经阴道宫颈环扎术:双单丝改良Wurm法与单编织McDonald法的比较

Transvaginal cervical cerclage: double monofilament modified Wurm vs single braided McDonald technique.
PubMed 文献 · Ultrasound Obstet Gynecol · 2025-02-25

单中心前瞻性观察研究比较高危早产孕妇经阴道宫颈环扎的改良Wurm法(双单丝缝线)与McDonald法(单编织缝线)的妊娠结局。在宫颈长度≤25 mm者中,改良Wurm法<32周早产率显著低于McDonald法(3(9%)vs 14(29%);aOR 0.25,95%CI 0.06-0.95;P=0.042),但研究把握度不足。总体人群<32周早产率两组无显著差异(7(13%)vs 22(24%);aOR 0.51,95%CI 0.20-1.33;P=0.169)。

要点

  • 宫颈长度≤25 mm者中,改良Wurm法<32周早产率显著低于McDonald法(3(9%)vs 14(29%);aOR 0.25,P=0.042)。
  • 总体人群<32周早产率两组无显著差异(7(13%)vs 22(24%);aOR 0.51,P=0.169)。
  • 妊娠丢失率与新生儿复合发病率/死亡率两组无显著差异。

核心结论

  • 在超声提示宫颈短的高危孕妇中,改良Wurm宫颈环扎与McDonald宫颈环扎相比,<32周早产率更低。
  • 需要在更大队列中进一步研究以确认该发现,并确定该技术能否降低无宫颈缩短的选择性宫颈环扎后的早产率。

研究设计与样本

  • 单中心前瞻性观察研究,纳入因早产风险增高就诊于早产监测门诊并接受病史指征或超声指征经阴道宫颈环扎的单胎妊娠孕妇。
  • 最终分析147例:55例(37%)接受改良Wurm环扎,92例(63%)接受McDonald环扎;环扎方式由医生酌情选择。
  • 改良Wurm技术使用单丝材料,放置两道环周缝线,每道两个进针点(共四个进针点);McDonald技术使用单编织缝线,采用菱形进针法,共四个进针点。
  • 主要结局为<32周早产率,并按环扎指征(病史指征或超声指征)、任何孕周早产率(<37、<34、<28和<24周)及超声宫颈长度≤25 mm和≤15 mm进行预设亚组分析。
  • 次要结局包括母儿不良事件与结局及手术前后特征;另用Bland-Altman图评估环扎前后超声评估宫颈长度的观察者内和观察者间可重复性。

主要发现

  • 改良Wurm组22例(40%)为病史指征环扎,McDonald组50例(54%)为病史指征环扎,其余为超声指征环扎。
  • 在宫颈长度≤25 mm者中,<32周早产率改良Wurm组3例(9%)vs McDonald组14例(29%);aOR 0.25(95%CI 0.06-0.95);P=0.042。
  • 总体人群中<32周早产率改良Wurm组7例(13%)vs McDonald组22例(24%);aOR 0.51(95%CI 0.20-1.33);P=0.169,无显著差异。
  • 妊娠丢失率改良Wurm组2例(4%)vs McDonald组7例(8%);OR 0.47(95%CI 0.09-2.33);P=0.485。
  • 新生儿复合发病率/死亡率改良Wurm组5例(9%)vs McDonald组11例(13%);OR 0.68(95%CI 0.22-2.09);P=0.593。

局限性

  • 研究把握度不足,无法提供确定性结论。
  • 需要在更大队列中进一步研究以确认该发现。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

OBJECTIVE: To compare pregnancy outcome in women at high risk of preterm birth undergoing the modified Wurm (two monofilament sutures) vs those undergoing the McDonald (single braided suture) transvaginal cervical cerclage technique. METHODS: This was a single-center prospective observational study of all women with a singleton pregnancy attending a prematurity surveillance clinic because of an increased risk of preterm birth, and undergoing history- or ultrasound-indicated transvaginal cervical cerclage. Two cerclage techniques were evaluated and the choice of cerclage was at the physician's discretion. In the modified Wurm technique using monofilament material, two circumferential sutures are placed with two insertions each (four in total). Outcomes were compared vs those of women undergoing the McDonald technique (single braided suture using a diamond-type insertion method with four insertions in total). Primary outcome was the rate of preterm birth at < 32 weeks' gestation, with planned subanalyses according to cervical cerclage indication (history- or ultrasound-indicated), preterm birth rate at any gestational age (< 37, < 34, < 28 and < 24 weeks), and sonographic cervical length (CL) of ≤ 25 mm and ≤ 15 mm. Secondary outcome measures included maternal and neonatal adverse events and outcomes, including the pre- and postsurgical characteristics. In addition, a reproducibility analysis using Bland-Altman plots was performed to evaluate the intra- and interobserver reproducibility in assessment of CL on ultrasound examination before and after cerclage. RESULTS: In total, 147 patients were included in the final analysis: 55 (37%) received modified Wurm cerclage and 92 (63%) received McDonald cerclage. Other than race, demographic characteristics were comparable between the two groups. Of these, 22 (40%) women in the modified Wurm group had history-indicated cerclage, vs 50 (54%) women in the McDonald group; the remaining cerclages were ultrasound-indicated. In women with a short CL (≤ 25 mm), there was a significantly lower rate of preterm birth at < 32 weeks' gestation after modified Wurm compared with the McDonald technique (3 (9%) vs 14 (29%); adjusted odds ratio (aOR), 0.25 (95% CI, 0.06-0.95); P = 0.042). However, the study was underpowered to provide definitive conclusions. In the overall population, there was no significant difference in preterm birth rate for < 32 weeks' gestation between the two techniques (7 (13%) vs 22 (24%); aOR, 0.51 (95% CI, 0.20-1.33); P = 0.169). There was no difference in overall surgical complications between the two techniques. The pregnancy loss rate and composite neonatal morbidity/mortality rate were comparable between the two groups (2 (4%) vs 7 (8%); odds ratio (OR), 0.47 (95% CI, 0.09-2.33); P = 0.485; and 5 (9%) vs 11 (13%); OR, 0.68; (95% CI, 0.22-2.09); P = 0.593, respectively). CONCLUSIONS: In high-risk women with a sonographic short CL, placement of a modified Wurm cervical cerclage is associated with a lower rate of preterm birth < 32 weeks compared with McDonald cervical cerclage. Further research in larger cohorts is needed to confirm this finding and to determine if this technique reduces the preterm birth rate after elective cervical cerclage without CL shortening. © 2025 The Author(s). Ultrasound in Obstetrics & Gynecology published by John Wiley & Sons Ltd on behalf of International Society of Ultrasound in Obstetrics and Gynecology.