文献速递产科母胎医学

母亲眼动脉多普勒与子宫动脉多普勒、血流动力学指标及孕周的关系:前瞻性MATERA研究

Relationship of maternal ophthalmic artery Doppler with uterine artery Doppler, hemodynamic indices and gestational age: prospective MATERA study.
PubMed 文献 · Ultrasound Obstet Gynecol · 2025-01-20

前瞻性队列纳入150名孕11+0至23+6周孕妇,测量眼动脉(OA)和子宫动脉(UtA)多普勒及母体血流动力学。Log UtA-PI与OA-PI弱相关(r=-0.19),与OA-PSV比值弱相关(r=0.31);孕周与OA-PI无显著相关(r=0.14),与OA-PSV比值弱相关(r=-0.23),与UtA-PI强相关(r=-0.68)。OA指标观察者内重复性高,双眼间相关中至强。作者认为OA指标可作为子痫前期的独立预测指标。

要点

  • Log UtA-PI与OA-PI弱相关(r=-0.19),与OA-PSV比值弱相关(r=0.31)。
  • 孕周与OA-PI无显著相关(r=0.14),与OA-PSV比值弱相关(r=-0.23)。
  • OA-PI和OA-PSV比值观察者内重复性高,双眼间相关中至强。

核心结论

  • OA-PI和OA-PSV比值与UtA-PI及母体血流动力学参数弱相关或无相关,作者认为它们可作为子痫前期的独立预测指标。
  • 孕周对OA-PI和OA-PSV比值无临床相关影响,作者认为这些指标在孕11至23周之间任何时间测量无需调整。
  • OA多普勒指标观察者内重复性高,且左右眼之间强相关。

研究设计与样本

  • 前瞻性队列研究,采用分层随机抽样招募孕11+0至23+6周女性,最终150名纳入分析。
  • 每只眼由同一观察者测量OA-PI、第一收缩期峰值流速(PSV1)、第二收缩期峰值流速(PSV2)及PSV比值(PSV2/PSV1)两次,每侧UtA-PI也测量两次。
  • 使用超声心输出量监测仪(USCOM 1A)进行母体血流动力学评估。
  • 采用Pearson和Spearman秩相关系数评估变量间相关性,Bland-Altman图评估OA多普勒指标的观察者内重复性。

主要发现

  • Log UtA-PI与OA-PI弱相关(r=-0.19(95%CI,-0.34至-0.03),P=0.021),与OA-PSV比值弱相关(r=0.31(95%CI,0.15-0.45),P<0.001)。
  • 孕周与OA-PI无显著相关(r=0.14(95%CI,-0.03至0.29),P=0.097),与OA-PSV比值弱相关(r=-0.23(95%CI,-0.38至-0.07),P=0.004),与UtA-PI强相关(r=-0.68(95%CI,-0.76至-0.58),P<0.001)。
  • OA-PI或OA-PSV比值与母体血流动力学指标之间未见强相关。
  • 调整母亲年龄和体重指数后相关性未改变。
  • 同一眼内OA-PI和OA-PSV比值的观察者内重复性高;右眼与左眼之间OA-PI中度相关(r=0.63(95%CI,0.53-0.72),P<0.001),OA-PSV比值强相关(r=0.81(95%CI,0.75-0.86),P<0.001)。

临床怎么用

  • 作者认为OA-PI和OA-PSV比值可作为子痫前期的独立预测指标。
  • 作者认为这些指标可在孕11至23周之间任何时间测量而无需调整。

局限性

  • 原文未报告局限性

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

OBJECTIVES: To examine the relationship of ophthalmic artery (OA) Doppler indices with uterine artery (UtA) Doppler indices, selected maternal hemodynamic parameters and gestational age, and to evaluate the intraobserver reproducibility of OA Doppler indices. METHODS: This was a prospective cohort study of women recruited between 11 + 0 and 23 + 6 weeks' gestation using a stratified and random sampling approach to ensure adequate distribution across the gestational-age range. OA pulsatility index (PI), first peak systolic velocity (PSV1), second peak systolic velocity (PSV2) and peak systolic velocity ratio (PSV ratio), calculated as PSV2/PSV1, were measured twice in each eye by the same observer. UtA-PI was also measured twice on each side by the same observer. Maternal hemodynamic assessment was undertaken using an ultrasonic cardiac output monitor (USCOM 1A). Pearson's and Spearman's rank correlation coefficients were used to assess the correlations between variables, and Bland-Altman plots were used to evaluate the intraobserver reproducibility of OA Doppler indices. RESULTS: Of 194 women invited to participate in the study, 169 were eligible for inclusion, of whom 16 were excluded following an obstetric ultrasound scan and a further three owing to inadequate or incomplete OA or UtA Doppler assessment, leaving 150 women in the final analysis. Log UtA-PI had a weak correlation with both OA-PI (r = -0.19 (95% CI, -0.34 to -0.03), P = 0.021) and OA-PSV ratio (r = 0.31 (95% CI, 0.15-0.45), P < 0.001). The correlation between gestational age and OA-PI was non-significant (r = 0.14 (95% CI, -0.03 to 0.29), P = 0.097), and that between gestational age and OA-PSV ratio was weak (r = -0.23 (95% CI, -0.38 to -0.07), P = 0.004), as opposed to the strong correlation between gestational age and UtA-PI (r = -0.68 (95% CI, -0.76 to -0.58), P < 0.001). No strong correlations were observed between OA-PI or OA-PSV ratio and maternal hemodynamic indices. The correlations were unaltered by adjustment for maternal age and body mass index. The intraobserver reproducibility of OA-PI and OA-PSV ratio in the same eye was high. The correlation between the right and left eyes was moderate for OA-PI (r = 0.63 (95% CI, 0.53-0.72), P < 0.001) and strong for OA-PSV ratio (r = 0.81 (95% CI, 0.75-0.86), P < 0.001). CONCLUSIONS: OA-PI and OA-PSV ratio had a weak or no correlation with UtA-PI and maternal hemodynamic parameters, meaning that they can be used as independent predictors for pre-eclampsia. Gestational age had no clinically relevant effect on OA-PI and OA-PSV ratio, suggesting that these indices could be measured without adjustment at any time between 11 and 23 weeks' gestation. OA Doppler indices had high intraobserver reproducibility and were strongly correlated between the right and left eyes. © 2025 The Author(s). Ultrasound in Obstetrics & Gynecology published by John Wiley & Sons Ltd on behalf of International Society of Ultrasound in Obstetrics and Gynecology.

来源:Ultrasound Obstet Gynecol,查看原文。版权归原作者所有。

引用

  1. Ali S, Mukasa DC, Lukakamwa D, et al. Relationship of maternal ophthalmic artery Doppler with uterine artery Doppler, hemodynamic indices and gestational age: prospective MATERA study. Ultrasound Obstet Gynecol. 2025. PMID: 39831889. doi:10.1002/uog.29162

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。