文献速递产科

OdonAssist可充气装置用于辅助阴道分娩的安全性和有效性:BESANCON ASSIST研究

Safety and efficacy of the OdonAssist inflatable device for assisted vaginal birth: the BESANCON ASSIST study.
PubMed 文献 · Am J Obstet Gynecol · 2023-08-01

在法国贝桑松大学医院开展开放标签非随机研究,104名有临床指征的辅助阴道分娩产妇使用OdonAssist,成功率为88.5%(92/104),无急诊剖宫产,无器械相关严重母婴不良反应,会阴三度和四度裂伤率3.8%(4/104)。

要点

  • OdonAssist辅助阴道分娩成功率88.5%(92/104),无急诊剖宫产。
  • 无器械相关严重母婴不良反应,会阴三度和四度裂伤率3.8%(4/104)。
  • 产妇对分娩体验感知评分高,操作者对该装置感知积极且各步骤易用。

核心结论

  • OdonAssist是当前其他辅助阴道分娩装置的安全有效替代选择。
  • 孕妇中83%(1636/1973)的接受率及OdonAssist高辅助阴道分娩成功率证实未来开展随机对照试验的可行性。

研究设计与样本

  • 开放标签、非随机研究,纳入法国贝桑松大学医院104名有临床指征并使用OdonAssist行辅助阴道分娩的产妇。
  • 数据包括嵌套队列组,该组产妇因分娩时无受训的OdonAssist装置操作员而使用负压或产钳行辅助阴道分娩。
  • 主要结局指标为使用OdonAssist成功辅助阴道分娩的比例。
  • 新生儿结局数据在第1天和第28天评估,产妇结局随访至第90天。
  • 2019年12月至2021年5月期间接触2191名孕妇,其中83%(1636/1973)同意参与研究。

主要发现

  • 1636名参与者中,10.7%(176/1636)因胎头位于+1及以下需要辅助阴道分娩。
  • 176名需辅助阴道分娩者中,59%(104/176)使用OdonAssist,41.1%(72/176)纳入嵌套队列组。
  • 使用OdonAssist成功辅助阴道分娩率为88.5%(92/104)。
  • OdonAssist组未行急诊剖宫产,无与装置使用相关的严重产妇或新生儿不良反应。
  • OdonAssist会阴三度和四度裂伤率为3.8%(4/104);产妇使用15分制量表在第1、7、28天对分娩体验的感知评分高,操作者报告对该装置感知积极且各步骤易用。

临床怎么用

  • 作者认为OdonAssist是当前其他辅助阴道分娩装置的安全有效替代选择。
  • 作者认为孕妇高接受率(83%)及OdonAssist高辅助阴道分娩成功率证实未来随机对照试验的可行性。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

BACKGROUND: The first feasibility study of the OdonAssist inflatable device for use in clinically indicated assisted vaginal birth reported a success rate of 48% with no significant safety concerns. Additional studies exploring the device performance in other clinical settings are warranted before definitive conclusions can be drawn about its safety and efficacy in current practice. OBJECTIVE: This study aimed to investigate the safety and efficacy of the OdonAssist before conducting a randomized controlled trial. STUDY DESIGN: This was an open-label, nonrandomized study of 104 women with a clinically indicated assisted vaginal birth using the OdonAssist at the Besancon University Hospital, France. Data, including those of a nested cohort group of women who had an assisted vaginal birth using vacuum or spatulas because a trained OdonAssist device operator was not available at the time of delivery, were collected. The primary outcome measure was the proportion of successful assisted vaginal births using the OdonAssist. Neonatal outcome data were reviewed at days 1 and 28, and maternal outcomes were investigated up to day 90. RESULTS: Between December 2019 and May 2021, 2191 pregnant women were approached, and 83% (1636/1973) of them consented to participate in the study. Among them, 10.7% (176/1636) required an assisted vaginal birth owing to a vertex presentation at +1 and below. The OdonAssist was used in 59% of births (104/176), and 41.1% (72/176) of the participants were included in the nested cohort group. The rate of successful assisted vaginal births using the OdonAssist was 88.5% (92/104). No emergency cesarean deliveries were performed in the OdonAssist group. There were no serious adverse maternal or neonatal reactions related to the use of the device. The rate of third- and fourth-degree perineal tears with the OdonAssist was 3.8% (4/104). The maternal perception ratings of the birth experience with the OdonAssist (collected on days 1, 7, and 28 using a 15-point scale) were high. In addition, the operators reported a positive perception of the device, with ease of use across the different steps of the procedure. One single technique was used for all vertex fetal head positions. CONCLUSION: The OdonAssist is a safe and effective alternative to other current devices for assisted vaginal births. The high acceptance rate (83%) among pregnant women and the high rate of successful assisted vaginal births using the OdonAssist confirm the feasibility of a future randomized controlled trial.

来源:Am J Obstet Gynecol,查看原文。版权归原作者所有。

引用

  1. Mottet N, Hotton E, Eckman-Lacroix A, et al. Safety and efficacy of the OdonAssist inflatable device for assisted vaginal birth: the BESANCON ASSIST study. Am J Obstet Gynecol. 2023. PMID: 38462265. doi:10.1016/j.ajog.2023.05.016

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。