盆腔MRI三维建模用于深部子宫内膜异位症的可行性研究
本研究回顾性分析147例经手术确诊的深部子宫内膜异位症(DE)患者,其中41例MRI数据集成功完成三维重建。专家评价认为模型附加价值为中等至显著,三维建模在48%病例中改善病灶可视化、67%确认手术策略、8%修改策略。结论认为大规模三维建模技术可行且被认为有益,主要价值在于术前规划、手术教学和患者沟通。
要点
- 147例中41例MRI数据集可完成三维重建,技术可行。
- 三维建模在48%病例改善病灶可视化,67%确认手术策略。
- 主要障碍为成本和处理时间,需进一步前瞻性验证临床影响。
核心结论
- 基于盆腔MRI的深部子宫内膜异位症三维建模在大规模应用上技术可行,尤其对复杂病例被认为有益,主要价值在于术前规划、手术教育和患者咨询。
主要发现
- 147例患者中41例MRI数据集允许三维重建,模型包含主要盆腔器官和DE结节。
- 两名专家外科医生在三分之二病例中评定附加价值为中等至显著(κ=0.41)。
- 全国调查31名受访者认为模型清晰精确(中位数4/5)。
- 与单独MRI相比,三维建模在48%病例改善病灶可视化,67%确认手术策略,8%修改策略;经验较少的外科医生感知获益更大。
- 2例前瞻性病例中三维模型改善术前沟通和患者理解,但术中应用仍有限。
关键数值与推荐
- 专家附加价值评定为中等至显著见于三分之二病例,一致性κ=0.41。
- 全国调查31名受访者对模型清晰精确度评分中位数4/5。
- 三维建模较单独MRI改善病灶可视化48%、确认手术策略67%、修改策略8%。
临床怎么用
- 三维建模可作为深部子宫内膜异位症术前规划、手术教学和患者咨询的辅助工具,尤其适用于复杂病例和经验较少的外科医生。
局限性
- 仅41/147例MRI数据集可完成三维重建,样本量有限。
- 主要推广障碍为成本和处理时间。
- 术中应用有限,需进一步前瞻性研究验证临床影响。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
OBJECTIVE: To evaluate the feasibility of 3-dimensional (3D) modeling of deep endometriosis (DE) from pelvic MRI, to assess its perceived usefulness by gynecologic surgeons, and to explore its transposability in clinical practice. DESIGN: Retrospective feasibility study with expert evaluation, national survey, and preliminary prospective cases. SETTING: University hospital and national network of gynecologic surgeons. PATIENTS: Consecutive women with surgically confirmed DE who underwent preoperative pelvic MRI with adequate image quality and an available radiology report between January 2010 and December 2022. INTERVENTIONS: Segmentation of pelvic MRI sequences and creation of individualized 3D models. MEASUREMENTS AND MAIN RESULTS: Among 147 patients, 41 MRI datasets allowed 3D reconstruction. The models included major pelvic organs and DE nodules. Two expert surgeons rated the added value as moderate to major in two-thirds of cases (κ = 0.41). In a national survey (n=31 respondents), the models were considered clear and precise (median 4/5). Compared with MRI alone, 3D modeling improved lesion visualization in 48% of cases, confirmed the surgical strategy in 67% and modified it in 8%. The perceived benefit was greater among less experienced surgeons. In 2 prospective cases, 3D models improved preoperative communication and patient understanding, although intraoperative use remained limited. Main barriers to wider use were cost and processing time. CONCLUSION: Large-scale 3D modeling of deep endometriosis from MRI is technically feasible and perceived as beneficial, especially in complex cases. Its main value lies in preoperative planning, surgical education, and patient counseling. Further prospective studies are required to validate its clinical impact.
引用
- Zhang C, Martel C, Host A, et al. Three-Dimensional Modeling of Deep Endometriosis From Pelvic MRI: Feasibility, Clinical Perception, and Preliminary Prospective Evaluation. J Minim Invasive Gynecol. 2026. PMID: 41722647. doi:10.1016/j.jmig.2026.02.029
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。