文献速递产科母胎医学

使用腹壁脂肪牵开器改善胎儿解剖结构可视化:一项随机对照试验

Panniculus Retractor Use for Visualization of Fetal Anatomy: A Randomized Controlled Trial.
PubMed 文献 · Obstet Gynecol · 2024-07-25

该随机对照试验纳入BMI≥40且存在腹壁脂肪下垂的孕妇150例,比较使用腹壁脂肪牵开器与常规护理对胎儿解剖检查完成率的影响。结果显示16个预设切面的完成率在牵开器组为25.7%(19/74),对照组为31.6%(24/76),差异无统计学意义(RR 0.81,95%CI 0.49-1.35)。患者和超声医师的满意度相似,牵开器耐受性良好但未提高检查完成率。

要点

  • 对于BMI≥40且腹壁脂肪下垂的孕妇,使用腹壁脂肪牵开器未提高16个预设胎儿解剖切面的完成率。
  • 牵开器组与常规护理组在次要结局(包括全部64个切面完成率、检查时长、主要胎儿异常检出率等)均无显著差异。
  • 患者和超声医师对牵开器的满意度与常规护理相似,牵开器耐受性良好。

核心结论

  • 在BMI≥40且存在腹壁脂肪下垂的孕妇中,胎儿解剖检查时使用腹壁脂肪牵开器患者和超声医师耐受性良好,但未提高16个预设胎儿解剖切面的完成率。

研究设计与样本

  • 随机对照试验,纳入BMI≥40且存在腹壁脂肪下垂的孕妇,随机分为牵开器组(74例)和常规护理组(76例),共150例完成研究。
  • 主要结局为胎儿解剖检查中16个预设切面的完成率;次要结局包括本院详细解剖检查全部64个切面的完成率、检查时长、主要胎儿异常检出率、牵开器放置前后皮肤至羊膜腔深度、患者和超声医师满意度及预设不良事件。
  • 假设基线完成率为23%,目标提高两倍,80%把握度,双侧α=0.05,计算样本量为132例,为考虑脱落将目标入组增至150例。

主要发现

  • 16个预设切面的完成率在牵开器组为25.7%(19/74),对照组为31.6%(24/76),RR 0.81(95%CI 0.49-1.35)。
  • 所有次要结局在两组间均无显著差异。
  • 患者满意度和超声医师满意度在两组间相似。
  • 除腹壁脂肪下垂分级外,两组基线特征相似。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

OBJECTIVE: To evaluate whether use of a panniculus retractor device for pregnant patients with body mass index (BMI) 40 or higher and a panniculus improves the completion rate of the fetal anatomic examination. METHODS: This was a randomized trial in which eligible patients with BMI 40 or higher and a panniculus were randomized to undergo their detailed fetal anatomic examination with a panniculus retractor device in place compared with usual care. The primary outcome was the completion rate of 16 prespecified views from the anatomic examination. Secondary outcomes included completion rate of all 64 views from our institution's detailed anatomic examination, duration of examination, major fetal anomaly detection rate, depth from the skin to amniotic cavity before and after retractor placement, patient and ultrasonographer satisfaction, and prespecified adverse events. We assumed a baseline completion rate of 23% for the primary outcome and targeted a twofold improvement with 80% power and two-sided α of 0.05, which resulted in a sample size of 132 participants. The goal enrollment was increased to 150 participants to account for potential dropout. Statistical tests included the Student's t test, χ 2 , and relative risks (RRs) as appropriate. RESULTS: From March to July of 2023, 150 participants completed the study: 74 in the retractor group and 76 in the usual care group. Baseline characteristics were similar between groups except for panniculus grade. The completion rate of 16 prespecified views was 25.7% (19/74) in the retractor group and 31.6% (24/76) in the control group (RR 0.81, 95% CI, 0.49-1.35). There were no significant differences between groups for any of the secondary outcomes. Patient satisfaction and ultrasonographer satisfaction were similar between groups. CONCLUSION: Use of a panniculus retractor device during the fetal anatomic examination for patients with BMI 40 or higher and a panniculus was well tolerated by patients and ultrasonographers but did not improve the completion rate of 16 prespecified fetal anatomic views. CLINICAL TRIAL REGISTRATION: ClinicalTrials.gov , NCT05764408.

来源:Obstet Gynecol,查看原文。版权归原作者所有。

引用

  1. Wise ML, Okon M, Pratt KN, et al. Panniculus Retractor Use for Visualization of Fetal Anatomy: A Randomized Controlled Trial. Obstet Gynecol. 2024. PMID: 39053011. doi:10.1097/AOG.0000000000005689

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。