文献速递产科母胎医学

双胎妊娠生长不一致的纵向模式与不良围产结局

Longitudinal twin growth discordance patterns and adverse perinatal outcomes.
PubMed 文献 · Am J Obstet Gynecol · 2025-01-07

这项回顾性队列研究纳入2010至2023年伦敦一家三级医院分娩的823例双胎妊娠,用无监督机器学习识别出5种双胎生长不一致轨迹;高稳定型轨迹与复合不良围产结局风险显著升高相关(校正比值比76.44,95%CI 25.39-333.02),整合轨迹与分娩前最后一次超声脑胎盘比率不一致的模型预测效能最高(AUC 0.802)。

要点

  • 基于纵向超声的无监督聚类识别出低稳定、轻度下降、低上升、轻度上升和高稳定5种双胎生长不一致轨迹。
  • 高稳定型轨迹的围产儿发病率46.5%(40/86)和死亡率9.3%(8/86)显著高于低稳定型参照组(P<.001)。
  • 整合不一致轨迹与分娩前最后一次脑胎盘比率不一致的模型预测复合不良围产结局的AUC为0.802,优于单用轨迹或单次估重不一致。

核心结论

  • 无监督机器学习识别出5种不同的双胎胎儿生长不一致轨迹,持续高不一致与不良围产结局发生率升高相关,并呈剂量-反应关系。
  • 整合不一致轨迹与末次就诊时脑胎盘比率不一致的预测模型,对复合不良围产结局的预测效能优于两者单独使用或分娩前末次超声单次估重不一致值。

研究设计与样本

  • 回顾性队列研究,纳入2010至2023年在伦敦一家三级医院随访并分娩的双胎妊娠。
  • 纳入标准为18周后至少3次超声评估且分娩孕周超过34周;排除单羊膜囊双胎、双胎输血综合征、遗传或结构异常及数据不完整者。
  • 共分析823例双胎妊娠,其中双绒毛膜647例、单绒毛膜176例。
  • 采用多水平混合效应回归模型和无监督机器学习算法(k均值聚类)分析,预测模型以受试者工作特征曲线下面积、校准截距和斜率比较,并用重复交叉验证验证,显著性设定为P<.05。

主要发现

  • 聚类得到5种轨迹:低稳定型204例(24.8%)、轻度下降型171例(20.8%)、低上升型173例(21.0%)、轻度上升型189例(23.0%)、高稳定型86例(10.4%)。
  • 高稳定型簇的围产儿发病率46.5%(40/86)、死亡率9.3%(8/86),均显著高于低稳定型参照簇(P<.001)。
  • 高稳定型生长模式与复合不良围产结局风险显著升高相关:比值比70.19(95%CI 24.18-299.03,P<.001),校正比值比76.44(95%CI 25.39-333.02,P<.001)。
  • 整合不一致模式与分娩前末次超声脑胎盘比率不一致的模型AUC最高,为0.802(95%CI 0.712-0.892,P<.001)。
  • 其他模型AUC:仅不一致模式0.785(95%CI 0.697-0.873);分娩前末次超声双胎估重不一致0.677(95%CI 0.545-0.809);末次超声单次估重与脑胎盘比率不一致组合0.702(95%CI 0.586-0.818);末次超声单次脑胎盘比率不一致0.633(95%CI 0.515-0.751)。

临床怎么用

  • 原文结论未据此给出具体临床推荐。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

BACKGROUND: Growth discordance in twin pregnancies is associated with increased perinatal morbidity and mortality, yet the patterns of discordance progression and the utility of Doppler assessments remain underinvestigated. OBJECTIVE: The objective of this study was to conduct a longitudinal assessment of intertwin growth and Doppler discordance to identify possible distinct patterns and to investigate the predictive value of longitudinal discordance patterns for adverse perinatal outcomes in twin pregnancies. STUDY DESIGN: This retrospective cohort study included twin pregnancies followed and delivered at a tertiary hospital in London (United Kingdom) between 2010 and 2023. We included pregnancies with at least 3 ultrasound assessments after 18 weeks and delivery beyond 34 weeks' gestation. Monoamniotic twin pregnancies, pregnancies with twin-to-twin transfusion syndrome, genetic or structural abnormalities, or incomplete data were excluded. Data on chorionicity, biometry, Doppler indices, maternal characteristics and obstetrics, and neonatal outcomes were extracted from electronic records. Doppler assessment included velocimetry of the umbilical artery, middle cerebral artery, and cerebroplacental ratio. Intertwin growth discordance was calculated for each scan. The primary outcome was a composite of perinatal mortality and neonatal morbidity. Statistical analysis involved multilevel mixed effects regression models and unsupervised machine learning algorithms, specifically k-means clustering, to identify distinct patterns of intertwin discordance and their predictive value. Predictive models were compared using the area under the receiver operating characteristic curve, calibration intercept, and slope, validated with repeated cross-validation. Analyses were performed using R, with significance set at P<.05. RESULTS: Data from 823 twin pregnancies (647 dichorionic, 176 monochorionic) were analyzed. Five distinct patterns of intertwin growth discordance were identified using an unsupervised learning algorithm that clustered twin pairs based on the progression and patterns of discordance over gestation: low-stable (n=204, 24.8%), mild-decreasing (n=171, 20.8%), low-increasing (n=173, 21.0%), mild-increasing (n=189, 23.0%), and high-stable (n=86, 10.4%). In the high-stable cluster, the rates of perinatal morbidity (46.5%, 40/86) and mortality (9.3%, 8/86) were significantly higher compared to the low-stable (reference) cluster (P<.001). High-stable growth pattern was also associated with a significantly higher risk of composite adverse perinatal outcomes (odds ratio: 70.19, 95% confidence interval: 24.18-299.03, P<.001; adjusted odds ratio: 76.44, 95% confidence interval: 25.39-333.02, P<.001). The model integrating discordance pattern with cerebroplacental ratio discordance at the last ultrasound before delivery demonstrated superior predictive accuracy, evidenced by the highest area under the receiver operating characteristic curve of 0.802 (95% confidence interval: 0.712-0.892, P<.001), compared to only discordance patterns (area under the receiver operating characteristic curve: 0.785, 95% confidence interval: 0.697-0.873), intertwin weight discordance at the last ultrasound prior to delivery (area under the receiver operating characteristic curve: 0.677, 95% confidence interval: 0.545-0.809), combination of single measurements of estimated fetal weight and cardiopulmonary resuscitation discordance at the last ultrasound prior to delivery (area under the receiver operating characteristic curve: 0.702, 95% confidence interval: 0.586-0.818), and single measurement of cardiopulmonary resuscitation discordance only at the last ultrasound (area under the receiver operating characteristic curve: 0.633, 95% confidence interval: 0.515-0.751). CONCLUSION: Using an unsupervised machine learning algorithm, we identified 5 distinct trajectories of intertwin fetal growth discordance. Consistent high discordance is associated with increased rates of adverse perinatal outcomes, with a dose-response relationship. Moreover, a predictive model integrating discordance trajectory and cardiopulmonary resuscitation discordance at the last visit demonstrated superior predictive accuracy for the prediction of composite adverse perinatal outcomes, compared to either of these measurements alone or a single value of estimated fetal weight discordance at the last ultrasound prior to delivery.

来源:Am J Obstet Gynecol,查看原文。版权归原作者所有。

引用

  1. Prasad S, Ayhan I, Mohammed D, et al. Longitudinal twin growth discordance patterns and adverse perinatal outcomes. Am J Obstet Gynecol. 2025. PMID: 39788362. doi:10.1016/j.ajog.2024.12.029

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。