文献速递生殖医学

超声引导下宫腔镜子宫清除术用于稽留流产

Ultrasound-guided hysteroscopic uterine evacuation in cases of missed abortion.
PubMed 文献 · Fertil Steril · 2025-01-15

本文介绍一种超声引导下宫腔镜清除稽留流产妊娠物的逐步手术技术,强调识别并切除不同层次、观察胚胎与卵黄囊,以及无母体污染的直接取样。7例患者均成功获得胚胎与滋养层组织及细胞遗传学结果,无母体细胞污染,无术中并发症,随访无妊娠物残留或宫腔粘连,尝试妊娠者均成功且无并发症。

要点

  • 超声引导下宫腔镜可清除稽留流产妊娠物,并直视下获取胚胎与滋养层组织。
  • 7例患者均获得无母体细胞污染的胚胎与滋养层细胞遗传学结果。
  • 无术中并发症,随访无妊娠物残留或宫腔粘连,尝试妊娠者均成功。

核心结论

  • 超声引导下宫腔镜清除稽留流产具有无创性,可能比传统手术技术更安全。
  • 该技术允许比较滋养层与胚胎活检,并可能解决胎盘极种植前胚胎活检中的嵌合体等问题。
  • 与常规刮宫术相比,该技术的相对复杂性是潜在缺点。

研究设计与样本

  • 本文为逐步创新手术技术的教学视频,展示超声引导下宫腔镜子宫清除术,用于光学引导下的胚胎与滋养层活检。
  • 研究对象为稽留流产女性,伴或不伴不孕史或复发性妊娠丢失史;视频中纳入的7例患者同意视频发表及在线发布。
  • 稽留流产经阴道超声确认胎心消失诊断。

主要发现

  • 所有病例均获得光学识别的胚胎与滋养层组织及相应细胞遗传学结果,无母体细胞污染。
  • 无术中并发症。
  • 患者随访未发现妊娠物残留或宫腔粘连。
  • 所有尝试妊娠的患者均成功,无并发症。

关键数值与推荐

  • 在深度镇静下,经宫颈置入5-mm宫腔镜,以生理盐水(80-100 mm Hg)膨胀宫腔。
  • 通过直视与经腹超声识别种植部位,用宫腔镜剪刀打开妊娠囊并进入胚外腔。
  • 观察并评估卵黄囊与胚胎,用宫腔镜钳进行胚胎与绒毛取样。
  • 移除胚胎后,用宫腔镜钳和剪刀切除妊娠囊。

临床怎么用

  • 原文未据此给出推荐。

局限性

  • 与常规刮宫术相比,该技术的相对复杂性是潜在缺点。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

OBJECTIVE: To describe the hysteroscopic, ultrasound-guided removal of missed abortion products of conception, emphasizing identification and resection of the different layers, visualization of the embryo and yolk sac, and maternal contamination-free direct sampling of the embryo and trophoblast. DESIGN: Illustration of a step-by-step innovative ultrasound-guided surgical technique for uterine evacuation during optically directed embryo and trophoblast biopsy. SUBJECTS: Women with missed abortion, with or without a history of infertility or recurrent pregnancy loss. The 7 patients included in this video gave consent for publication of the video and posting of the video online including social media, the journal website, and scientific literature websites. EXPOSURE: Missed abortion was diagnosed by transvaginal ultrasound confirming loss of fetal heartbeat. After informed consent, the patient was brought to the operating room. Under deep sedation, a 5-mm hysteroscope was inserted transcervically, and the uterine cavity was distended with normal saline (80-100 mm Hg). The implantation site was identified by direct visualization and transabdominal ultrasound. The gestational sac was opened with hysteroscopic scissors, and the extracoelomic cavity was entered. The yolk sac and embryo were visualized and evaluated. Embryo and chorionic villi sampling were performed with hysteroscopic forceps. After removal of the embryo, resection of the gestational sac was accomplished with hysteroscopic forceps and scissors. MAIN OUTCOME MEASURES: Step-by-step educational video. RESULTS: Optically identified embryonic and trophoblastic tissue and the corresponding cytogenetic result were obtained in all cases, without maternal cell contamination. There were no intraoperative complications. Patients' follow-up revealed no cases of retained products of conception or intrauterine adhesions. All patients who attempted pregnancy were successful, without complications. CONCLUSION: Ultrasound-guided hysteroscopic removal of a missed abortion is noninvasive and potentially safer than conventional surgical techniques. It allows comparison of trophoblastic vs. embryo biopsy and resolution of, for example, mosaicism in placental pole preimplantation embryo biopsies. A potential disadvantage is the relative complexity of the procedure compared with routine dilation and curettage (1-5).

来源:Fertil Steril,查看原文。版权归原作者所有。

引用

  1. Rouleau JP, Hernández J, Martín-Vasallo P, et al. Ultrasound-guided hysteroscopic uterine evacuation in cases of missed abortion. Fertil Steril. 2025. PMID: 39818357. doi:10.1016/j.fertnstert.2025.01.005

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。