完全性纵隔子宫并双宫颈患者的腹腔镜经腹宫颈环扎术
这是一例33岁、孕2产0(G2P0201)、有宫颈环形电切术和阴道纵隔切除术史的完全性纵隔子宫并双宫颈患者,曾被误诊为双子宫并双宫颈。她此前经阴道宫颈环扎失败,遂接受无针腹腔镜经腹宫颈环扎术,术前磁共振成像明确了子宫畸形。作者认为,经腹宫颈环扎对先天子宫畸形患者是可行的替代方案。
要点
- 经腹宫颈环扎适用于经阴道环扎失败或阴道途径技术上困难者,如苗勒管畸形、宫颈手术史或双宫颈。
- 苗勒管畸形患者行环扎前,需通过先进影像准确识别解剖结构,以制定手术方案并向患者说明环扎方式。
- 本例采用无针腹腔镜经腹宫颈环扎,在宫颈内口水平仔细分离子宫血管后,于血管内侧建立隧道,使用不可吸收编织聚酯缝线。
核心结论
- 经腹宫颈环扎对先天子宫畸形患者是可行的替代方案,因为经阴道途径可能增加失败风险。
- 通过先进影像准确诊断、多学科会诊和个体化手术规划,是优化生殖结局的关键。
研究设计与样本
- 病例报告:33岁、孕2产0(G2P0201)女性,有宫颈环形电切术和阴道纵隔切除术史,曾被误诊为双子宫并双宫颈。
- 她第二次妊娠时,针对与妊娠宫腔相连的宫颈放置的病史指征经阴道宫颈环扎失败,遂转诊至作者所在机构接受经腹宫颈环扎。
- 术前进行了磁共振成像检查;患者同意视频发表及在网上包括社交媒体、期刊网站、科学文献网站(如PubMed、ScienceDirect、Scopus等)和其他适用网站发布。
主要发现
- 磁共振成像显示完全性纵隔子宫并双宫颈。
- 在宫颈内口水平仔细分离子宫血管并在其内侧建立隧道后,放置了无针腹腔镜经腹宫颈环扎,使用不可吸收编织聚酯缝线。
临床怎么用
- 作者认为,经腹宫颈环扎对先天子宫畸形患者是可行的替代方案,因为经阴道途径可能增加失败风险。
- 作者认为,通过先进影像准确诊断、多学科会诊和个体化手术规划是优化生殖结局的关键。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
UNLABELLED: Cervical insufficiency is a significant cause of second-trimester loss and preterm birth. Transabdominal cerclage is indicated after failed transvaginal cerclage or anatomical factors that make a vaginal approach technically difficult-such as müllerian anomalies, prior cervical surgery, or cervical duplication. In patients with müllerian anomalies undergoing a cerclage placement, it is critical to properly identify the anatomy for surgical planning and patient counseling of the cerclage method. OBJECTIVE: To describe transabdominal cerclage indications and surgical technique and to illustrate a needleless laparoscopic abdominal cerclage placement in a patient with a complete septate uterus and duplicated cervices and important related considerations. DESIGN: Case report. SUBJECTS: This case describes a 33-year-old G2P0201 female, with a history of undergoing a loop electrosurgical excision procedure and longitudinal vaginal septum resection, and who was previously misdiagnosed with a didelphic uterus and duplicated cervices. She had a failed history-indicated transvaginal cerclage placed around the cervix connected to the gravid hemicavity during her second pregnancy and was referred to our practice for transabdominal cerclage placement. A preoperative magnetic resonance imaging scan was performed. (The patient(s) included in this video gave consent for publication of the video and posting of the video online including social media, journal website, scientific literature websites [such as PubMed, ScienceDirect, Scopus, etc.] and other applicable sites.) INTERVENTION: Needleless laparoscopic transabdominal cerclage. MAIN OUTCOME MEASURES: Preoperative workup, imaging, and surgical technique. RESULTS: Magnetic resonance imaging scan revealed a complete septate uterus with duplicated cervices. A needleless laparoscopic transabdominal cerclage was placed after careful dissection of the uterine vessels at the level of the internal cervical os and creation of a tunnel medial to them. Nonabsorbable, braided polyester suture was used. CONCLUSION: Transabdominal cerclage is a feasible alternative in patients with congenital uterine anomalies, as a transvaginal approach might increase the risk of failure. Accurate diagnosis through advanced imaging, multidisciplinary consultation, and individualized surgical planning are key to optimizing reproductive outcomes.
引用
- Alzamora Schmatz MC, Sridhar S, Billow M, et al. Laparoscopic transabdominal cerclage in a patient with a complete septate uterus and duplicated cervices. Fertil Steril. 2025. PMID: 40618985. doi:10.1016/j.fertnstert.2025.06.044
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。