孕期磁共振成像评估宫颈长度:与经阴道超声的相关性及一致性
该回顾性横断面研究纳入100例同日接受胎儿MRI与经阴道超声的孕妇,评估MRI与超声测量宫颈长度的相关性与一致性。结果显示两者强相关(r=0.775),MRI诊断孕中期短宫颈的敏感度100%、特异度94.6%,提示MRI可辅助排除短宫颈,但超声仍是金标准。
要点
- 胎儿MRI与经阴道超声测量的宫颈长度强相关(r=0.775)。
- MRI宫颈长度≤25mm预测超声短宫颈的敏感度100%、特异度94.6%。
- MRI可用于因其他指征行MRI者排除短宫颈,超声仍为首选。
核心结论
- 胎儿MRI测量的宫颈长度与经阴道超声相关,可辅助排除孕期短宫颈,但超声仍是金标准。
主要发现
- MRI与超声宫颈长度强相关(r=0.775;P<0.001),在BMI、单胎/多胎及超声宫颈长度分层中均显著。
- Bland-Altman分析显示MRI与超声宫颈长度平均差异为-0.97mm(95%一致性界限-13.67至11.73mm)。
- 孕中期MRI宫颈长度≤25mm预测超声宫颈长度<25mm的敏感度100%(95%CI 59.0-100%)、特异度94.6%(95%CI 86.9-98.5%)、阳性预测值63.6%(95%CI 30.8-89.1%)、阴性预测值100%(95%CI 94.9-100%)。
关键数值与推荐
- 孕中期MRI宫颈长度≤25mm预测超声短宫颈的敏感度100%、特异度94.6%、阳性预测值63.6%、阴性预测值100%。
- MRI与超声宫颈长度平均差异-0.97mm,95%一致性界限-13.67至11.73mm。
临床怎么用
- 对因其他指征行胎儿MRI的孕妇,可参考MRI宫颈长度排除短宫颈,但确诊仍需经阴道超声。
局限性
- 回顾性单中心研究,样本量100例,需更大研究验证。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
OBJECTIVE: To assess the correlation between cervical length (CL) measurements obtained via fetal magnetic resonance imaging (MRI) and transvaginal ultrasound (TVS), and the accuracy of CL measurements obtained via MRI in diagnosing a second-trimester short cervix, using TVS as the gold standard. METHODS: This was a retrospective cross-sectional study of pregnancies referred to our center between January 2022 and December 2024 that underwent fetal MRI and TVS examination on the same day. We estimated the correlation between MRI- and TVS-derived CL measurements using Spearman's rank correlation coefficient, with stratified analysis by pertinent clinical variables. Bland-Altman analysis was used to evaluate the agreement between the two imaging methods. Finally, for the subset of patients examined in the second trimester, we calculated the sensitivity, specificity, positive predictive value (PPV) and negative predictive value (NPV) of CL ≤ 25 mm on fetal MRI for predicting a short cervix with CL < 25 mm on TVS. RESULTS: We screened 132 patients, of whom 31 were excluded owing to incomplete data and one was excluded due to having a cervical cerclage in place. Therefore, 100 patients were included for analysis. There was a strong correlation between MRI- and TVS-derived CL measurements (r = 0.775; P < 0.001), which remained significant regardless of maternal body mass index, pregnancy type (singleton vs multiple) and CL on TVS (< 25 mm vs ≥ 25 mm). According to the Bland-Altman analysis, the mean difference in CL measurements between MRI and TVS was -0.97 (95% limits of agreement, -13.67 to 11.73) mm. The sensitivity, specificity, PPV and NPV of MRI-derived CL ≤ 25 mm for predicting a short cervix on TVS in the second trimester were 100% (95% CI, 59.0-100%), 94.6% (95% CI, 86.9-98.5%), 63.6% (95% CI, 30.8-89.1%) and 100% (95% CI, 94.9-100%), respectively. CONCLUSIONS: CL measurements obtained using fetal MRI correlate with those obtained using TVS. MRI-derived CL estimates may help to exclude a short cervix during pregnancy in selected patients undergoing MRI for other indications. However, larger studies are needed to validate our findings, and TVS remains the gold standard for cervical assessment during pregnancy. © 2026 International Society of Ultrasound in Obstetrics and Gynecology.
引用
- Schenone CV, Fadiloglu E, Sambatur E, et al. Cervical length assessment using magnetic resonance imaging during pregnancy: correlation and agreement with transvaginal ultrasound. Ultrasound Obstet Gynecol. 2026. PMID: 42430210. doi:10.1002/uog.70269
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。