文献速递产科母胎医学

胎儿小颌畸形的产前超声诊断:定量方法的验证与可重复性

Antenatal ultrasound diagnosis of fetal micrognathia: validation and reproducibility of quantitative methods.
PubMed 文献 · Ultrasound Obstet Gynecol · 2025-11-20

该回顾性研究在2000至2018年间于伦敦大学学院医院纳入18至28周疑似小颌畸形胎儿,比较四种定量超声角度方法的诊断准确性与可重复性。结果显示FNMA可重复性最好、FMA最差,各方法诊断准确率差异大,测量误差可明显改变诊断。

要点

  • FNMA是可重复性最好的定量方法,FMA最差。
  • 各方法诊断小颌畸形的比例分别为IFA 14%、FNMA 100%、MNMA 88%、FMA 90%。
  • 加入观察者内误差后,满足诊断标准的比例分别降至IFA 0%、FNMA 87%、MNMA 49%、FMA 45%。

核心结论

  • 现有产前超声定量评估小颌畸形的方法诊断准确性不一且重复性不稳定,可能导致过度诊断或漏诊。
  • 测量FNMA是支持主观评估的首选方法,但需在前瞻性研究中进一步评估。

研究设计与样本

  • 回顾性研究,分析产前经主观方法诊断为疑似小颌畸形胎儿的侧面部图像。
  • 胎儿于2000至2018年间在英国伦敦大学学院医院招募,孕周18至28周。
  • 共132例疑似小颌畸形胎儿,其中84例有已知结局(终止妊娠56例、胎死宫内11例、新生儿死亡4例、活产13例),48例失访。
  • 可重复性评估使用49例胎儿面部侧面超声图像(终止妊娠22例、胎死宫内5例、新生儿死亡3例、活产6例、失访13例)。
  • 比较四种定量方法:下颌面部角(IFA)、额鼻颏角(FNMA)、上颌鼻下颌角(MNMA)和面部上颌角(FMA)。

主要发现

  • FNMA是可重复性最好的测量,FMA是可重复性最差的测量。
  • 采用原研究建议的切点,本队列中满足小颌畸形诊断标准的胎儿比例分别为IFA 14%、FNMA 100%、MNMA 88%、FMA 90%。
  • FNMA的观察者内和观察者间95% LoA分别为3.5%和9.5%,FMA分别为11.6%和45.0%。
  • 将观察者内最大随机误差加入原研究切点后,满足诊断标准的胎儿比例分别降至IFA 0%、FNMA 87%、MNMA 49%、FMA 45%。

局限性

  • 132例疑似小颌畸形胎儿中48例失访,可重复性分析仅纳入49例。
  • 原文结论指出需在前瞻性研究中进一步评估。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

OBJECTIVES: The antenatal ultrasound diagnosis of fetal micrognathia can be made subjectively or objectively. We aimed to validate quantitative ultrasound methods proposed for the diagnosis of fetal micrognathia in the second and third trimesters of pregnancy by evaluating their diagnostic performance, reproducibility and impact of measurement variability on diagnosis. METHODS: This was a retrospective study analyzing the objective diagnostic accuracy, reproducibility and impact of measurement variability of mandible angle measurements from facial profile images of fetuses with suspected micrognathia diagnosed antenatally using a subjective method. Fetuses were recruited at between 18 and 28 weeks' gestation, at University College London Hospital, UK, between 2000 and 2018. Four quantitative methods were compared: measurement of the inferior facial angle (IFA), the fronto-naso-mental angle (FNMA), the maxilla-nasion-mandible angle (MNMA) and the facial maxillary angle (FMA). Methods were validated by calculating the percentage of cases in which the measured angles met the diagnostic criteria for micrognathia. To assess intra- and interobserver reproducibility, two sonographers, blinded to each other's findings, measured each angle twice. Bland-Altman plots were used to calculate mean systematic differences and 95% limits of agreement (LoA). Data were expressed in degrees and as percentages to account for the increase in fetal size with advancing gestation. The impact of measurement variability was evaluated by recalculating the diagnostic accuracy adding to the angle cut-off the intraobserver 95% LoA. RESULTS: Of 132 fetuses diagnosed with suspected antenatal micrognathia, 84 cases had a known outcome (termination of pregnancy (n = 56); fetal demise (n = 11); neonatal death (n = 4); live birth (n = 13)) and 48 were lost to follow-up. Fetal facial profile ultrasound images were available for 49 cases in which reproducibility of the measurements was assessed (termination of pregnancy (n = 22); fetal demise (n = 5); neonatal death (n = 3); live birth (n = 6); lost to follow-up (n = 13)). FNMA was the most reproducible and FMA was the least reproducible measurement. Validation analysis showed that 14%, 100%, 88% and 90% of fetuses from our cohort met the criteria for the diagnosis of micrognathia using the cut-off criteria suggested in the original studies for IFA, FNMA, MNMA and FMA, respectively. The 95% LoA for intra- and interobserver reproducibility were 3.5% and 9.5% for FNMA, and 11.6% and 45.0% for FMA, respectively. When adding the intraobserver widest random error to the original study cut-offs, the percentage of fetuses meeting the criteria for diagnosis decreased to 0%, 87%, 49% and 45% for IFA, FNMA, MNMA and FMA, respectively. CONCLUSIONS: Current quantitative ultrasound methods to assess micrognathia antenatally have variable diagnostic accuracy and are not consistently reproducible, which can lead to overdiagnosis or missed diagnosis. Measurement of FNMA is the preferred method to support subjective assessment, however, further evaluation in prospective studies is warranted. © 2025 The Author(s). Ultrasound in Obstetrics & Gynecology published by John Wiley & Sons Ltd on behalf of International Society of Ultrasound in Obstetrics and Gynecology.

来源:Ultrasound Obstet Gynecol,查看原文。版权归原作者所有。

引用

  1. Denk MC, Bertin M, Donadono V, et al. Antenatal ultrasound diagnosis of fetal micrognathia: validation and reproducibility of quantitative methods. Ultrasound Obstet Gynecol. 2025. PMID: 41263617. doi:10.1002/uog.70137

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。