宫内节育器深嵌肌层:手术处理与技术策略的视频描述
本文通过两例宫内节育器(IUD)深嵌肌层的病例,描述手术处理及技术策略。第一例IUD近浆膜层,采用宫腔镜联合腹腔镜监视下电外科与机械工具取出;第二例IUD嵌于肌层但未近浆膜,仅宫腔镜电外科扩大通道后取出。强调术前超声评估嵌入深度及与浆膜距离以决定是否需腹腔镜辅助,电外科有用但深部操作机械工具更精准。
要点
- 术前超声评估IUD嵌入深度及与浆膜距离,决定是否需腹腔镜辅助。
- 近浆膜层嵌入时,腹腔镜监视下联合电外科与机械工具可降低穿孔风险。
- 深部肌层操作时机械工具比电外科更精准,电外科可用于扩大通道。
核心结论
- IUD深嵌肌层可增加取出难度及相关并发症风险,需根据术前超声评估制定个体化手术策略。
研究设计与样本
- 两例病例报告,描述IUD深嵌肌层的手术处理及技术策略,来自三级转诊医院。
主要发现
- 第一例IUD深嵌于右侧宫角区,5 Fr抓钳取出失败,需在腹腔镜监视下用5 Fr针尖电极和剪刀行肌层切开,再用5 Fr tenaculum取出。
- 第二例IUD嵌于后壁,用电外科器械扩大通道后直视下轻柔取出,无需腹腔镜辅助。
关键数值与推荐
- 第一例术前2D/3D超声显示IUD深嵌于右侧宫角区,宫腔镜确认部分嵌入,需先切除子宫内膜息肉。
- 第二例超声显示IUD嵌于后壁(峡部),未紧贴浆膜,穿孔风险低,故未行腹腔镜辅助。
临床怎么用
- 术前超声应评估IUD嵌入深度及与浆膜的距离,近浆膜或疑有穿孔风险时考虑腹腔镜监视。
- 深部肌层操作优先使用机械工具(如5 Fr剪刀、tenaculum)以提高精准性,电外科可用于扩大通道。
局限性
- 仅两例病例报告,经验有限,需进一步研究标准化处理方案。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
OBJECTIVE: To describe the management of two cases of intrauterine devices (IUDs) deeply embedded within the myometrium, illustrating the surgical techniques used and the rationale for combined approaches. SETTING: Tertiary referral hospital. PARTICIPANTS: Two patients referred after recent IUD placement with pelvic pain and abnormal uterine bleeding. INTERVENTION: In the first case, 2D/3D ultrasound revealed an IUD deeply embedded in the right cornual area. Diagnostic hysteroscopy performed with a rigid continuous-flow hysteroscope and saline-solution confirmed partial embedding; an endometrial polypectomy was required before removal. Attempts to remove the IUD with 5 Fr grasping forceps - a miniaturized retrieval instrument - failed, necessitating careful myometrial dissection using 5 Fr needle-tip electrodes - powered by radiofrequency electrical energy (Versapoint, Ethicon) - and 5 Fr scissors under continuous laparoscopic-guidance. A 5 Fr tenaculum was then used for extraction, and final laparoscopic inspection confirmed serosal integrity. In the second case, ultrasound demonstrated an IUD embedded in the posterior wall. Incisions performed with electrosurgical instruments enlarged the access tract, enabling gentle extraction under direct vision. CONCLUSION: IUD embedment within the myometrium may complicate device removal and be associated with complications. Preoperative ultrasound is essential to assess device depth and proximity to the serosa. In the first case, the IUD appeared to be in close proximity to the serosa; given the concern for potential injury within the infraligamentary region, including uterine perforation and possible vascular or adjacent organ damage, a precautionary laparoscopic guidance was preferred. In the second case, laparoscopic assistance was not required, as ultrasound demonstrated an IUD embedded in the isthmic portion without close contact with the serosa, and the risk of perforation was therefore considered low. Electrosurgery is a useful equipment, but mechanical tools are preferable when working deep within the myometrium, as they allow more precise movements. Further studies are needed to standardize management. VIDEO ABSTRACT.
引用
- Borrelli D, Zizolfi B, De Angelis MC, et al. Intrauterine Devices Deeply Embedded within the Myometrium: Video-Based Description of Surgical Management and Technical Strategies. J Minim Invasive Gynecol. 2026. PMID: 41921605. doi:10.1016/j.jmig.2026.03.031
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。