指南与共识妇科

超声诊断子宫腺肌症的准确性——2022年MUSA指南的盲法、回顾性、单一专家验证研究

Diagnostic Accuracy of Ultrasound for Adenomyosis-A Blinded, Retrospective, Single-Expert Validation Study of the 2022 MUSA Guidelines.
指南 / 共识 · J Minim Invasive Gynecol · 2025-08-07

本回顾性队列研究在大型学术医疗中心纳入26例子宫切除术患者,由对病理结果设盲的妇科超声专科妇产科医生依据2022年MUSA指南评估超声图像。复合直接标志物敏感度为100%(95%CI:100.0-100.0),特异度为35.7%(95%CI:10.6-60.8)。AUC最高的标志物为子宫内膜下高回声线与芽,AUC为73.1(95%CI:56.0-90.1)。

要点

  • 复合直接标志物诊断子宫腺肌症的敏感度为100%(95%CI:100.0-100.0),特异度为35.7%(95%CI:10.6-60.8)。
  • 子宫内膜下高回声线与芽的AUC最高,为73.1(95%CI:56.0-90.1),敏感度83.3%(95%CI:62.2-100.0),特异度64.3%(95%CI:39.2-89.4)。
  • 子宫肌层囊肿敏感度最低(25%,95%CI:0.5-49.5)但特异度最高(85.7%,95%CI:67.4-100.0),AUC为57.7(95%CI:38.7-76.7)。

核心结论

  • 在这项对近期发表的子宫腺肌症超声表现指南的盲法验证研究中,复合直接表现及所有表现的敏感度高。
  • AUC最高的表现为子宫内膜下高回声线与芽。
  • 尽管这是一项小型研究,但它是超声标志物预测子宫腺肌症价值的有前景的探索。

研究设计与样本

  • 回顾性队列研究,在大型学术医疗中心进行。
  • 纳入2022年接受子宫切除术且术前一年内曾在专科妇科超声中心行超声检查的患者。
  • 干预为子宫切除术和术前经阴道超声。
  • 图像由对病理结果设盲的妇科超声专科妇产科医生复核。
  • 样本包括26例子宫切除术,子宫腺肌症的组织学患病率为46.2%。

主要发现

  • 复合直接标志物敏感度为100%(95%CI:100.0-100.0),特异度为35.7%(95%CI:10.6-60.8),AUC为65.4(95%CI:47.1-83.7)。
  • 子宫内膜下高回声线与芽敏感度为83.3%(95%CI:62.2-100.0),特异度为64.3%(95%CI:39.2-89.4),AUC为73.1(95%CI:56.0-90.1)。
  • 子宫肌层囊肿敏感度为25%(95%CI:0.5-49.5),特异度为85.7%(95%CI:67.4-100.0),AUC为57.7(95%CI:38.7-76.7)。

关键数值与推荐

  • 复合直接标志物:敏感度100%(95%CI:100.0-100.0),特异度35.7%(95%CI:10.6-60.8),AUC 65.4(95%CI:47.1-83.7)。
  • 子宫内膜下高回声线与芽:敏感度83.3%(95%CI:62.2-100.0),特异度64.3%(95%CI:39.2-89.4),AUC 73.1(95%CI:56.0-90.1)。
  • 子宫肌层囊肿:敏感度25%(95%CI:0.5-49.5),特异度85.7%(95%CI:67.4-100.0),AUC 57.7(95%CI:38.7-76.7)。

临床怎么用

  • 原文未据此给出推荐。

局限性

  • 尽管这是一项小型研究,但它是超声标志物预测子宫腺肌症价值的有前景的探索。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

STUDY OBJECTIVE: To examine the predictive value of the 2022 Morphological Uterus Sonographic Assessment ultrasound markers for the diagnosis of adenomyosis. DESIGN: Retrospective cohort study. SETTING: Large academic medical center. PATIENTS: Patients who underwent a hysterectomy procedure in 2022 and had an ultrasound within the prior year at a specialized gynecologic ultrasound center. INTERVENTIONS: Hysterectomy and preoperative transvaginal ultrasound. MEASUREMENTS AND MAIN RESULTS: The images were reviewed by an obstetrician-gynecologist specialized in gynecologic ultrasound who was blinded to the pathology results. Presence or absence of each Morphological Uterus Sonographic Assessment marker was documented and compared to the pathology results. The sensitivity, specificity, and area under the curve (AUC) were calculated for each individual finding and for composite measures. Our sample included 26 hysterectomies. The histologic prevalence of adenomyosis was 46.2%. The composite direct markers had a sensitivity of 100% (95% CI: 100.0-100.0) and a specificity of 35.7% (95% CI: 10.6-60.8) with an AUC of 65.4 (95% CI: 47.1-83.7). The marker with the highest AUC was echogenic subendometrial lines and buds with a sensitivity of 83.3 (95% CI: 62.2-100.0), and a specificity of 64.3 (95% CI: 39.2-89.4), and AUC of 73.1 (95% CI: 56.0-90.1). The direct finding with the lowest sensitivity but highest specificity was myometrial cysts with a sensitivity of 25% (95% CI: 0.5-49.5) and a specificity of 85.7 (95% CI: 67.4-100.0) and AUC of 57.7 (95% CI: 38.7-76.7). CONCLUSION: In this blinded validation study of recently published guidelines on the ultrasound findings indicative of adenomyosis, we found a high sensitivity for the composite direct findings and all findings. The finding with the highest AUC was subendometrial lines and buds. Although this is a small study, it is a promising look at the value of ultrasound markers in predicting adenomyosis.

来源:J Minim Invasive Gynecol,查看原文。版权归原作者所有。

引用

  1. Maghsoudlou P, Chatroux LR, Ajao MO, et al. Diagnostic Accuracy of Ultrasound for Adenomyosis-A Blinded, Retrospective, Single-Expert Validation Study of the 2022 MUSA Guidelines. J Minim Invasive Gynecol. 2025. PMID: 40783173. doi:10.1016/j.jmig.2025.07.024

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。