文献速递母胎医学产科

超声与MRI定性评估左侧先天性膈疝胎儿肺大小的可靠性研究

Qualitative Assessment of Foetal Lung Size in Left Congenital Diaphragmatic Hernia Using Ultrasound and MRI: A Retrospective Cohort Study.
PubMed 文献 · BJOG · 2025-12-22

本研究回顾性纳入2008-2020年单中心103例产前诊断孤立性左侧先天性膈疝且生后积极治疗的病例,其中74例同时有超声和MRI图像。两名独立评估者对胎儿肺大小进行定性评估,分析评估者间一致性及其与定量指标和新生儿死亡的相关性。结果显示超声定性评估一致性较强(加权kappa 0.80),MRI为中等(Cohen's kappa 0.48),两者与定量指标均强相关,且超声定性评估与新生儿死亡的相关性与定量评估相似。

要点

  • 超声定性评估胎儿肺大小的一致性较强,MRI为中等。
  • 超声和MRI定性评估与定量指标(o/e LHR和o/e TFLV)均强相关。
  • 超声定性评估与新生儿死亡的相关性与定量评估相似,支持其作为补充风险分层工具。

核心结论

  • 超声定性评估胎儿肺大小比MRI更可靠且可重复,与既定定量指标和新生儿死亡相关,支持其作为左侧先天性膈疝产前风险分层的补充方法。

研究设计与样本

  • 回顾性队列研究,单中心2008-2020年,103例产前诊断孤立性左侧先天性膈疝且生后积极治疗,其中74例同时有超声和MRI图像。

主要发现

  • 定性评估者间一致性超声为强(加权kappa 0.80,95% CI 0.68-0.93),MRI为中等(Cohen's kappa 0.48,95% CI 0.30-0.66)。
  • 超声和MRI定性评估与定量评估均强相关。
  • 超声上定性评估与定量评估和新生儿死亡的相关性相似(Spearman相关系数:每位评估者0.44 vs 0.49)。
  • MRI上定量指标与新生儿死亡的相关性强于定性评估(Cramér's V:0.44 vs 0.34-0.35)。

临床怎么用

  • 超声定性评估胎儿肺大小可作为左侧先天性膈疝产前风险分层的补充工具,尤其在与定量指标结合时。

局限性

  • 回顾性单中心研究,样本量有限(74例同时有超声和MRI),可能存在选择偏倚。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

OBJECTIVE: To evaluate the reliability of qualitative foetal lung size assessments on ultrasound (US) and MRI in left congenital diaphragmatic hernia (CDH) and their correlation with quantitative metrics and neonatal mortality. DESIGN: Retrospective cohort study. SETTING: Single tertiary center, 2008-2020. POPULATION: A total of 103 cases of prenatally diagnosed isolated left CDH underwent postnatal active care. METHODS: Two independent reviewers performed qualitative foetal lung size assessments on US and MRI. Interrater agreement was assessed, and correlations were determined between qualitative assessments, quantitative metrics (observed-to-expected lung-to-head ratio [o/e LHR] and observed-to-expected total Foetal lung volume [o/e TFLV]), and neonatal mortality. MAIN OUTCOME MEASURES: Interrater agreement and correlation between qualitative and quantitative assessments of lung size and neonatal mortality. RESULTS: A total of 74 cases with both US and MRI imaging were included. Interrater agreement for qualitative lung size assessment was strong for US (weighted kappa: 0.80, 95% CI 0.68-0.93) and moderate for MRI (Cohen's kappa: 0.48, 95% CI 0.30-0.66). Both modalities showed a strong correlation between qualitative and quantitative lung size assessments. On US, qualitative and quantitative assessments had similar associations with neonatal mortality (Spearman's correlation: 0.44 for each reviewer vs. 0.49). On MRI, quantitative metrics correlated more strongly with neonatal mortality than qualitative assessment (Cramér's V: 0.44 vs. 0.34-0.35). CONCLUSIONS: Qualitative foetal lung size assessment, by US more so than MRI, is a reliable and reproducible tool that correlates with established quantitative metrics and neonatal mortality. These findings support its role as a complementary method for prenatal risk stratification in left CDH.

来源:BJOG,查看原文。版权归原作者所有。

引用

  1. Shinar S, Kajal D, Johnson S, et al. Qualitative Assessment of Foetal Lung Size in Left Congenital Diaphragmatic Hernia Using Ultrasound and MRI: A Retrospective Cohort Study. BJOG. 2025. PMID: 41424179. doi:10.1111/1471-0528.70120

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。