文献速递产科

基于宫口扩张与胎头位置的新产程曲线提高产程进展预测准确性

New labor curves of dilation and station to improve the accuracy of predicting labor progress.
PubMed 文献 · Am J Obstet Gynecol · 2024-02-28

本研究基于8022例初产妇的纵向队列数据,比较单因素(时间)与多因素模型预测宫口扩张和胎头位置的误差。多因素机器学习模型的平均绝对误差为0.826 cm,显著低于单因素模型的2.122 cm(P<.0001),平均预测误差降低超过50%,外部验证结果相似。

要点

  • 多因素机器学习模型预测宫口扩张的平均绝对误差为0.826 cm,单因素模型为2.122 cm(P<.0001)。
  • 多因素混合效应模型平均绝对误差为0.893 cm,亦低于单因素模型(P<.0001)。
  • 多因素机器学习胎头下降曲线平均绝对误差为0.512 cm,均方根误差为0.660 cm。

核心结论

  • 基于多个临床相关参数的宫口扩张模型较仅基于时间的模型预测误差更低,平均预测误差降低超过50%。
  • 更准确地评估宫口扩张和胎头位置偏离预期值可能有助于临床医生优化产程管理。

研究设计与样本

  • 纵向队列研究,纳入8022例初产妇,均为单胎、头先露、孕周≥35周且经阴道分娩的活产儿。
  • 采用10折交叉验证生成新的宫口扩张和胎头位置产程曲线,并使用地理独立组进行外部验证。
  • 模型变量包括分娩前20小时内首次检查后的时间、前次检查记录的宫口扩张、宫颈管消退和胎头位置、累计宫缩次数、硬膜外麻醉使用和引产使用。
  • 采用混合效应回归(标准统计方法)和高斯过程(机器学习方法)两种建模方法,通过平均绝对误差和均方根误差评估预测误差。

主要发现

  • 多因素机器学习宫口扩张模型平均绝对误差为0.826 cm(95%CI 0.820-0.832),多因素混合效应模型为0.893 cm(95%CI 0.885-0.901),单因素模型为2.122 cm(95%CI 2.108-2.136),两种多因素模型与单因素模型比较P均<.0001。
  • 多因素机器学习宫口扩张模型均方根误差为1.126 cm(95%CI 1.118-1.133,P<.0001),多因素混合效应模型为1.172 cm(95%CI 1.164-1.181,P<.0001),单因素模型为2.504 cm(95%CI 2.487-2.521)。
  • 多因素机器学习宫口扩张模型较混合效应回归模型准确性有小幅但统计学显著的改善(P<.0001)。
  • 多因素机器学习胎头下降曲线平均绝对误差为0.512 cm(95%CI 0.509-0.515),均方根误差为0.660 cm(95%CI 0.655-0.666)。
  • 使用独立数据进行外部验证得到类似结果。

关键数值与推荐

  • 多因素机器学习宫口扩张模型平均绝对误差0.826 cm(95%CI 0.820-0.832)。
  • 多因素混合效应宫口扩张模型平均绝对误差0.893 cm(95%CI 0.885-0.901)。
  • 单因素宫口扩张模型平均绝对误差2.122 cm(95%CI 2.108-2.136)。
  • 多因素机器学习胎头下降曲线平均绝对误差0.512 cm(95%CI 0.509-0.515),均方根误差0.660 cm(95%CI 0.655-0.666)。

临床怎么用

  • 更准确地评估宫口扩张和胎头位置偏离预期值可能有助于临床医生优化产程管理。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

BACKGROUND: The diagnosis of failure to progress, the most common indication for intrapartum cesarean delivery, is based on the assessment of cervical dilation and station over time. Labor curves serve as references for expected changes in dilation and fetal descent. The labor curves of Friedman, Zhang et al, and others are based on time alone and derived from mothers with spontaneous labor onset. However, labor induction is now common, and clinicians also consider other factors when assessing labor progress. Labor curves that consider the use of labor induction and other factors that influence labor progress have the potential to be more accurate and closer to clinical decision-making. OBJECTIVE: This study aimed to compare the prediction errors of labor curves based on a single factor (time) or multiple clinically relevant factors using two modeling methods: mixed-effects regression, a standard statistical method, and Gaussian processes, a machine learning method. STUDY DESIGN: This was a longitudinal cohort study of changes in dilation and station based on data from 8022 births in nulliparous women with a live, singleton, vertex-presenting fetus ≥35 weeks of gestation with a vaginal delivery. New labor curves of dilation and station were generated with 10-fold cross-validation. External validation was performed using a geographically independent group. Model variables included time from the first examination in the 20 hours before delivery; dilation, effacement, and station recorded at the previous examination; cumulative contraction counts; and use of epidural anesthesia and labor induction. To assess model accuracy, differences between each model's predicted value and its corresponding observed value were calculated. These prediction errors were summarized using mean absolute error and root mean squared error statistics. RESULTS: Dilation curves based on multiple parameters were more accurate than those derived from time alone. The mean absolute error of the multifactor methods was better (lower) than those of the single-factor methods (0.826 cm [95% confidence interval, 0.820-0.832] for the multifactor machine learning and 0.893 cm [95% confidence interval, 0.885-0.901] for the multifactor mixed-effects method and 2.122 cm [95% confidence interval, 2.108-2.136] for the single-factor methods; P<.0001 for both comparisons). The root mean squared errors of the multifactor methods were also better (lower) than those of the single-factor methods (1.126 cm [95% confidence interval, 1.118-1.133] for the machine learning [P<.0001] and 1.172 cm [95% confidence interval, 1.164-1.181] for the mixed-effects methods and 2.504 cm [95% confidence interval, 2.487-2.521] for the single-factor [P<.0001 for both comparisons]). The multifactor machine learning dilation models showed small but statistically significant improvements in accuracy compared to the mixed-effects regression models (P<.0001). The multifactor machine learning method produced a curve of descent with a mean absolute error of 0.512 cm (95% confidence interval, 0.509-0.515) and a root mean squared error of 0.660 cm (95% confidence interval, 0.655-0.666). External validation using independent data produced similar findings. CONCLUSION: Cervical dilation models based on multiple clinically relevant parameters showed improved (lower) prediction errors compared to models based on time alone. The mean prediction errors were reduced by more than 50%. A more accurate assessment of departure from expected dilation and station may help clinicians optimize intrapartum management.

来源:Am J Obstet Gynecol,查看原文。版权归原作者所有。

引用

  1. Hamilton EF, Zhoroev T, Warrick PA, et al. New labor curves of dilation and station to improve the accuracy of predicting labor progress. Am J Obstet Gynecol. 2024. PMID: 38423450. doi:10.1016/j.ajog.2024.02.289

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。