文献速递妇科生殖医学

宫腔镜诊断慢性子宫内膜炎的准确性:系统综述与潜类别荟萃分析

Diagnostic Accuracy of Hysteroscopy for Chronic Endometritis in Reproductive-Age and Infertile Women: A Systematic Review and Latent Class Meta-Analysis.
PubMed 文献 · J Minim Invasive Gynecol · 2026-02-11

该研究通过贝叶斯潜类别荟萃分析评估宫腔镜诊断慢性子宫内膜炎的准确性,纳入28项研究,以病理、免疫组化或微生物学为不完美参考标准。汇总敏感度为0.816(95%CI: 0.728-0.882),特异度为0.806(0.729-0.871),诊断比值比为18.895(9.364-39.832)。结论支持宫腔镜作为临床评估和治疗规划中可靠的初诊工具。

要点

  • 宫腔镜诊断慢性子宫内膜炎汇总敏感度0.816,特异度0.806。
  • 诊断比值比18.895,提示诊断性能较高。
  • 苏木精-伊红染色是最准确的参考标准。

核心结论

  • 宫腔镜在不完美参考标准下对慢性子宫内膜炎具有高诊断性能,证据支持其作为可靠的初诊工具。

研究设计与样本

  • 系统综述与贝叶斯潜类别荟萃分析,纳入28项研究(12项诊断准确性研究、5项队列研究、11项病例系列)。
  • 检索截至2025年10月1日,不限语言,使用QUADAS-2评估研究质量。

主要发现

  • 宫腔镜汇总敏感度为0.816(95%CI: 0.728-0.882)。
  • 宫腔镜汇总特异度为0.806(95%CI: 0.729-0.871)。
  • 诊断比值比为18.895(95%CI: 9.364-39.832)。
  • 苏木精-伊红染色是最准确的参考标准。
  • 亚组和敏感性分析证实结果在生殖障碍人群和低偏倚研究中一致,估计报告偏倚风险低。

临床怎么用

  • 宫腔镜可作为慢性子宫内膜炎临床评估和治疗规划的可靠初诊工具。

局限性

  • 模型基于不完美参考标准,存在基于模型的局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

OBJECTIVE: To evaluate the diagnostic accuracy of hysteroscopy for chronic endometritis (CE) in reproductive-aged women, including those with infertility or recurrent pregnancy loss, considering histopathological, immunohistochemical, and microbiological tests as imperfect reference standards through a Bayesian latent class meta-analysis. DATA SOURCES AND METHOD OF STUDY SELECTION: We included peer-reviewed diagnostic accuracy studies, cohort studies, and case series that assessed hysteroscopy as the index test for CE. Eligible studies applied histopathological, immunohistochemical, or microbiological reference standards to endometrial, endocervical, or vaginal samples, providing sufficient quantitative data. Searches across common databases and registries up to October 1st, 2025, were not restricted by language. Study quality was assessed using QUADAS-2. TABULATION AND INTEGRATION: Pooled estimates of sensitivity, specificity, diagnostic odds ratio (DOR), and likelihood ratios (LR) were obtained using an imperfect-standards Bayesian latent class meta-analysis approach. Subgroup and sensitivity analyses were performed regarding the profile of the studied populations and the risk of bias within and across the studies. RESULTS: The 28 included studies (12 diagnostic accuracy, 5 cohort, 11 case series) yielded pooled hysteroscopy results of 0.816 sensitivity (95% CI: 0.728-0.882), 0.806 specificity (0.729-0.871), and a DOR of 18.895 (9.364-39.832). Hematoxylin-eosin staining was the most accurate reference standard. Subgroup and sensitivity analyses confirmed results consistency across reproductive-disorder populations and lower-bias studies, with a low estimated risk of reporting bias. CONCLUSION: Hysteroscopy demonstrates high diagnostic performance for CE when compared against imperfect reference standards. Despite model-based limitations, evidence supports hysteroscopy as a reliable primary diagnostic tool in clinical assessment and treatment planning. REGISTRATION: PROSPERO registration number: CRD420251087545.

来源:J Minim Invasive Gynecol,查看原文。版权归原作者所有。

引用

  1. Pérez Milán F, Caballero Campo M, Domínguez Arroyo JA, et al. Diagnostic Accuracy of Hysteroscopy for Chronic Endometritis in Reproductive-Age and Infertile Women: A Systematic Review and Latent Class Meta-Analysis. J Minim Invasive Gynecol. 2026. PMID: 41688012. doi:10.1016/j.jmig.2026.02.021

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。