文献速递产科母胎医学

胎儿大小与生长:基于孕晚期估计胎儿体重三种生长速度模型识别死产风险的比较分析

Fetal size vs growth: comparative analysis of 3 models of growth velocity based on third trimester estimated fetal weights for identifying stillbirth risk.
PubMed 文献 · Am J Obstet Gynecol · 2023-12-25

在新西兰71,576例有至少两次孕晚期超声的妊娠中,回顾性分析三种生长速度模型识别死产风险的能力:50百分位下降、30百分位下降和低于预测最佳体重范围。两种百分位模型未能识别末次扫描非小于胎龄儿的额外高危病例,而预测体重范围法额外识别79%非小于胎龄儿的慢生长病例,其死产风险显著升高(相对风险2.0;95%CI 1.2-3.4)。

要点

  • 百分位下降模型未识别出末次扫描非小于胎龄儿的额外死产高危病例。
  • 预测体重范围法额外识别79%非小于胎龄儿慢生长病例,死产相对风险2.0(95%CI 1.2-3.4)。
  • 基于百分位的模型不能反映体重增长的充分性,尤其分布极端时。

核心结论

  • 基于百分位的方法不能反映胎儿体重增长在分布极端情况下的充分性。
  • 支持此类模型的指南可能妨碍产前评估胎儿生长速度的潜在益处。
  • 一种新的、按测量间隔制定的预期胎儿体重增长预测模型可识别非小于胎龄儿但因生长缓慢而有死产风险的胎儿。

研究设计与样本

  • 回顾性分析新西兰前瞻性记录的常规保健数据,纳入有2次或以上孕晚期扫描的妊娠,分析最后2次扫描结果。
  • 研究队列共71,576例妊娠,最后2次扫描平均在孕32+1周和35+6周进行。
  • 评估三种定义慢生长的模型:测量间50百分位下降、30百分位下降、估计胎儿体重低于基于预定扫描间隔特定切点的预测最佳体重范围。

主要发现

  • 三种模型定义慢生长的比例分别为:50百分位下降0.9%、30百分位下降5.1%、低于预测最佳体重范围10.8%。
  • 两种基于百分位的模型均未识别出末次扫描非小于胎龄儿的额外高危病例。
  • 预测体重范围法额外将79%的非小于胎龄儿病例识别为慢生长,这些病例死产风险显著升高(相对风险2.0;95%CI 1.2-3.4)。

局限性

  • 原文未报告局限性

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

BACKGROUND: Fetal growth velocity is being recognized as an important parameter by which to monitor fetal wellbeing, in addition to assessment of fetal size. However, there are different models and standards in use by which velocity is being assessed. OBJECTIVE: We wanted to investigate 3 clinically applied methods of assessing growth velocity and their ability to identify stillbirth risk, in addition to that associated with small for gestational age. STUDY DESIGN: Retrospective analysis of prospectively recorded routine-care data of pregnancies with 2 or more third trimester scans in New Zealand. Results of the last 2 scans were used for the analysis. The models investigated to define slow growth were (1) 50+ centile drop between measurements, (2) 30+ centile drop, and (3) estimated fetal weight below a projected optimal weight range, based on predefined, scan interval specific cut-offs to define normal growth. Each method's ability to identify stillbirth risk was assessed against that associated with small-for-gestational age at last scan. RESULTS: The study cohort consisted of 71,576 pregnancies. The last 2 scans in each pregnancy were performed at an average of 32+1 and 35+6 weeks of gestation. The 3 models defined "slow growth" at the following differing rates: (1) 50-centile drop 0.9%, (2) 30-centile drop 5.1%, and (3) below projected optimal weight range 10.8%. Neither of the centile-based models identified at-risk cases that were not also small for gestational age at last scan. The projected weight range method identified an additional 79% of non-small-for-gestational-age cases as slow growth, and these were associated with a significantly increased stillbirth risk (relative risk, 2.0; 95% CI, 1.2-3.4). CONCLUSION: Centile-based methods fail to reflect adequacy of fetal weight gain at the extremes of the distribution. Guidelines endorsing such models might hinder the potential benefits of antenatal assessment of fetal growth velocity. A new, measurement-interval-specific projection model of expected fetal weight gain can identify fetuses that are not small for gestational age, yet at risk of stillbirth because of slow growth. The velocity between scans can be calculated using a freely available growth rate calculator (www.perinatal.org.uk/growthrate).

来源:Am J Obstet Gynecol,查看原文。版权归原作者所有。