冷刀环技术逐步宫腔镜治疗国际妇产科联盟3型子宫肌瘤
本文通过教学视频逐步演示冷刀环技术宫腔镜治疗国际妇产科联盟(FIGO)3型子宫肌瘤。患者为前壁29mm FIGO 3型肌瘤,术中先以最小肌层损伤打开「内膜-肌层窗」,再用冷刀环钝性分离纤维结缔组织桥识别正确剥离面,最后用电环切除已剥离并推入宫腔的肌壁间部分。肌瘤单次手术完全切除,术后第2天出院,3个月随访宫腔镜示宫腔完全恢复。
要点
- 冷刀环技术可用于FIGO 3型子宫肌瘤的宫腔镜治疗,旨在减少健康肌层损伤。
- 关键步骤包括打开「内膜-肌层窗」、冷刀环钝性分离假包膜、电环切除已剥离部分。
- 本例29mm前壁FIGO 3型肌瘤单次手术完全切除,3个月随访宫腔完全恢复。
核心结论
- 冷刀环技术有潜力安全切除FIGO 3型子宫肌瘤,减少对邻近健康肌层的损伤并降低术后粘连可能性,对有生育计划女性尤为重要。
研究设计与样本
- 采用教学视频逐步演示冷刀环技术,展示一例29mm前壁FIGO 3型子宫肌瘤的宫腔镜治疗。
主要发现
- 肌瘤经单次手术步骤完全切除,术毕肌瘤「切迹」及完整假包膜清晰可见。
- 患者术后次日健康状况良好出院。
- 术后3个月诊断性门诊宫腔镜检查示宫腔完全恢复。
关键数值与推荐
- FIGO 3型肌瘤具有完全肌层发育并侵及内膜,兼具黏膜下与肌壁间肌瘤特征。
- 传统宫腔镜入路的主要局限包括损伤健康肌层的风险及显著粘连风险。
- 视频强调的关键步骤为:以最小肌层牺牲打开「内膜-肌层窗」;用冷刀环钝性分离锚定肌瘤与假包膜的纤维结缔组织桥以识别正确剥离面;用电环切片已剥离并推入宫腔的肌壁间部分。
临床怎么用
- 原文未据此给出推荐。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
OBJECTIVE: To demonstrate the "cold loop technique" for the hysteroscopic treatment of International Federation of Gynaecology and Obstetrics (FIGO) type 3 myomas. DESIGN: Step-by-step demonstration of the technique using educative video. EXPOSURE: FIGO type 3 myomas exhibit complete myometrial development while encroaching on the endometrium. This hybrid nature, combining features of both submucous and intramural myomas, may have a detrimental "double hit" effect for patients seeking pregnancy. Currently, there is a dearth of robust evidence regarding the ideal surgical approach for FIGO type 3 myomas. Despite the preference for the hysteroscopic approach due to their closer proximity to the uterine cavity compared with the serosa, the primary limitations of the conventional hysteroscopic approach include the risks of damaging healthy myometrium and the significant risk of adhesions. We showcase the hysteroscopic treatment of a 29-mm FIGO type 3 myoma on the anterior uterine wall using the "cold loop technique." The video emphasizes key procedural phases: opening the "endometrial-myometrial window" with minimal sacrifice of myometrium; identifying the correct cleavage plane through blunt dissection of fibroconnective bridges anchoring the myoma to the pseudocapsule using cold loops; and slicing the detached intramural component of the fibroid, displaced into the uterine cavity, with an electrical loop. MAIN OUTCOME MEASURES: Integrity of the uterine cavity and the healthy myometrium surrounding the myoma and avoiding postsurgical intrauterine adhesions. RESULTS: The myoma was completely removed in a single surgical step, and at the end of the procedure, the myoma's "notch" and its intact pseudocapsule were clearly visible. The patient was discharged in good health the day after the surgery. At the 3-month follow-up, the diagnostic office hysteroscopy revealed a fully recovered uterine cavity. CONCLUSION: The "cold loop technique" holds the potential to facilitate the safe removal of FIGO type 3 myomas, minimizing the risk of damage to the adjacent healthy myometrium and resulting in a lower likelihood of postoperative adhesions. This is especially critical for women contemplating conception.
引用
- Mazzon I, Vitagliano A, Cicinelli E, et al. Step-by-step hysteroscopic treatment of International Federation of Gynaecology and Obstetrics type 3 myoma with the cold loop technique. Fertil Steril. 2024. PMID: 39733818. doi:10.1016/j.fertnstert.2024.12.025
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。