机器人子宫肌瘤剔除术模拟模型的验证
本研究前瞻性评估低成本机器人子宫肌瘤剔除术模拟模型的有效性。12名住院医师和4名专科医生完成模拟任务,专家完成时间更短、GEARS及改良GEARS评分更高、任务错误更少。多数参与者认为模型真实且有用。
要点
- 专家任务完成时间中位数9.7分钟,新手24.6分钟,差异有统计学意义(p=.001)。
- 专家GEARS评分中位数23分,新手12分;改良GEARS评分36分对20分(p=.004)。
- 改良GEARS评分≥28分且错误≤28个被设为模拟任务通过标准。
核心结论
- 研究提供了支持低成本机器人子宫肌瘤剔除术模型有效性的证据,该模型和评估工具可作为机器人子宫肌瘤剔除术培训的教育工具。
研究设计与样本
- 前瞻性队列模拟研究,在外科模拟实验室进行,纳入12名妇产科住院医师和4名完成专科培训的微创妇科医生,新手与专家比例为3:1。
主要发现
- 专家任务完成时间中位数9.7分钟,新手24.6分钟(p=.001)。
- 专家GEARS评分中位数23分,新手12分(p=.004);改良GEARS评分专家36分,新手20分(p=.004)。
- 专家任务错误中位数15.5个,新手37.5个(p=.034)。
- 评分者间信度组内相关系数:GEARS为0.91,改良GEARS为0.93,任务错误为0.60。
- 62.5%的参与者认为模型真实,93.8%认为对培训有用。
关键数值与推荐
- 采用对比分组法设定模拟任务通过标准为改良GEARS评分最低28分且错误最多28个。
临床怎么用
- 原文未据此给出临床推荐。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
STUDY OBJECTIVE: Several simulation models have been evaluated for gynecologic procedures such as hysterectomy, but there are limited published data for myomectomy. This study aimed to assess the validity of a low-cost robotic myomectomy model for surgical simulation training. DESIGN: Prospective cohort simulation study. SETTING: Surgical simulation laboratory. PARTICIPANTS: Twelve obstetrics and gynecology residents and 4 fellowship-trained minimally invasive gynecologic surgeons were recruited for a 3:1 novice-to-expert ratio. INTERVENTIONS: A robotic myomectomy simulation model was constructed using <$5 worth of materials: a foam cylinder, felt, a stress ball, bandage wrap, and multipurpose sealing wrap. Participants performed a simulation task involving 2 steps: fibroid enucleation and hysterotomy repair. Video-recorded performances were timed and scored by 2 blinded reviewers using the validated Global Evaluative Assessment of Robotic Skills (GEARS) scale (5-25 points) and a modified GEARS scale (5-40 points), which adds 3 novel domains specific to robotic myomectomy. Performance was also scored using predefined task errors. Participants completed a post-task questionnaire assessing the model's realism and utility. MEASUREMENTS AND MAIN RESULTS: Median task completion time was shorter for experts than novices (9.7 vs 24.6 min, p = .001). Experts scored higher than novices on both the GEARS scale (median 23 vs 12, p = .004) and modified GEARS scale (36 vs 20, p = .004). Experts made fewer task errors than novices (median 15.5 vs 37.5, p = .034). For interrater reliability of scoring, the intraclass correlation coefficient was calculated to be 0.91 for the GEARS assessment, 0.93 for the modified GEARS assessment, and 0.60 for task errors. Using the contrasting groups method, the passing mark for the simulation task was set to a minimum modified GEARS score of 28 and a maximum of 28 errors. Most participants agreed that the model was realistic (62.5%) and useful for training (93.8%). CONCLUSION: We have demonstrated evidence supporting the validity of a low-cost robotic myomectomy model. This simulation model and the performance assessments developed in this study provide further educational tools for robotic myomectomy training.
引用
- Schneyer RJ, Scheib SA, Green IC, et al. Validation of a Simulation Model for Robotic Myomectomy. J Minim Invasive Gynecol. 2024. PMID: 38307222. doi:10.1016/j.jmig.2024.01.011
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。