文献速递母胎医学产科

亚洲人群产前队列中胎儿偏侧缺陷的超声与遗传特征

The Ultrasound and Genetic Characteristics of Fetuses With Laterality Defects-A Prenatal Cohort in Asian Population.
PubMed 文献 · Prenat Diagn · 2025-07-16

本研究对胎儿偏侧缺陷(包括完全性内脏反位和内脏异位)进行胎儿超声心动图及心外结构评估,并开展染色体微阵列分析和三联外显子组测序。结果发现内脏异位胎儿心脏畸形发生率显著高于完全性内脏反位组(30/31 vs. 2/36,p < 0.001)。遗传学检测发现心脏发育候选基因的变异,除CFAP300 c.604delG和KMT2D c.16351T>C被评为「可能致病」外,其余均为意义未明变异。

要点

  • 内脏异位胎儿心脏畸形发生率显著高于完全性内脏反位胎儿(30/31 vs. 2/36,p < 0.001)。
  • 右异构中单心房单心室发生率显著高于左异构(12/19 vs. 3/12,p = 0.029)。
  • 左异构中右室双出口发生率显著高于右异构(5/12 vs. 1/19,p = 0.022)。

核心结论

  • 与完全性内脏反位胎儿相比,内脏异位胎儿合并心脏畸形的可能性显著更高。
  • 遗传学检测发现了可能在正常胎儿内脏定位机制中起关键作用的潜在遗传变异。
  • 需要进一步研究以探索这些遗传变异的临床意义,并提高对胎儿偏侧缺陷病因和管理的理解。

研究设计与样本

  • 研究为产前队列,纳入亚洲人群胎儿,对胎儿进行详细的超声心动图及心外结构评估。
  • 遗传学检测包括染色体微阵列分析和三联外显子组测序,以识别潜在遗传变异。

主要发现

  • 内脏异位组心脏畸形发生率为30/31,完全性内脏反位组为2/36,内脏异位组显著高于完全性内脏反位组(p < 0.001)。
  • 右异构中单心房单心室发生率为12/19,左异构中为3/12,右异构显著高于左异构(p = 0.029)。
  • 左异构中右室双出口发生率为5/12,右异构中为1/19,左异构显著高于右异构(p = 0.022)。
  • 遗传学检测发现心脏发育候选基因的变异,除CFAP300 c.604delG和KMT2D c.16351T>C被评为「可能致病」外,其余变异均归类为意义未明变异,部分胎儿存在复合杂合变异。

局限性

  • 需要进一步研究以探索这些遗传变异的临床意义,并提高对胎儿偏侧缺陷病因和管理的理解。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

OBJECTIVE: To investigate the distribution of laterality defects in fetuses, including situs inversus totalis (SIT) and situs ambiguous (SA), and to explore the potential genetic etiology of these laterality defects. METHODS: Detailed fetal echocardiography and extracardiac structural evaluations were performed. Genetic testing, including chromosomal microarray analysis, and trio exome sequencing was conducted to identify potential genetic variants. RESULTS: The incidence of heart malformation was significantly higher in SA fetuses than in SIT group (30/31 vs. 2/36, p < 0.001). The incidence of univentricular heart with single atrium was significantly higher in right isomerism compared with left isomerism (12/19 vs. 3/12, p = 0.029), while the incidence of double outlet right ventricle was significantly higher in left isomerism (5/12 vs. 1/19, p = 0.022). Genetic testing identified variation within candidate genes of cardiac development. Except for CFAP300 c.604delG and KMT2D c.16351T>C, which were rated as "likely pathogenic", all other variants were categorized as variants of uncertain significance, with some fetuses having compound heterozygous variations. CONCLUSION: Fetuses with SA have a significantly higher likelihood of concurrent heart malformations compared with those with SIT. Genetic testing identified potential genetic variants that may play crucial roles in the mechanisms underlying normal fetal visceral positioning. Further studies are needed to explore the clinical significance of these genetic variants and to improve our understanding of the etiology and management of fetal laterality defects.

来源:Prenat Diagn,查看原文。版权归原作者所有。

引用

  1. Yi W, Renyi H, Yiyao C, et al. The Ultrasound and Genetic Characteristics of Fetuses With Laterality Defects-A Prenatal Cohort in Asian Population. Prenat Diagn. 2025. PMID: 40670315. doi:10.1002/pd.6857

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。