文献速递产科母胎医学

第一产程高风险II类电子胎心监护特征是新生儿酸血症的危险因素

High-risk category II electronic fetal monitoring features in the first stage of labor is a risk factor for neonatal acidemia.
PubMed 文献 · Am J Obstet Gynecol MFM · 2026-07-14

本研究为前瞻性队列的二次分析,纳入2010至2015年≥37周单胎分娩且存在高风险II类电子胎心监护特征的患者,比较第一产程与第二产程分娩者的新生儿结局。第一产程分娩者新生儿酸血症风险显著升高(aOR 5.55,95%CI 3.81-8.11),复合新生儿病率亦升高(aOR 2.44,95%CI 1.92-3.09);仅剖宫产亚组分析未见差异但样本量小。

要点

  • 第一产程因高风险II类胎监特征分娩者新生儿酸血症风险显著增高。
  • 该风险在初产妇亚组中同样存在,复合新生儿病率也升高。
  • 仅剖宫产亚组分析未见差异,但受限于样本量小。

核心结论

  • 第一产程高风险II类电子胎心监护特征提示胎儿酸血症风险显著增高,支持据此行第一产程剖宫产的临床逻辑。

研究设计与样本

  • 前瞻性队列研究的二次分析,纳入2010至2015年≥37周单胎分娩,由不知结局的护士提取分娩前60分钟胎监数据。
  • 仅纳入具有高风险II类胎监特征者,比较第一产程分娩588例与第二产程分娩4685例的新生儿结局。

主要发现

  • 第一产程分娩者新生儿酸血症风险显著升高(aOR 5.55,95%CI 3.81-8.11)。
  • 第一产程分娩者复合新生儿病率显著升高(aOR 2.44,95%CI 1.92-3.09),初产妇亚组同样存在。
  • 仅剖宫产亚组(n=737)中,第一产程与第二产程分娩的新生儿酸血症风险无差异(aOR 0.56,95%CI 0.30-1.03)。
  • 仅剖宫产亚组中复合新生儿病率无差异(aOR 0.90,95%CI 0.54-1.45),但样本量小。
  • 第一产程组更常见的高风险胎监特征包括反复变异减速、反复晚期减速和超过1次延长减速。

关键数值与推荐

  • 高风险II类胎监特征定义为至少具备以下一项:反复变异减速、反复晚期减速、超过1次延长减速、心动过速、微小变异或减速总面积≥第75百分位。
  • 新生儿酸血症定义为脐动脉pH≤7.10。

临床怎么用

  • 对第一产程出现高风险II类胎监特征者应警惕新生儿酸血症,及时评估分娩时机。
  • 建议将高风险II类胎监特征纳入II类胎监管理流程图。

局限性

  • 仅剖宫产亚组分析样本量小,结果受限。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

BACKGROUND: High-risk category II electronic fetal monitoring patterns in labor are associated with neonatal acidemia and associated adverse outcomes. However, the impact of the stage of labor at the time of these patterns on neonatal outcomes is unknown. OBJECTIVE: Our objective was to compare neonatal outcomes among patients with high-risk category II electronic fetal monitoring based on the stage of labor at the time of delivery. STUDY DESIGN: We performed a secondary analysis of a prospective cohort study of singleton deliveries at≥37 weeks between 2010 and 2015. Electronic fetal monitoring data were extracted from the 60 minutes before delivery by nurses who were blinded to outcomes. This analysis included only patients with high-risk category II electronic fetal monitoring features, defined as at least one of the following: recurrent variable decelerations, recurrent late decelerations, >1 prolonged deceleration, tachycardia, minimal variability, or total deceleration area ≥75th percentile. The primary outcome was neonatal acidemia, defined as umbilical artery pH ≤7.10. Secondary outcomes included a composite of neonatal morbidity. Outcomes were compared between patients who delivered in the first vs the second stage of labor. A subgroup analysis in nulliparas and a sensitivity analysis of only patients who underwent cesarean delivery (first vs second stage) were performed. Multivariable logistic regression was used to adjust for potential confounders. RESULTS: Of note, 588 patients who underwent cesarean delivery in the first stage of labor were compared with 4685 patients who delivered in the second stage (vaginal and cesarean deliveries). Neonates delivered in the first stage with high-risk category II electronic fetal monitoring had a significantly higher risk of acidemia (adjusted odds ratio, 5.55 [95% confidence interval, 3.81-8.11]) as well as composite neonatal morbidity (adjusted odds ratio, 2.44 [95% confidence interval, 1.92-3.09]), even when the analysis was restricted to nulliparous patients. In a sensitivity analysis including only patients who underwent cesarean delivery (n=737), there was no difference in the risk of neonatal acidemia (adjusted odds ratio, 0.56 [95% confidence interval, 0.30-1.03) or composite neonatal morbidity (adjusted odds ratio, 0.90 [95% confidence interval, 0.54-1.45]) between the group delivered in the first stage and the group delivered in the second stage by cesarean delivery; however, this analysis was limited by a small sample size. Recurrent variable decelerations, recurrent late decelerations, and >1 prolonged deceleration were more frequent high-risk electronic fetal monitoring features in the group delivered in the first stage of labor. CONCLUSION: High-risk category II electronic fetal monitoring features prompting a first-stage cesarean identify a fetal population at significantly higher risk of acidemia, supporting the clinical rationale for performing first-stage cesareans in response to these electronic fetal monitoring features. These findings suggest that high-risk category II electronic fetal monitoring features should be incorporated into flow diagrams for category II electronic fetal monitoring management.

来源:Am J Obstet Gynecol MFM,查看原文。版权归原作者所有。

引用

  1. Chaffay J, Woolfolk C, Kelly JC, et al. High-risk category II electronic fetal monitoring features in the first stage of labor is a risk factor for neonatal acidemia. Am J Obstet Gynecol MFM. 2026. PMID: 42448228. doi:10.1016/j.ajogmf.2026.102058

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。