颈项透明层在检测全基因组无创产前检测遗漏的染色体异常中有多大价值及应采用何种测量阈值
该4年回顾性研究纳入919例接受一线全基因组无创产前检测(gwNIPT)后行侵入性产前诊断的单胎妊娠,评估颈项透明层(NT)测量对gwNIPT未识别遗传异常的检测效用及最佳NT阈值。结果显示,NT增大对gwNIPT未识别的遗传异常预测价值差;采用固定NT阈值3.5 mm时,假阳性率低,检出率与更低阈值相似,阳性预测值更高。
要点
- gwNIPT存在筛查局限性,无法检测微缺失/微重复及三倍体。
- NT增大对gwNIPT未识别的遗传异常预测价值差。
- 固定NT阈值3.5 mm假阳性率低,检出率与更低阈值相似,阳性预测值更高。
核心结论
- NT增大对gwNIPT未识别的遗传异常预测价值差。
- 采用固定NT阈值3.5 mm时,假阳性率低,检出率与更低阈值相似,阳性预测值更高。
研究设计与样本
- 4年回顾性研究,纳入接受一线gwNIPT非整倍体筛查后行绒毛膜绒毛取样或羊膜腔穿刺侵入性产前诊断的单胎妊娠。
- 静态和基于中位数倍数(MoM)的NT切点的人群比例来自所有11–14周超声检查。
主要发现
- 919例接受gwNIPT和侵入性检测的妊娠中,338例有单一遗传异常。
- 该队列中有9例gwNIPT假阴性结果和26例无法检测的异常(18例微缺失/微重复,8例三倍体)。
- 12例有双重染色体异常,其中4例gwNIPT结果为低风险。
- 33例「遗漏病例」也接受了13周扫描,应用了各种NT阈值(3.0 mm、1.6 MoM、3.5 mm和1.9 MoM)。
- 仅3例(9%)NT超过3.0 mm,所有更高切点的检出率相似;静态和基于MoM的NT切点阳性预测值相似。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
INTRODUCTION: Genome-wide non-invasive prenatal testing (gwNIPT) has screening limitations for detectable genetic conditions and cannot detect microdeletions/microduplications (MD) or triploidy. Nuchal translucency (NT) increases with gestation and with genetic or structural abnormalities. This study aims to determine the utility of NT measurement in detecting genetic abnormalities not identified by gwNIPT and the optimal NT threshold value. METHODS: A 4-year retrospective study of singleton pregnancies undergoing first-line gwNIPT aneuploidy screening where invasive prenatal testing by CVS/or amniocentesis was subsequently undertaken. Population proportions for static and multiple of the median (MoM) NT cut-offs were derived from all 11-14 weeks ultrasound examinations. RESULTS: Among 919 pregnancies with gwNIPT and invasive testing, 338 had a single genetic abnormality. There were 9 false negative GwNIPT results and a further 26 undetectable abnormalities (18 MD, 8 triploidy) in this cohort. Twelve had a dual chromosomal abnormality, four of which returned a low-risk gwNIPT. Thirty-three "missed cases" also had a 13-week scan, to which the various NT threshold values (3.0 mm, 1.6 MoM, 3.5 mm, and 1.9 MoM) were applied. In only 3 (9%) cases did the NT exceed 3.0 mm with similar detection rates (DR) for all higher cut-offs. Static and MoM-based NT cut-offs had similar positive predictive values (PPV). CONCLUSION: Enlarged NT measurement is a poor predictor of genetic abnormalities not identified by gwNIPT. When applied, the fixed NT cut-off of 3.5 mm provides a low FPR with a similar DR to lower cut-off thresholds, resulting in a higher PPV.
引用
- Han MP, Ferreira AEGMT, Elhindi J, et al. How Useful is Nuchal Translucency in Detecting Chromosomal Abnormalities Missed by Genome-Wide NIPT and What Measurement Threshold Should Be Used? Prenat Diagn. 2025. PMID: 39754320. doi:10.1002/pd.6742
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。