冻融胚胎移植方案与胎盘植入谱系风险及机构差异
日本全国性横断面研究分析2020-2022年38973例冻融胚胎移植分娩,比较程序化周期FET与自然周期FET的胎盘植入谱系(PAS)风险,并评估机构PC-FET使用比例的影响。结果显示PC-FET与PAS及严重PAS风险显著升高相关,高比例使用PC-FET的机构PAS风险也更高。
要点
- 程序化周期FET较自然周期FET显著增加PAS风险(OR 5.02)。
- 程序化周期FET也增加严重PAS风险(OR 5.36)。
- 高比例使用PC-FET的机构PAS风险更高(OR 1.36)。
核心结论
- 程序化周期冻融胚胎移植增加胎盘植入谱系风险。
- 机构层面PC-FET使用比例高与PAS风险升高相关。
研究设计与样本
- 日本全国性横断面研究,分析2020-2022年围产登记库中38973例冻融胚胎移植分娩,并与2019-2022年辅助生殖技术登记库链接。
- 主要暴露为PC-FET versus NC-FET,机构按PC-FET比例三分位分层。
- 采用稳定逆概率治疗加权和多变量回归估计OR及95%CI。
主要发现
- PC-FET组PAS发生率3.6%,NC-FET组0.7%(OR 5.02,95%CI 3.87-6.53)。
- PC-FET组严重PAS发生率1.5%,NC-FET组0.3%(OR 5.36,95%CI 3.51-8.20)。
- 高比例PC-FET机构较低比例机构PAS风险更高(OR 1.36,95%CI 1.16-1.58),严重PAS风险也更高(OR 1.34,95%CI 1.07-1.70)。
关键数值与推荐
- PAS定义为临床或病理诊断。
- 严重PAS定义为PAS伴出血>2000 ml或需球囊填塞、压迫缝合、栓塞或围产期子宫切除。
临床怎么用
- 对程序化周期FET妊娠应提高PAS警惕并加强产前评估。
- 机构层面PC-FET使用比例高可能提示PAS风险增加,需关注机构实践差异。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
RESEARCH QUESTION: Does programmed cycle frozen embryo transfer (PC-FET) increase the risk of placenta accreta spectrum (PAS) compared with natural cycle FET (NC-FET), and does this risk vary according to facility-level utilization of PC-FET? DESIGN: This nationwide, cross-sectional study analysed 38,973 frozen embryo transfer deliveries identified in the Japanese perinatal registry database (2020-2022), linked to the assisted reproductive technology registry database (2019-2022). The primary exposure was PC-FET versus NC-FET. Facilities were stratified into tertiles based on the proportion of PC-FET (low, medium and high). The primary outcome was PAS, defined as either clinical or pathological. Morbid PAS was defined as PAS accompanied by haemorrhage >2000 ml or managed with balloon tamponade, compression sutures, embolization, or peripartum hysterectomy. OR and 95% CI were estimated with stabilized inverse probability of treatment weighting and multivariable regression. RESULTS: PAS occurred in 3.6% and 0.7% of PC-FET and NC-FET deliveries, respectively (OR 5.02, 95% CI 3.87-6.53). Morbid PAS occurred in 1.5% and 0.3% of PC-FET and NC-FET deliveries, respectively (OR 5.36, 95% CI 3.51-8.20). Facilities with a high proportion of PC-FET had a higher risk of PAS (OR 1.36, 95% CI 1.16-1.58) and morbid PAS (OR 1.34, 95% CI 1.07-1.70) compared with facilities with a low proportion of PC-FET. CONCLUSIONS: This study provides robust evidence that PC-FET increases the risk of PAS. Further research should explore the association between facility variations and the incidence of PAS.
引用
- Sugai S, Tatsumi T, Ogawa K, et al. Impact of frozen embryo transfer on placenta accreta and institutional variations. Reprod Biomed Online. 2025. PMID: 41865502. doi:10.1016/j.rbmo.2025.105419
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。