体外受精常规操作中序贯使用一次性器械的双酚蓄积评估
研究评估辅助生殖技术常规条件下一次性器械是否释放双酚及序贯使用是否蓄积。检测19种器械(31次评估)及9种组合中10种双酚浓度。双酚S和双酚A可从部分器械检出,但组合使用时未见蓄积。
要点
- 双酚S从100毫米培养皿(32±20皮克)和高安全精子麦管(3±1皮克)中持续检出。
- 无杀精剂避孕套中双酚S和双酚A分别为95±78皮克和83±49皮克。
- 模拟取卵的17件器械组合中双酚S为37±22皮克,组合使用未见蓄积。
核心结论
- 常规辅助生殖技术操作中部分一次性器械可释放少量双酚A和双酚S,但组合使用时未见蓄积。
研究设计与样本
- 评估19种单独一次性器械(31次评估)及9种模拟辅助生殖技术主要步骤的器械组合,按常规使用条件提取,采用在线固相萃取/液相色谱/质谱法测定10种双酚浓度。
主要发现
- 100毫米培养皿中双酚S为32±20皮克,高安全精子麦管中双酚S为3±1皮克。
- 无杀精剂避孕套中双酚S为95±78皮克,双酚A为83±49皮克。
- 单独检测时其他双酚未检出。
- 模拟避孕套内精液采集及处理的13件器械组合中双酚A为46±16皮克,双酚S为43±32皮克。
- 模拟精液采集、处理及冷冻的14件器械组合中双酚S为10±4皮克,模拟取卵的17件器械组合中双酚S为37±22皮克。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
RESEARCH QUESTION: Are bisphenols released from disposable devices used in assisted reproductive technology (ART) procedures, and do they accumulate when several disposable devices are used sequentially under routine conditions? DESIGN: A comprehensive assessment of 19 individual disposable devices (31 assessments) and nine combinations of disposable devices replicating the main steps in an ART procedure was undertaken. The extraction of bisphenols followed routine-use conditions (temperature and duration). The concentrations of 10 bisphenols were determined using online solid-phase extraction/liquid chromatography/mass spectrometry methodology. RESULTS: Bisphenol S (BPS) was quantified consistently from 100-mm culture dishes (32 ± 20 pg) and from high security sperm straws (3 ± 1 pg). Also, BPS and bisphenol A (BPA) were quantified consistently from spermicide-free condoms (95 ± 78 and 83 ± 49 pg, respectively). No other bisphenols were detected in disposable devices when tested individually. When disposable devices were used in combination, both BPA and BPS were detected consistently in combinations of 13 disposable devices mimicking sperm collection in a condom and its preparation (46 ± 16 and 43 ± 32 pg, respectively). BPS was quantified consistently in combinations of 14 disposable devices mimicking sperm collection, its preparation and freezing (10 ± 4 pg), and in combinations of 17 disposable devices mimicking oocyte retrieval (37 ± 22 pg). CONCLUSIONS: BPA and BPS are released in small quantities from some disposable devices used in routine conditions during ART procedures, but do not appear to accumulate when these disposable devices are used in combination.
引用
- Delaroche L, Besnard L, Cassuto NG, et al. Assessment of bisphenol accumulation from disposable devices used sequentially in IVF routine procedures. Reprod Biomed Online. 2024. PMID: 39602996. doi:10.1016/j.rbmo.2024.104431
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。