文献速递产科妇科

超声诊断妊娠物残留准确性的系统评价与Meta分析

The accuracy of ultrasound scan in diagnosing retained products of conception: a systematic review and meta-analysis.
PubMed 文献 · Am J Obstet Gynecol · 2023-11-25

本系统评价与Meta分析纳入11项前瞻性或回顾性横断面或队列研究、共1567例参与者,评估超声诊断妊娠物残留的准确性。结果显示,高回声团块的敏感度、特异度及诊断比值比最高,分别为0.915、0.843和57.787;子宫内膜厚度阈值设为10 mm时敏感度0.667、特异度0.866;彩色多普勒血流敏感度0.850、特异度0.406。作者结论为高回声团块是任何妊娠事件后妊娠物残留最敏感和特异的预测指标。

要点

  • 高回声团块预测妊娠物残留的敏感度0.915、特异度0.843、诊断比值比57.787。
  • 子宫内膜厚度阈值10 mm时敏感度0.667、特异度0.866、诊断比值比12.927。
  • 彩色多普勒血流敏感度0.850、特异度0.406、诊断比值比3.893。

核心结论

  • 高回声团块是任何妊娠事件后妊娠物残留最敏感和特异的预测指标。
  • 本综述最重要的局限性是纳入研究的设计导致显著的统计学异质性。

研究设计与样本

  • 系统评价与Meta分析,纳入前瞻性和回顾性横断面或队列研究。
  • 共纳入11项研究,参与者共1567例。
  • 检索来源包括Ovid SP、Cumulative Register to Nursing & Allied Health Literature、EBSCO、Core、Trip、Networked Digital Library of Theses and Dissertations Global ETD search、BMJ Best Practice、PubMed、GreyLit报告网站、Cochrane Central Register of Controlled Trials和Google scholar。
  • 纳入标准为评估妊娠物残留处理前超声表现与处理后组织病理学结果的研究,涵盖所有孕周。
  • 使用Covidence提取数据和质量评估,使用RevMan 5.4、MetaDTA 2.01和Meta-DiSc 2.0在线软件进行Meta分析。

主要发现

  • 9项研究分析高回声团块的准确性,其敏感度0.915(95%CI 0.844-0.955)、特异度0.843(95%CI 0.615-0.947)、诊断比值比57.787(95%CI 15.171-220.112)。
  • 4项研究分析子宫内膜厚度的准确性,诊断阈值设为10 mm,敏感度0.667(95%CI 0.072-0.981)、特异度0.866(95%CI 0.375-0.986)、诊断比值比12.927(95%CI 0.23-726.582)。
  • 5项研究分析彩色多普勒血流的准确性,敏感度0.850(95%CI 0.756-0.913)、特异度0.406(95%CI 0.198-0.655)、诊断比值比3.893(95%CI 1.005-15.081)。
  • 高回声团块的敏感度、特异度和诊断比值比在三种超声方法中最高。

关键数值与推荐

  • 高回声团块:敏感度0.915(95%CI 0.844-0.955)、特异度0.843(95%CI 0.615-0.947)、诊断比值比57.787(95%CI 15.171-220.112)。
  • 子宫内膜厚度阈值10 mm:敏感度0.667(95%CI 0.072-0.981)、特异度0.866(95%CI 0.375-0.986)、诊断比值比12.927(95%CI 0.23-726.582)。
  • 彩色多普勒血流:敏感度0.850(95%CI 0.756-0.913)、特异度0.406(95%CI 0.198-0.655)、诊断比值比3.893(95%CI 1.005-15.081)。

临床怎么用

  • 原文未据此给出推荐。

局限性

  • 本综述最重要的局限性是纳入研究的设计导致显著的统计学异质性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

OBJECTIVE: This study aimed to analyze and summarize the evidence on the accuracy of different ultrasound methods in the diagnosis of retained products of conception. DATA SOURCES: We searched Ovid SP, the Cumulative Register to Nursing & Allied Health Literature, EBSCO, and grey literature including Core, Trip, Networked Digital Library of Theses and Dissertations Global ETD search, BMJ Best Practice, PubMed, GreyLit report website (http://www.greylit.org/), Cochrane Central Register of Controlled Trials, and Google scholar (https://scholar.google.com/). STUDY ELIGIBILITY CRITERIA: We included prospective and retrospective cross-sectional or Cohort studies that evaluated both ultrasound findings (before management of retained products of conception) and histopathologic results of retained products of conception at all gestational ages. METHODS: We used Covidence for data extraction from the studies and quality assessment. The meta-analysis was performed using RevMan 5.4 (forest plot), MetaDTA version 2.01, and Meta-DiSc 2.0 online software. RESULTS: In total, 11 studies were eligible for data extraction and meta-analysis. The total number of study participants from these 11 studies were 1567. Of these, 9 studies were included to test the accuracy of an echogenic mass, 4 studies analyzed the accuracy of endometrial thickness, and 5 studies analyzed the accuracy of color Doppler flow to predict retained products of conception. We found that echogenic mass had the highest sensitivity, specificity, and diagnostic odds ratio for predicting retained products of conception. The sensitivity, specificity, and diagnostic odds ratio were 0.915 (95% confidence interval, 0.844-0.955), 0.843 (95% confidence interval, 0.615-0.947), and 57.787 (95% confidence interval, 15.171-220.112), respectively. The diagnostic threshold for endometrial thickness was set at 10 mm with a sensitivity, specificity, and diagnostic odds ratio of 0.667 (95% confidence interval, 0.072-0.981), 0.866 (95% confidence interval, 0.375-0.986), and 12.927 (95% confidence interval, 0.23-726.582). The sensitivity, specificity, and diagnostic odds ratio of color Doppler flow were 0.850 (95% confidence interval, 0.756-0.913), 0.406 (95% confidence interval, 0.198-0.655), and 3.893 (95% confidence interval, 1.005-15.081). CONCLUSION: Our review concluded that an echogenic mass is the most sensitive and specific predictor of retained products of conception after any pregnancy event. The most important limitation of our review is that the design of the studies included led to significant statistical heterogeneity.

来源:Am J Obstet Gynecol,查看原文。版权归原作者所有。

引用

  1. Sundararajan S, Roy S, Polanski LT, et al. The accuracy of ultrasound scan in diagnosing retained products of conception: a systematic review and meta-analysis. Am J Obstet Gynecol. 2023. PMID: 38008149. doi:10.1016/j.ajog.2023.11.1243

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。