文献速递母胎医学产科

供血儿大脑中动脉收缩期峰值流速升高与双胎输血综合征中供血儿死亡风险的关系(排除双胎贫血-红细胞增多序列征)

Elevated middle cerebral artery peak systolic velocity and risk of death in donor twin affected by twin-twin transfusion syndrome but not twin anemia-polycythemia sequence.
PubMed 文献 · Ultrasound Obstet Gynecol · 2024-06-22

该前瞻性队列研究纳入2011至2022年单中心接受激光手术的507例双胎输血综合征(排除双胎贫血-红细胞增多序列征)病例,发现供血儿大脑中动脉收缩期峰值流速升高(>1.5中位数倍数)是供血儿胎死宫内的独立危险因素(校正相对风险4.52,95%CI 2.72-7.50),且供血儿流速升高组低搏动指数比例高于正常组(33.3% vs 15.5%,P=0.016)。

要点

  • 供血儿大脑中动脉收缩期峰值流速升高是供血儿胎死宫内的独立危险因素(校正相对风险4.52)。
  • 在Quintero II期和III期中,供血儿流速升高与供血儿死亡独立相关(校正相对风险分别为14.21和3.41)。
  • 供血儿流速升高组低搏动指数比例高于正常组(33.3% vs 15.5%,P=0.016)。

核心结论

  • 激光手术前无双胎贫血-红细胞增多序列征的供血儿大脑中动脉收缩期峰值流速升高与供血儿胎死宫内风险增加约4倍相关,校正了选择性胎儿生长受限、双胎输血综合征分期和其他混杂因素。
  • 激光手术前供血儿大脑中动脉收缩期峰值流速的多普勒评估可能有助于对双胎输血综合征分期进行分层以评估供血儿胎死宫内的风险。

研究设计与样本

  • 前瞻性队列研究,纳入2011至2022年单中心接受激光手术的双胎输血综合征病例,排除双胎贫血-红细胞增多序列征病例。
  • 共660例双胎输血综合征病例,48例(7.3%)未记录供血儿大脑中动脉收缩期峰值流速,剩余612例中9例(1.5%)失访、96例双胎贫血-红细胞增多序列征被排除,最终纳入507例。
  • 采用多变量和泊松回归分析探讨孤立性供血儿大脑中动脉收缩期峰值流速升高与胎死宫内的关联,校正双胎输血综合征分期、选择性胎儿生长受限和其他混杂因素。

主要发现

  • 供血儿大脑中动脉收缩期峰值流速升高见于6.5%(33/507)的病例,是供血儿胎死宫内的独立危险因素(校正相对风险4.52,95%CI 2.72-7.50)。
  • 按Quintero分期分层,供血儿流速升高是Quintero II期(校正相对风险14.21,95%CI 1.09-186.2)和III期(校正相对风险3.41,95%CI 1.82-6.41)供血儿胎死宫内的独立危险因素。
  • 供血儿大脑中动脉收缩期峰值流速的中位数倍数与供血儿胎死宫内相关(受试者工作特征曲线下面积0.69,P<0.001),而受血儿流速的中位数倍数与受血儿胎死宫内无关(曲线下面积0.54,P=0.44)。
  • 供血儿流速升高组中低大脑中动脉搏动指数的供血儿比例高于流速正常组(33.3% vs 15.5%,P=0.016)。

临床怎么用

  • 激光手术前对供血儿大脑中动脉收缩期峰值流速进行多普勒评估可能有助于对双胎输血综合征分期进行分层以评估供血儿胎死宫内的风险。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

OBJECTIVES: To determine the association between elevated (> 1.5 multiples of the median (MoM)) middle cerebral artery (MCA) peak systolic velocity (PSV) and fetal demise of the donor twin in pregnancies complicated by twin-twin transfusion syndrome (TTTS) in the absence of twin anemia-polycythemia sequence (TAPS). Secondary objectives were to evaluate if donor or recipient MCA-PSV is associated with a risk for their corresponding fetal death, and to compare the proportion of donor fetuses with low MCA pulsatility index (PI) among donor twins with high MCA-PSV and those with normal MCA-PSV to evaluate the contribution of blood-flow redistribution to the fetal brain in donor twins with high MCA-PSV. METHODS: This prospective cohort study included TTTS cases that underwent laser surgery between 2011 and 2022 at a single center. TAPS cases were excluded from the study. Multivariable and Poisson regression analysis were performed to explore the association between isolated elevated donor MCA-PSV and fetal demise, adjusted for TTTS stage, selective fetal growth restriction (sFGR) and other confounders. RESULTS: Of 660 TTTS cases, donor MCA-PSV was not recorded in 48 (7.3%) cases. Of the remaining 612 patients, nine (1.5%) were lost to follow-up and 96 TAPS cases were excluded; thus, 507 cases were included in the study. High donor MCA-PSV was seen in 6.5% (33/507) of cases and was an independent risk factor for donor fetal demise (adjusted relative risk (aRR), 4.52 (95% CI, 2.72-7.50)), after adjusting for confounders. Regression analysis restricted to each Quintero TTTS stage demonstrated that high donor MCA-PSV was an independent risk factor for fetal demise of the donor in Quintero Stage II (aRR, 14.21 (95% CI, 1.09-186.2)) and Quintero Stage III (aRR, 3.41 (95% CI, 1.82-6.41)). Donor MCA-PSV in MoM was associated with fetal demise of the donor (area under the receiver-operating-characteristics curve (AUC), 0.69; P < 0.001), but recipient MCA-PSV in MoM was not associated with fetal demise of the recipient (AUC, 0.54; P = 0.44). A higher proportion of donor twins in the group with high MCA-PSV had a low MCA-PI compared to the group with normal MCA-PSV (33.3% vs 15.5%; P = 0.016). CONCLUSIONS: Elevated donor MCA-PSV without TAPS prior to laser surgery for TTTS is associated with a 4-fold increased risk for donor fetal demise, adjusted for sFGR, TTTS stage and other confounders. Doppler evaluation of donor MCA-PSV prior to laser surgery may help stratify TTTS staging to evaluate the risk of donor fetal demise. © 2024 International Society of Ultrasound in Obstetrics and Gynecology.

来源:Ultrasound Obstet Gynecol,查看原文。版权归原作者所有。

引用

  1. Espinoza J, Agarwal N, Johnson A, et al. Elevated middle cerebral artery peak systolic velocity and risk of death in donor twin affected by twin-twin transfusion syndrome but not twin anemia-polycythemia sequence. Ultrasound Obstet Gynecol. 2024. PMID: 38437460. doi:10.1002/uog.27629

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。