文献速递生殖医学

最小化母源污染影响的非侵入性染色体筛查算法

Algorithms to minimize the effect of maternal contamination in non-invasive chromosome screening.
PubMed 文献 · Reprod Biomed Online · 2025-04-10

研究开发了基于X和Y染色体嵌合比例确认母源污染比例的算法,以及校正拷贝数变异(CNV)的算法;在317份培养液样本中检出88份(27.8%)母源污染,校正后男性胚胎CNV结果与全胚胎结果一致性从10.9%升至69.1%(P<0.001);临床研究中活产率44.7%,算法在25枚捐赠胚胎和47例产前检测中总体一致率95.8%(69/72)。

要点

  • 基于X、Y染色体嵌合比例可确认培养液中母源污染比例。
  • CNV校正算法提高男性胚胎CNV结果与全胚胎结果一致性至69.1%。
  • 校正后部分初始整倍体或嵌合体样本被重新分类。

核心结论

  • CNV校正算法可用于最小化培养液中母源污染的影响并提高非侵入性染色体筛查的准确性。

研究设计与样本

  • 开发基于X和Y染色体嵌合比例确认母源污染比例的算法及校正CNV的算法,并在317份培养液样本中测试算法性能,随后开展前瞻性临床研究验证准确性。

主要发现

  • 55枚母源污染的男性胚胎中,校正后CNV结果与全胚胎结果一致性为69.1%,校正前为10.9%(P<0.001)。
  • 317份胚胎培养液样本中,通过基于X和Y染色体嵌合比例的算法及定量亲源污染检测识别出88份(27.8%)母源污染。
  • 初始判定为整倍体的19份样本中,经CNV校正算法重新评估后2份重新分类为嵌合体、5份重新分类为非整倍体。
  • 初始判定为嵌合体的36份样本中,23份重新分类为非整倍体、3份重新分类为整倍体。
  • 临床研究中活产率为44.7%;在25枚捐赠胚胎和47例产前检测中评估算法准确性,总体一致率为95.8%(69/72)。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

RESEARCH QUESTION: Can algorithms be developed to assess maternal contamination in the embryo spent culture medium without parental samples and correct copy number variations (CNV)? DESIGN: An algorithm was developed to confirm the proportion of maternal contamination based on the mosaic ratios of X and Y chromosomes and an algorithm to correct copy number variation (CNV) in embryos with maternal contamination. Performance of algorithms was tested in 317 culture medium samples. A prospective clinical study was then conducted to validate the accuracy. RESULTS: Among 55 male embryos with maternal contamination, the consistency of the corrected CNV results with the whole embryo results was higher than that of the CNV results before correction (69.1% versus 10.9%, P < 0.001). Among the 317 embryo culture medium samples, maternal contamination was identified in 88 (27.8%) samples through the algorithm based on the mosaic ratios of X and Y chromosomes and quantitative parental contamination test. Upon re-assessment using the CNV correction algorithm, two and five of the 19 samples deemed as euploid initially were re-classified as mosaic and aneuploid, respectively; 23 and three of the 36 samples deemed as mosaic initially were re-classified as aneuploid and euploid, respectively. In the clinical study, the live birth rate was 44.7%. Accuracy of the algorithms was assessed in 25 donated embryos and 47 cases with prenatal testing. The overall concordance rate was 95.8% (69/72). CONCLUSIONS: The CNV correction algorithm could be used to minimize the effect of maternal contamination in culture medium and enhance the accuracy of non-invasive chromosome screening.

来源:Reprod Biomed Online,查看原文。版权归原作者所有。

引用

  1. Chang X, Yao Y, Zou Y, et al. Algorithms to minimize the effect of maternal contamination in non-invasive chromosome screening. Reprod Biomed Online. 2025. PMID: 40829487. doi:10.1016/j.rbmo.2025.104994

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。