文献速递母胎医学产科

开放式与胎儿镜产前脊柱裂修补术中的胎儿心动过缓比较

Fetal bradycardia in open versus fetoscopic prenatal repair of spina bifida.
PubMed 文献 · Prenat Diagn · 2024-06-14

单机构回顾性队列研究比较2017至2022年开放式(n=25)与胎儿镜(n=26)脊柱裂修补术中胎儿心动过缓的发生情况,术中每15分钟超声记录胎心率。开放式手术组胎心率<110 bpm的心动过缓发生率显著高于胎儿镜组(32% vs. 3.8%,p=0.008),胎心率较基线下降>25 bpm有趋势(20% vs. 3.8%,p=0.073);严重心动过缓<80 bpm罕见,仅3例手术出现,2例胎儿需紧急剖宫产。

要点

  • 开放式修补组胎心率<110 bpm的心动过缓发生率为32%,胎儿镜组为3.8%(p=0.008)。
  • 胎心率较基线下降>25 bpm者开放式组20%、胎儿镜组3.8%(p=0.073),仅呈趋势。
  • 胎心率<80 bpm的严重心动过缓仅3例手术出现,2例胎儿需紧急剖宫产。

核心结论

  • 与开放式胎儿手术相比,胎儿镜手术中胎儿心动过缓发生频率更低,尽管胎儿镜手术的麻醉暴露显著更大且使用了羊膜腔内二氧化碳吹入。

研究设计与样本

  • 单机构回顾性队列研究,纳入2017年至2022年接受开放式(n=25)或胎儿镜(n=26)脊柱裂修补术的患者。
  • 2017年10月至2020年6月采用开放式经典子宫切开术进行修补,2020年11月至2022年6月转为胎儿镜技术后进行胎儿镜修补。
  • 术中每15分钟通过超声心动图记录胎心率(bpm),比较两组队列特征、胎儿心动过缓和母体生理参数。

主要发现

  • 开放式修补组胎儿更常发生胎心率<110 bpm的心动过缓(32% vs. 3.8%,p=0.008)。
  • 胎心率较基线下降>25 bpm存在趋势(20% vs. 3.8%,p=0.073)。
  • 胎心率<80 bpm的严重心动过缓罕见,仅3例手术出现(开放式2例,胎儿镜1例),2例胎儿(每组各1例)需紧急剖宫产。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

OBJECTIVE: To compare the occurrence of fetal bradycardia in open versus fetoscopic fetal spina bifida surgery. METHODS: This is a single-institution retrospective cohort study of patients undergoing open (n = 25) or fetoscopic (n = 26) spina bifida repair between 2017 and 2022. From October 2017 to June 2020, spina bifida repairs were performed via an open classical hysterotomy, and from November 2020 to June 2022 fetoscopic repairs were performed following transition to this technique. Fetal heart rate (FHR) in beats per minute (bpm) was recorded via echocardiography every 15 min during the procedure. Cohort characteristics, fetal bradycardia and maternal physiologic parameters were compared between the groups. RESULTS: Fetuses undergoing an open repair more frequently developed bradycardia defined as <110 bpm (32% vs. 3.8%, p = 0.008), and a trend was observed for FHR decreases more than 25 bpm from baseline (20% vs. 3.8%, p = 0.073). Profound bradycardia less than 80 bpm was rare, occurring in only three operations (two in open, one in fetoscopic repair) with two fetuses (one in each group) requiring emergency cesarean delivery. CONCLUSION: When compared to open fetal surgery, fetal bradycardia occurred less frequently in fetoscopic surgery despite a significantly greater anesthetic exposure and the use of the intraamniotic carbon dioxide insufflation.

来源:Prenat Diagn,查看原文。版权归原作者所有。

引用

  1. Papastefan ST, Alhajjat AM, Ott KC, et al. Fetal bradycardia in open versus fetoscopic prenatal repair of spina bifida. Prenat Diagn. 2024. PMID: 38877305. doi:10.1002/pd.6626

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。