双绒毛膜双羊膜囊双胎妊娠羊膜腔穿刺术与胎儿丢失风险:病例对照研究
该回顾性观察性病例对照研究纳入2010年1月至2023年12月期间接受羊膜腔穿刺的双绒毛膜双羊膜囊(DCDA)双胎妊娠220例为病例组,未穿刺的662例为对照组,发现穿刺相关胎儿丢失率两组无差异(单胎丢失0.9% vs 1.1%,双胎丢失0.5% vs 0.5%,p=0.982),结论认为羊膜腔穿刺似乎不增加无并发症DCDA双胎妊娠的胎儿丢失风险。
要点
- DCDA双胎妊娠羊膜腔穿刺相关胎儿丢失率与对照组无显著差异。
- 单胎丢失率病例组0.9% vs 对照组1.1%,双胎丢失率两组均为0.5%(p=0.982)。
- 多因素分析证实羊膜腔穿刺对胎儿丢失风险无显著影响。
核心结论
- 羊膜腔穿刺似乎不增加无并发症DCDA双胎妊娠的胎儿丢失风险,使其高于双胎妊娠的基线丢失风险。
研究设计与样本
- 回顾性观察性病例对照研究,病例组为2010年1月至2023年12月期间接受羊膜腔穿刺的DCDA双胎妊娠220例,对照组为同期未接受羊膜腔穿刺的DCDA双胎妊娠662例。
主要发现
- 主要结局穿刺相关单胎丢失率病例组0.9% vs 对照组1.1%,双胎丢失率两组均为0.5%(p=0.982)。
- 次要结局单胎丢失率病例组1.8% vs 对照组2.1%,双胎丢失率病例组0.5% vs 对照组0.8%(p=0.853)。
- 多因素分析证实羊膜腔穿刺对胎儿丢失风险无显著影响。
关键数值与推荐
- 穿刺相关单胎丢失率病例组0.9% vs 对照组1.1%(p=0.982)。
- 穿刺相关双胎丢失率病例组0.5% vs 对照组0.5%(p=0.982)。
- 单胎丢失率病例组1.8% vs 对照组2.1%(p=0.853)。
- 双胎丢失率病例组0.5% vs 对照组0.8%(p=0.853)。
临床怎么用
- 原文未据此给出推荐。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
OBJECTIVE: There is a paucity of data regarding the risk of fetal loss due to invasive prenatal diagnosis in twins. The aim of the present study is to assess the rate of amniocentesis-related fetal loss in uncomplicated dichorionic-diamniotic (DCDA) twin pregnancies. METHODS: Retrospective observational case-control study. DCDA twin pregnancies undergoing amniocentesis between January 2010 and December 2023 formed the case group. The control group comprised counterparts who did not undergo amniocentesis. The primary outcome of the study was procedure-related fetal loss. Secondary outcomes were miscarriage rate, overall fetal loss and gestational age at birth. RESULTS: Our dataset included 220 and 662 women in the case and control groups, respectively. No difference in the primary outcome was found: procedure-related fetal loss of one fetus was 0.9% in the case group and 1.1% in the control group, and of both fetuses it was 0.5% in both groups (p = 0.982). No difference was found in secondary outcomes: the fetal loss rate of one fetus was 1.8% in the case group and 2.1% in the control group, while that of both fetuses it was 0.5% and 0.8% respectively (p = 0.853). Multivariate analysis confirmed the nonsignificant effect of amniocentesis on the risk of fetal loss. CONCLUSION: Amniocentesis does not seem to increase the risk of fetal loss in uncomplicated DCDA twin pregnancies above the baseline risk of loss among twin gestations.
引用
- Roero S, Ingala A, Arduino S, et al. Amniocentesis and Risk of Fetal Loss in Dichorionic-Diamniotic Twin Pregnancy: A Case-Control Study. Prenat Diagn. 2025. PMID: 40102011. doi:10.1002/pd.6777
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。