文献速递妇科生殖医学

经阴道超声检测盆腔游离液作为经血逆流替代标志物的研究

Free pelvic fluid detection and quantification using transvaginal ultrasound: a surrogate marker for retrograde menstruation.
PubMed 文献 · Reprod Biomed Online · 2026-03-01

前瞻性单中心队列纳入102名女性,在同一自然周期第2-3天和第7-10天行经阴道超声测量盆腔游离液体积。月经期检出率71.6%,增殖期中晚期44.1%,体积从1.0ml降至0ml,且随月经量增多而增加。提示盆腔游离液可作为经血逆流的无创替代标志物。

要点

  • 月经期盆腔游离液检出率71.6%,增殖期中晚期降至44.1%。
  • 可测量游离液者中73%周期内体积变化为正,月经期体积高于增殖期。
  • 月经期游离液>1ml的比例随月经量增多而升高(稀少0%、正常43.9%、大量60.7%)。

核心结论

  • 经阴道超声可检测并量化盆腔游离液,其周期内变化支持其作为经血逆流的替代标志物。

研究设计与样本

  • 前瞻性观察性单中心队列研究,纳入102名女性,在同一自然月经周期第2-3天和第7-10天行标准化经阴道超声检查。

主要发现

  • 月经期盆腔游离液检出率71.6%(95%CI 61.8-80.1%),增殖期中晚期44.1%(95%CI 34.3-54.3%),P<0.001。
  • 可测量游离液的73名女性中,周期内体积变化为正者占73%(95%CI 61.4-82.7%),P<0.001。
  • 游离液体积中位数从月经期1.0ml(IQR 0.3-3.2)降至增殖期0ml(IQR 0-0.6),P<0.001。
  • 月经期游离液>1ml在月经量稀少、正常和大量者中分别占0%(0/4)、43.9%(18/41)和60.7%(17/28),P=0.03。

关键数值与推荐

  • 盆腔游离液体积采用椭球公式计算,并计算周期内变化值(ΔVRM)。

临床怎么用

  • 经阴道超声测量盆腔游离液可作为评估经血逆流的无创方法,尤其适用于月经期检查。

局限性

  • 单中心研究,样本量有限,月经量稀少亚组仅4例。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

RESEARCH QUESTION: Can transvaginal ultrasonography (TVUS) reliably detect and quantify free pelvic fluid (FPF) as a surrogate marker of retrograde menstruation, and how do its volume and characteristics vary across menstrual phases, characteristics and gynaecological conditions? DESIGN: Prospective, observational, single-centre cohort study at a tertiary infertility centre. Women underwent two standardized TVUS examinations within the same natural menstrual cycle: on day 2-3 (menstrual phase) and day 7-10 (medium-late proliferative phase). FPF volume was measured using the ellipsoid formula, and within-cycle changes (ΔVRM) were calculated. The primary outcome was the presence and extent of FPF and within-cycle FPF changes, and the secondary outcome was menstrual-phase FPF changes across menstrual blood loss (MBL) categories. RESULTS: In total, 102 women were included in this study. FPF was detected in 71.6% (95% CI 61.8-80.1%) on day 2-3 and in 44.1% (95% CI 34.3-54.3%) on day 7-10 (P < 0.001). Among women with measurable FPF (n = 73), ΔVRM was positive in 73% (95% CI 61.4-82.7%; P < 0.001), significantly different from the 50% expected under no within-cycle difference. Median FPF volume declined from 1.0 ml (IQR 0.3-3.2) ml in the menstrual phase to 0 ml (IQR 0-0.6 ml) in the proliferative phase (P < 0.001). Menstrual FPF >1 ml was observed in 0% (0/4), 43.9% (18/41) and 60.7% (17/28) of women with scanty, normal and heavy MBL, respectively (P = 0.03). CONCLUSION: Menstrual FPF was detected in over two-thirds of women, with within-cycle volumetric changes, wide variability between women, and increasing magnitude with heavier MBL. These findings suggest that, using FPF as a surrogate marker, retrograde menstruation may be identified and quantified using a simple non-invasive TVUS-based method. This work offers a potential methodological framework for studying menstrual physiology.

来源:Reprod Biomed Online,查看原文。版权归原作者所有。

引用

  1. Salmeri N, Viganò P, Reschini M, et al. Free pelvic fluid detection and quantification using transvaginal ultrasound: a surrogate marker for retrograde menstruation. Reprod Biomed Online. 2026. PMID: 42202667. doi:10.1016/j.rbmo.2026.105664

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。