自采阴道与尿液样本用于HPV检测的质量与适用性评估
结果显示干式自采样在室温储存2周内DNA质量与湿式样本无显著差异,尿液样本HPV阳性率较低且Ct值较高。
要点
- 干式FLOQSwab阴道自采样室温储存2周内DNA质量与湿式样本相当。
- 尿液样本HPV阳性率低于其他样本类型,HPV Ct值更高。
- 干式自采样配合BD Onclarity检测可能具有足够DNA质量与准确性。
核心结论
- 诊所采集的Copan FLOQSwab干式自采样在室温储存至多2周后重悬,使用BD Onclarity检测时DNA质量与准确性可能足够,与湿式自采样及医生采集样本相当。
- 使用Colli-pee装置的尿液样本对HPV检测的敏感性可能低于医生采集的宫颈样本。
研究设计与样本
- 每位参与者提供首段尿液(10 mL/20 mL,Collipee)、两份阴道自采样(Copan FLOQSwab干式与湿式转运)及一份医生采集的宫颈样本。
- 样本立即处理或室温储存1周或2周后处理,HPV检测使用BD Onclarity。
主要发现
- 干式与湿式样本在2周内重悬时DNA质量无显著降低:中位GQS干式vs湿式分别为立即3.35 vs 3.41、1周3.00 vs 3.14、2周3.45 vs 2.78,所有单侧p>0.05。
- 尿液样本HPV阳性率低于其他样本类型,且HPV Ct值更高(中位30 vs 干式/湿式/医生样本27)。
临床怎么用
- 干式阴道自采样可在室温储存至多2周后重悬,用于BD Onclarity HPV检测。
- 尿液样本(Colli-pee装置)HPV检测敏感性可能较低,临床选择样本类型时需考虑。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
OBJECTIVE: To evaluate the analytical suitability of different storage and laboratory processes of self-samples for an HPV assay. DESIGN: Prospective matched study. SETTING: Royal London Hospital Colposcopy Clinic. POPULATION: One hundred seventy seven patients aged 25-65 years referred to colposcopy due to their screening results (abnormal cytology or recurrent HPV infection). METHODS: Each participant provided a first void urine sample (10 mL/20 mL, Collipee), two vaginal self-samples (Copan FLOQSwabs transported 'dry' and 'wet'), and a clinician-collected cervical sample. Samples were processed immediately or after 1 or 2 weeks stored at room temperature. HPV testing used BD Onclarity. MAIN OUTCOME MEASURES: Genomic DNA Quality Score (GQS), detection of HPV, and HPV cycle threshold (Ct) values. RESULTS: DNA quality of dry samples was not significantly lower than wet samples when resuspended within 2 weeks (median GQS dry vs. wet: 3.35 vs. 3.41, immediately; 3.00 vs. 3.14, 1 week; 3.45 vs. 2.78, 2 weeks; all p [one-sided] > 0.05). Urine samples had lower HPV positivity compared to other sample types and had higher HPV Ct values (median 30 vs. 27 for dry/wet/clinician samples). CONCLUSION: Dry self-samples from a Copan FLOQSwab taken in clinic are likely to have sufficient DNA quality and accuracy for HPV testing compared with wet self-samples and clinician-collected samples if resuspension takes place up to 2 weeks, with storage at room temperature, and using the BD Onclarity assay. Urine samples using the Colli-pee device are likely to be less sensitive for HPV detected from clinician-collected samples.
引用
- Chu K, Vidali S, Parberry A, et al. Evaluation of the Quality and Suitability of Self-Collected Vaginal and Urine Samples for Human Papillomavirus Testing: A Prospective Matched Study. BJOG. 2026. PMID: 41639581. doi:10.1111/1471-0528.70170
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。