文献速递妇科生殖医学

光学流运动量化分析子宫腺肌症患者的子宫蠕动

Quantitative analysis of uterine peristalsis in women with adenomyosis using optical flow for motion quantification.
PubMed 文献 · Reprod Biomed Online · 2025-05-30

这项前瞻性观察队列研究纳入中度至重度子宫腺肌症女性(n=26)与子宫正常女性(n=40),在辅助生殖周期中行经阴道超声(TVS)检查(共143次记录),用光学流分析拟合二维波动方程计算蠕动频率、幅度与协调性。结果显示腺肌症组在IVF周期各时间点的拟合误差均显著更高,提示蠕动协调性下降;观察者间与观察者内一致性为中等至良好。

要点

  • 腺肌症患者在IVF周期基线、促排卵及移植日的子宫蠕动协调性均低于正常子宫女性。
  • 光学流分析拟合二维波动方程可客观量化TVS下的子宫蠕动频率、幅度与协调性。
  • 该方法观察者间与观察者内一致性为中等至良好,具备在辅助生殖与妇科推广的潜力。

核心结论

  • 光学流分析可用于经阴道超声下客观、可重复地量化子宫蠕动,腺肌症女性整个IVF周期的子宫蠕动协调性均低于正常子宫女性。

研究设计与样本

  • 前瞻性观察队列研究,纳入中度至重度子宫腺肌症女性n=26与子宫正常女性n=40,均在接受辅助生殖期间行TVS。
  • 共采集TVS记录n=143,时间点为基线、卵巢刺激第6-10天及胚胎移植日,先由操作者A完成,再由操作者A、B或C重复。
  • 图像数据离线存储后进行光学流分析,以子宫内膜-肌层交界处像素级位移拟合二维波动方程计算蠕动频率与幅度,拟合误差作为波动协调性的度量。
  • 计算组内相关系数(ICC)评估观察者间与观察者内一致性。

主要发现

  • 腺肌症组在IVF周期各时间点的拟合误差均显著高于正常子宫组:基线+0.725(P<0.001)、卵巢刺激期+0.612(P=0.004)、胚胎移植日+0.627(P<0.001)。
  • 拟合误差升高提示腺肌症女性子宫蠕动协调性低于正常子宫女性。
  • 各波动特征(蠕动频率、幅度、协调性及肌层收缩力)的观察者内ICC为0.62-0.75,观察者间ICC为0.58-0.79,一致性为中等至良好。

关键数值与推荐

  • 腺肌症组与正常子宫组的拟合误差差值:基线+0.725(P<0.001)、卵巢刺激期+0.612(P=0.004)、胚胎移植日+0.627(P<0.001)。
  • 观察者内ICC 0.62-0.75,观察者间ICC 0.58-0.79。

临床怎么用

  • 可在辅助生殖周期中用TVS结合光学流分析客观评估子宫蠕动协调性,作为腺肌症患者子宫功能评估的潜在工具。
  • 测量结果需注意观察者间一致性仅为中等至良好,重复测量时宜固定操作流程。

局限性

  • 研究为观察性设计,样本量有限(腺肌症n=26、正常子宫n=40)。
  • 光学流分析基于离线图像数据,尚未在更广泛人群与临床场景中验证。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

RESEARCH QUESTION: Do women with adenomyosis have altered uterine peristalsis, and can an objective and reproducible tool be developed to quantify uterine peristalsis on transvaginal sonography (TVS)? DESIGN: Prospective observational cohort study in women with moderate to severe adenomyosis (n = 26) or a normal uterus (n = 40) undergoing TVS during assisted conception. TVS recordings (n = 143) were conducted at baseline, day 6-10 of ovarian stimulation and day of embryo transfer by operator A, and then repeated by operator A, B or C. Image data were stored offline for optical flow analysis. Pixel-level displacements for points at the endometrial--myometrial junction were used to compute peristalsis frequency and amplitude by fitting to the two-dimensional wave equation. Fit error was taken as a measure of wave coordination. Inter-class correlation coefficient (ICC) was calculated to assess inter- and intra-observer agreement. RESULTS: Women with adenomyosis had a significantly higher fit error at all time points during the IVF cycle (baseline: + 0.725, P < 0.001; ovarian stimulation: + 0.612, P = 0.004; embryo transfer: + 0.627, P < 0.001), indicating lower uterine peristalsis coordination compared with women with a normal uterus. Inter- and intra-observer agreement for each wave feature (frequency, amplitude and coordination of uterine peristalsis and myometrial contractility) was found to be moderate to good (intra-observer ICC: 0.62-0.75, inter-observer ICC: 0.58-0.79). CONCLUSION: An objective and reproducible measuring tool is proposed to quantify uterine peristalsis using TVS, with potential for wide application across assisted conception and gynaecology settings.

来源:Reprod Biomed Online,查看原文。版权归原作者所有。

引用

  1. Latif S, Saeed SU, Hu Y, et al. Quantitative analysis of uterine peristalsis in women with adenomyosis using optical flow for motion quantification. Reprod Biomed Online. 2025. PMID: 41713072. doi:10.1016/j.rbmo.2025.105073

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。