文献速递妇科

实时神经映射在累及坐骨神经与阴部神经的子宫内膜异位症手术中的应用

Real-time nerve mapping for endometriosis involving the sciatic and pudendal nerves.
PubMed 文献 · Fertil Steril · 2025-11-07

本文以视频形式展示一例36岁女性慢性右侧盆腔痛伴严重坐骨神经与阴部神经症状患者,在术中神经电生理监测(IONM)辅助下行腹腔镜深部浸润型子宫内膜异位症切除术,采用运动诱发电位监测坐骨、闭孔与阴部神经,经H反射间接监测S1神经根,并以定制3D打印Foley导尿管电极监测S2-S4骶神经根;切除顺利完成、无术中并发症,术后神经病理性疼痛明显改善、活动恢复,无新发运动或感觉缺损。

要点

  • 多模式IONM可在深部浸润型子宫内膜异位症切除术中实时验证坐骨、闭孔与阴部神经功能完整性。
  • H反射用于间接监测S1神经根,定制3D打印Foley导尿管电极用于监测S2-S4骶神经根。
  • 本例切除无术中并发症,术后右侧神经病理性疼痛明显改善、活动恢复,无新发运动或感觉缺损。

核心结论

  • 多模式IONM使累及坐骨神经与阴部神经的深部浸润型子宫内膜异位症得以安全有效地行保留神经的切除,凸显该创新方法在提升复杂手术安全性与精准性方面的价值。

研究设计与样本

  • 视频文章,展示一例36岁女性患者的标准化、可重复的IONM实时神经映射技术。

主要发现

  • 切除过程顺利完成,无术中并发症。
  • IONM验证坐骨、闭孔与阴部神经在整个手术过程中持续保持功能完整性。
  • 术后患者右侧神经病理性疼痛明显改善、活动恢复,未观察到新发运动或感觉缺损。

关键数值与推荐

  • 采用运动诱发电位持续评估坐骨、闭孔与阴部神经的功能完整性。
  • 通过H反射间接监测S1神经根,实时反馈坐骨神经功能。
  • 使用定制3D打印Foley导尿管(内置电极)监测阴部神经活动,以评估参与控尿的S2-S4骶神经根。

临床怎么用

  • 原文未据此给出推荐。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

OBJECTIVE: To demonstrate a standardized and reproducible technique utilizing intraoperative neurophysiological monitoring (IONM) with real-time nerve mapping to improve the safety of deep infiltrating endometriosis surgery and facilitate the preservation of deep pelvic nerves. DESIGN: Video article. SUBJECTS: A 36-year-old woman presented with chronic right-sided pelvic pain, including severe sciatic and pudendal nerve symptoms. The patient included in this video gave consent for publication of the video and posting of the video online, including social media, the journal website, scientific literature websites (such as PubMed, ScienceDirect, and Scopus, etc.) and other applicable sites. EXPOSURE: Laparoscopic excision of deeply infiltrative endometriosis performed with the assistance of IONM to preserve motor nerve functions. Motor-evoked potentials were used to continuously assess the functional integrity of the sciatic, obturator, and pudendal nerves. Additionally, the S1 nerve root was indirectly monitored via the H-reflex, providing real-time feedback on sciatic nerve function. To evaluate the sacral roots involved in continence (S2-S4), a custom 3D-printed Foley catheter with embedded electrodes was used to monitor pudendal nerve activity. MAIN OUTCOME MEASURES: The endometriosis excision was completed without complications, with IONM verifying the functional integrity of all major pelvic nerves. RESULTS: The excision procedure was successfully completed without intraoperative complications. Intraoperative neurophysiological monitoring verified continuous functional integrity of the sciatic, obturator, and pudendal nerves throughout the procedure. Postoperatively, the patient reported significant improvement in right-sided neuropathic pain and restored mobility. No new motor or sensory deficits were observed. CONCLUSION: Multimodal IONM enabled safe and effective nerve-sparing excision of deeply infiltrative endometriosis involving the sciatic and pudendal nerves, highlighting the value of this innovative approach in advancing the safety and precision of complex surgery.

来源:Fertil Steril,查看原文。版权归原作者所有。

引用

  1. Seckin TK, Chu A, Kula H, et al. Real-time nerve mapping for endometriosis involving the sciatic and pudendal nerves. Fertil Steril. 2025. PMID: 41205980. doi:10.1016/j.fertnstert.2025.10.031

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。