文献速递产科

床旁血糖检测在妊娠期糖尿病评估中的临床效用:前瞻性队列研究

Clinical utility of point-of-care glucose testing in the assessment of gestational diabetes: Prospective cohort study.
PubMed 文献 · BJOG · 2024-03-18

该前瞻性队列研究纳入2020年3月至6月在国王学院医院接受妊娠期糖尿病筛查的230名孕妇,比较床旁StatStrip®毛细血管血糖与实验室静脉血浆血糖在口服葡萄糖耐量试验中的诊断效能,发现床旁检测不能完全替代实验室方法,但在空腹≤5.0 mmol/L或2小时<7.5/>9.5 mmol/L时可排除或确认妊娠期糖尿病。

要点

  • 床旁StatStrip®检测空腹血糖敏感度88%、特异度97%,2小时血糖敏感度97%、特异度79%。
  • 空腹≤5.0 mmol/L或2小时<7.5 mmol/L时,床旁检测特异度和阴性预测值均为100%。
  • 2小时血糖>9.5 mmol/L时,床旁检测敏感度和阳性预测值均为100%。

核心结论

  • 在本队列中,床旁毛细血管血糖检测不能完全替代实验室方法用于口服葡萄糖耐量试验,但在空腹≤5.0 mmol/L或2小时<7.5/>9.5 mmol/L时可排除或确认妊娠期糖尿病。

研究设计与样本

  • 前瞻性队列研究,纳入2020年3月至6月在国王学院医院产前门诊接受妊娠期糖尿病筛查的230名孕妇。
  • 床旁毛细血管血糖采用StatStrip®检测,静脉血浆血糖采用Roche分析仪(Cobas 8000 c702)检测,妊娠期糖尿病诊断依据2015年美国国家卫生与临床优化研究所(NICE)临床指南标准。

主要发现

  • 床旁StatStrip®检测空腹血糖高于妊娠期糖尿病阈值者15例(6.5%),实验室静脉血浆血糖为8例(3.4%);2小时血糖高于阈值者分别为105例(45.6%)和72例(31.1%)。
  • 床旁StatStrip®检测空腹血糖敏感度88%(95%CI 52%-99%)、特异度97%(95%CI 93%-98%);2小时血糖敏感度97%(95%CI 91%-99%)、特异度79%(95%CI 71%-84%)。
  • 空腹≤5.0 mmol/L或2小时<7.5 mmol/L时,床旁StatStrip®检测的特异度和阴性预测值均为100%;2小时血糖>9.5 mmol/L时,敏感度和阳性预测值均为100%。

临床怎么用

  • 作者结论认为床旁毛细血管血糖检测不能完全替代实验室方法用于口服葡萄糖耐量试验,但在空腹≤5.0 mmol/L或2小时<7.5/>9.5 mmol/L时可排除或确认妊娠期糖尿病。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

OBJECTIVE: To assess the clinical utility of point-of-care (POC) capillary blood glucose (CBG) testing in the assessment of gestational diabetes mellitus (GDM) during oral glucose tolerance test (OGTT). DESIGN: Prospective cohort study. SETTING: Antenatal clinics at King's College Hospital. POPULATION: Women screened for GDM between March and June 2020. METHODS: The CBG was measured using the POC StatStrip® test and the venous plasma glucose (VPG) was measured by Roche analyser (Cobas 8000 c702). GDM was diagnosed based on the 2015 National Institute for Health and Clinical Excellence (NICE) Clinical Guideline criteria. The two methods were compared statistically using Analyse-It 5.40.2. MAIN OUTCOME MEASURES: Diagnostic sensitivity, specificity, positive and negative predictive values (PPV and NPV) for the POC StatStrip® test, compared with VPG measured by reference laboratory method. RESULTS: A total of 230 women were included. The number and percentage of women with glucose concentrations above the GDM threshold using the POC StatStrip® test versus laboratory VPG measurement was 15 (6.5%) versus eight (3.4%) at fasting and 105 (45.6%) versus 72 (31.1%) at 2 h, respectively. The sensitivity and specificity values (and 95% CIs) for the POC StatStrip® test were 88% (52%-99%) and 97% (93%-98%) at fasting and 97% (91%-99%) and 79% (71%-84%) at 2 h, respectively. However, the specificity and the NPV for the POC StatStrip® test for concentrations of ≤5.0 mmol/L at fasting or <7.5 mmol/L at 2 h were 100%, and the sensitivity and the PPV for concentrations of >9.5 mmol/L at 2 h were 100%. CONCLUSIONS: In our cohort the POC measurement of CBG cannot entirely replace the laboratory method for the OGTT; however, it can be used to rule out/rule in GDM for glucose concentrations of ≤5.0 mmol/L at fasting or <7.5/>9.5 mmol/L at 2 h.

来源:BJOG,查看原文。版权归原作者所有。

引用

  1. Al-Hasani W, Ranasinghe R, Rogers H, et al. Clinical utility of point-of-care glucose testing in the assessment of gestational diabetes: Prospective cohort study. BJOG. 2024. PMID: 38497098. doi:10.1111/1471-0528.17811

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。