优化移植方案可减轻胚胎移植过程中的温度波动
本研究通过模拟胚胎移植,测试气流/移动、导管覆盖物及工作站类型对导管温度的影响,并监测培养皿pH波动。结果显示,导管未覆盖时运输中冷却更快,覆盖塑料管、纸或纸+拇指可维持较高温度;在 crib 中装载导管仅在其停留期间改善温度稳定性,并减少操作中pH波动。
要点
- 导管未覆盖时运输中冷却速率快于所有覆盖方法(均P<0.05)。
- TL+20秒时未覆盖导管温度28.43±0.30°C,低于塑料管覆盖31.4±0.30°C、纸覆盖31.0±0.26°C、纸+拇指覆盖31.1±0.78°C(均P≤0.05)。
- crib装载导管仅在导管停留crib期间改善温度稳定性,运输期间降温速率与加热台相似;crib中操作时培养皿pH波动小于加热台。
核心结论
- 通过缩短运输时间和使用导管覆盖物可减轻胚胎移植过程中的温度丢失。
- 使用crib装载导管仅在导管停留crib期间改善温度稳定性,运输期间无改善,但可减少操作中pH波动。
研究设计与样本
- 模拟胚胎移植实验,测试气流/移动、导管覆盖物及装载工作站类型对导管温度的影响。
- 将热电偶探头插入外导管尖端或贴于内导管外壁,从模拟装载时刻(TL)至TL+60秒或从运输开始(TT)每5秒记录导管内温度。
- 监测胚胎移植皿中培养液pH波动。
主要发现
- 导管未覆盖时运输中冷却速率快于所有覆盖方法(均P<0.05)。
- TL+20秒时未覆盖导管温度28.43±0.30°C,低于塑料管覆盖31.4±0.30°C、纸覆盖31.0±0.26°C、纸+拇指覆盖31.1±0.78°C(均P≤0.05)。
- 在crib中装载导管较加热台更有效维持温度,直至运输开始,之后降温速率相似。
- 操作中胚胎移植皿留在加热台时培养液pH升高快于开放crib。
临床怎么用
- 原文未据此给出推荐。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
RESEARCH QUESTION: What impact do variations in embryo transfer catheter loading and movement procedures have on temperature and pH fluctuations during embryo transfer? DESIGN: Mock embryo transfers were conducted to test the impact of air flow/movement, use of catheter coverings, and the type of workstation used for catheter loading on catheter temperature. A thermocouple probe inserted into the tip of the outer catheter or taped to the exterior of the inner catheter recorded temperature within the catheter every 5 s from time of mock embryo loading (TL) to 60 s (TL + 60 s) or from the start of transit (TT). Fluctuations in culture medium pH in embryo transfer dishes were monitored. RESULTS: The rate of cooling during transit was faster (all P < 0.05) when catheters were uncovered compared with all covering methods tested. This resulted in a lower catheter temperature at TL + 20 s (28.43 ± 0.30 °C) compared with catheters covered by plastic tubing (31.4 ± 0.30 °C), paper (31.0 ± 0.26 °C) or paper + thumb (31.1 ± 0.78 °C; all P ≤ 0.05). Temperature was maintained more effectively when catheters were loaded in a crib compared with a heated stage, until initiation of transit, when the rate of temperature decrease was similar. Culture medium pH increased more rapidly when embryo transfer dishes remained on a heated stage during the procedure compared with in an open crib. CONCLUSIONS: Temperature loss during the embryo transfer procedure can be mitigated by reducing the transit time and using catheter coverings. Use of a crib for catheter loading only improved temperature stability while the catheter remained in the crib, not during transit, and reduced pH fluctuations during the procedure.
引用
- Gurner KH, Kelley RL, Lee LYS, et al. Temperature fluctuations during embryo transfer can be mitigated by optimizing transfer protocol. Reprod Biomed Online. 2024. PMID: 38657328. doi:10.1016/j.rbmo.2024.103847
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。