术前超声滑动膀胱征预测子宫切除术中膀胱-子宫粘连

Predicting bladder-to-uterine adhesions in patients undergoing hysterectomy using sliding-bladder sign technique with preoperative ultrasound: a diagnostic accuracy study.
PubMed 文献 · Ultrasound Obstet Gynecol · 2026-07-10

一项前瞻性诊断准确性研究纳入128例因良性妇科疾病计划行腹腔镜子宫切除术的患者,术前经阴道超声评估滑动膀胱征,以术中确认膀胱-子宫粘连为参考标准。滑动膀胱征诊断准确率89.1%,敏感性69.4%,特异性96.7%,阳性似然比21.3,阴性似然比0.3。

要点

  • 滑动膀胱征特异性高达96.7%,阳性似然比21.3,阳性时粘连可能性大。
  • 敏感性69.4%,阴性似然比0.3,阴性时仍不能完全排除粘连。
  • 该征象无创,可纳入术前超声评估以预判前腔粘连。

核心结论

  • 经阴道超声评估滑动膀胱征是无创预测膀胱-子宫粘连的工具,膀胱滑动消失时结果可靠。

主要发现

  • 128例中28.1%术中确认存在膀胱-子宫粘连。
  • 滑动膀胱征诊断准确率89.1%(95%CI 82.3-93.9%)。
  • 敏感性69.4%(95%CI 51.9-83.6%),特异性96.7%(95%CI 90.1-99.3%)。
  • 阳性预测值89.3%(95%CI 72.8-96.3%),阴性预测值89.0%(95%CI 83.2-93.0%)。
  • 阳性似然比21.3(95%CI 6.8-66.2),阴性似然比0.3(95%CI 0.2-0.5)。

临床怎么用

  • 可将滑动膀胱征纳入术前经阴道超声检查,帮助预判前腔粘连并做好围手术期准备。
  • 该征象特异性高,阳性时提示粘连可能性大;敏感性中等,阴性时不能完全排除粘连。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

OBJECTIVE: This study aimed to determine the accuracy of the sliding-bladder sign assessed using preoperative transvaginal ultrasound (TVS) for identifying the presence of bladder-to-uterine (BTU) adhesions in patients undergoing hysterectomy. METHODS: This was a prospective diagnostic test-accuracy study conducted at Hamilton Health Sciences, Hamilton, ON, Canada. Patients scheduled for a planned laparascopic hysterectomy for a benign gynecological condition between October 2021 and December 2024 were included and all underwent preoperative TVS examination that included assessment of the sliding-bladder sign. The presence of BTU adhesions was assessed using TVS (index test) and confirmed at hysterectomy (reference standard) by independent assessors who were blinded to the outcome of the other test. The accuracy, specificity, sensitivity, positive and negative predictive values and positive and negative likelihood ratios of the sliding-bladder sign were calculated. RESULTS: Of 128 included women, 28.1% had BTU adhesions confirmed at hysterectomy. The sliding-bladder sign on preoperative TVS demonstrated an accuracy of 89.1% (95% CI, 82.3-93.9%), with a sensitivity of 69.4% (95% CI, 51.9-83.6%) and a specificity of 96.7% (95% CI, 90.1-99.3%). The positive predictive value was 89.3% (95% CI, 72.8-96.3%), while the negative predictive value was 89.0% (95% CI, 83.2-93.0%). The positive likelihood ratio was 21.3 (95% CI, 6.8-66.2) and the negative likelihood ratio was 0.3 (95% CI, 0.2-0.5). CONCLUSIONS: The sliding-bladder sign assessed using TVS is a non-invasive tool for predicting the presence of BTU adhesions that is reliable when bladder sliding is absent. Incorporating this assessment into preoperative ultrasound examinations may support anatomical anticipation of anterior-compartment adhesions and perioperative preparedness as part of a comprehensive evaluation. © 2026 The Author(s). Ultrasound in Obstetrics & Gynecology published by John Wiley & Sons Ltd on behalf of International Society of Ultrasound in Obstetrics and Gynecology.

来源:Ultrasound Obstet Gynecol,查看原文。版权归原作者所有。

引用

  1. van Keizerswaard J, Freger SM, Mick I, et al. Predicting bladder-to-uterine adhesions in patients undergoing hysterectomy using sliding-bladder sign technique with preoperative ultrasound: a diagnostic accuracy study. Ultrasound Obstet Gynecol. 2026. PMID: 42427219. doi:10.1002/uog.70281

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。