the diagnostic performance of transvaginal ultrasound (TVS) for adenomyosis using consensus-based direct and indirect ultrasound signs, with histopathology as the reference standard. METHODS: This prospective diagnostic accuracy study included women undergoing TVS examination at a tertiary referral center (Hospital San Juan de Dios, Santiago, Chile) between 1 December 2022 and 1 December 2023. Women aged ≥ 18 years who underwent hysterectomy within 6 months after TVS examination were enrolled consecutively. Cases with malignant histopathological findings were excluded. Ultrasound signs of adenomyosis were assessed according to the revised Morphological Uterus Sonographic Assessment consensus. Histopathology served as the reference standard. Diagnostic performance measures for individual ultrasound features and multivariable models were calculated. RESULTS: Among 2967 women evaluated using TVS, 345 (11.6%) underwent hysterectomy within 6 weeks and constituted the study cohort. Histopathology confirmed adenomyosis in 155 (44.9%) women. Individual ultrasound features showed high specificity but limited sensitivity. Among direct signs, echogenic subendometrial lines showed the best overall balance (sensitivity, 53.5% (95% CI, 45.4-61.6%); specificity, 94.7% (95% CI, 90.5-97.4%)). Individual indirect signs showed specificity > 97% but low sensitivity. A model combining direct ultrasound signs showed high specificity (93.7% (95% CI, 89.2-96.7%)) but limited sensitivity (60.0% (95% CI, 51.8-67.8%)); overall diagnostic accuracy was 78.6% (95% CI, 73.8-82.8%). The addition of indirect ultrasound signs into the model did not provide meaningful incremental benefit. CONCLUSIONS: Our findings highlight the importance of distinguishing between direct and indirect ultrasound features, with direct signs providing the most consistent diagnostic value, while indirect signs should be interpreted as supportive rather than definitive. © 2026 International Society of Ultrasound in Obstetrics and Gynecology.

来源:Ultrasound Obstet Gynecol,查看原文。版权归原作者所有。

引用

  1. Morales C, Crovo E, Ebner P, et al. Diagnostic accuracy of transvaginal ultrasound for adenomyosis using consensus-based direct and indirect sonographic signs: prospective cohort study. Ultrasound Obstet Gynecol. 2026. PMID: 42584944. doi:10.1002/uog.70315

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。