文献速递产科母胎医学

双胎不良围产结局:双胎间胎儿大小不一致与单胎及双胎生长曲线的比较

Adverse perinatal outcomes in twins: comparison of intertwin fetal size discordance vs singleton and twin fetal growth charts.
PubMed 文献 · Ultrasound Obstet Gynecol · 2025-12-04

这项回顾性多中心队列研究纳入1294例双绒毛膜和487例单绒毛膜双胎妊娠,比较双胎间估计胎儿体重(EFW)不一致与基于单胎或双胎特异性FMF生长曲线的EFW百分位对复合不良围产结局(CAPO)的预测性能。结果显示,双胎间EFW不一致的预测AUC显著高于两种生长曲线百分位,在20%假阳性率下敏感性也更高。结论认为双胎间EFW不一致是更可靠的预测指标。

要点

  • 双胎间EFW不一致预测CAPO的AUC在双绒毛膜双胎为0.93,单绒毛膜双胎为0.95
  • 基于单胎或双胎特异性生长曲线的EFW百分位预测AUC均显著低于双胎间EFW不一致
  • 在20%假阳性率下,双胎间EFW不一致的敏感性达93%(双绒毛膜)和98%(单绒毛膜)

核心结论

  • 双胎间EFW不一致比基于单胎或双胎特异性生长曲线的EFW百分位更可靠地预测至少一胎死产和/或医源性早产<34周的复合结局。
  • 该方法规避了依赖不同胎儿生长参考曲线和任意截断值的局限性。
  • 经外部验证后,双胎间EFW不一致预测算法可能增强风险分层并改善双胎妊娠临床结局。

研究设计与样本

  • 回顾性多中心队列研究,纳入2013年1月至2023年12月英国、意大利和比利时三个三级胎儿医学中心管理的双胎妊娠。
  • 纳入标准为分娩前2周内或一胎/双胎宫内死亡诊断前2周内进行过产科超声胎儿生物测量。
  • 排除吻合口并发症病例;最终分析1294例双绒毛膜和487例单绒毛膜双胎妊娠。

主要发现

  • 双绒毛膜双胎中,双胎间EFW不一致预测CAPO的AUC为0.93(95%CI 0.89-0.98),单胎曲线EFW百分位AUC为0.83(95%CI 0.77-0.90,P=0.001),双胎特异性曲线AUC为0.87(95%CI 0.81-0.93,P=0.017)。
  • 单绒毛膜双胎中,双胎间EFW不一致预测CAPO的AUC为0.95(95%CI 0.92-0.97),单胎曲线EFW百分位AUC为0.80(95%CI 0.73-0.87,P<0.001),双胎特异性曲线AUC为0.83(95%CI 0.76-0.90,P<0.001)。
  • 在20%假阳性率下,双绒毛膜双胎预测CAPO的敏感性:单胎曲线74%、双胎特异性曲线81%、双胎间EFW不一致93%。
  • 在20%假阳性率下,单绒毛膜双胎预测CAPO的敏感性:单胎曲线75%、双胎特异性曲线79%、双胎间EFW不一致98%。

关键数值与推荐

  • 主要结局CAPO定义为至少一胎死产(宫内死亡≥22周)和/或胎儿指征的医源性早产(分娩<34周)。
  • 预测模型采用逻辑回归分析,通过受试者工作特征曲线下面积(AUC)评估,模型间成对比较使用DeLong检验。
  • 双胎间EFW不一致和较小胎儿的EFW百分位(基于单胎或双胎特异性FMF生长曲线)均被评估用于CAPO预测。

临床怎么用

  • 在双胎妊娠风险分层中,可优先关注双胎间EFW不一致而非仅依赖EFW百分位。
  • 双胎间EFW不一致预测算法经外部验证后可能辅助识别高风险双胎妊娠。
  • 临床解读EFW百分位时需注意其依赖的生长曲线类型和截断值可能影响预测性能。

局限性

  • 本研究为回顾性设计,可能存在选择偏倚。
  • 预测算法需外部验证后方可用于临床实践。
  • 排除吻合口并发症病例,结果可能不适用于该亚组。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

OBJECTIVE: To compare the predictive performance of intertwin estimated fetal weight (EFW) discordance and EFW centile calculated according to either the Fetal Medicine Foundation (FMF) singleton or twin-specific fetal growth charts for adverse perinatal outcome in dichorionic and monochorionic twin pregnancies. METHODS: This was a retrospective multicenter cohort study of twin pregnancies managed between January 2013 and December 2023 at three tertiary fetal medicine centers in the UK, Italy and Belgium. Twin pregnancies in which an obstetric ultrasound exam was performed to obtain fetal biometry within 2 weeks before live birth or diagnosis of intrauterine fetal demise of one or both twins were included. Cases with anastomotic complications were excluded. The primary outcome was a composite adverse perinatal outcome (CAPO), defined as stillbirth (intrauterine fetal demise ≥ 22 weeks) of at least one cotwin and/or iatrogenic early preterm birth (delivery < 34 weeks) for fetal indications. The predictive performance of intertwin EFW discordance and of the EFW centile of the smaller twin, calculated using either singleton or twin-specific FMF fetal growth charts, was assessed for CAPO. Predictive models were developed using logistic regression analysis and evaluated using the area under the receiver-operating-characteristics curve (AUC); pairwise comparisons between models were performed using DeLong's test. RESULTS: The study analyzed 1294 dichorionic and 487 monochorionic twin pregnancies. For the prediction of CAPO, intertwin EFW discordance in dichorionic twins achieved an AUC of 0.93 (95% CI, 0.89-0.98), compared with 0.83 (95% CI, 0.77-0.90) (P = 0.001) and 0.87 (95% CI, 0.81-0.93) (P = 0.017) for EFW centile based on singleton and twin-specific growth charts, respectively. Likewise, intertwin EFW discordance achieved an AUC of 0.95 (95% CI, 0.92-0.97) for predicting CAPO in monochorionic twins, outperforming EFW centile based on singleton charts (AUC, 0.80 (95% CI, 0.73-0.87); P < 0.001) and twin-specific growth charts (AUC, 0.83 (95% CI, 0.76-0.90); P < 0.001). In clinical terms, at a 20% false-positive rate (FPR), the sensitivity for CAPO in dichorionic twin pregnancies was 74%, 81% and 93% using singleton charts, twin-specific charts and intertwin EFW discordance, respectively. Similarly, in monochorionic twin pregnancies, the sensitivity at a FPR of 20% was 75%, 79% and 98% using singleton charts, twin-specific charts and intertwin EFW discordance, respectively. CONCLUSIONS: Intertwin EFW discordance is a more reliable predictor of the composite outcome of stillbirth in at least one cotwin and/or iatrogenic early preterm birth in twin pregnancies than is EFW centile based on either singleton or twin-specific growth charts. This approach addresses the limitations of using different fetal growth reference charts that rely on arbitrary cut-offs. Following external validation, the use of intertwin EFW discordance prediction algorithms may potentially enhance risk stratification to improve clinical outcomes in twin pregnancies. © 2025 The Author(s). Ultrasound in Obstetrics & Gynecology published by John Wiley & Sons Ltd on behalf of International Society of Ultrasound in Obstetrics and Gynecology.

来源:Ultrasound Obstet Gynecol,查看原文。版权归原作者所有。

引用

  1. Giorgione V, Lopian M, Trapani M, et al. Adverse perinatal outcomes in twins: comparison of intertwin fetal size discordance vs singleton and twin fetal growth charts. Ultrasound Obstet Gynecol. 2025. PMID: 41346036. doi:10.1002/uog.70139

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。