超声诊断子宫平滑肌瘤与子宫肉瘤的诊断准确性
该系统综述检索5个电子数据库(MEDLINE、Web of Sciences、Google Scholar、Scopus及ClinicalTrial.gov)自建库至2023年6月,纳入报告术后组织学诊断且术前行超声评估的观察性或随机临床试验,共972例女性(694例子宫平滑肌瘤、278例子宫肉瘤)。超声汇总敏感度为0.76(95%CI 0.70-0.81),特异度为0.89(95%CI 0.87-0.92),阳性似然比6.65(95%CI 4.45-9.93),阴性似然比0.26(95%CI 0.07-1.0),诊断比值比23.06(95%CI 4.56-116.53),汇总受试者工作特征曲线下面积0.8925。作者认为超声在子宫平滑肌瘤与子宫肉瘤的鉴别诊断中似乎仅具有中等诊断准确性,敏感度低于特异度。
要点
- 超声鉴别子宫平滑肌瘤与肉瘤的汇总敏感度为0.76(95%CI 0.70-0.81)。
- 超声鉴别子宫平滑肌瘤与肉瘤的汇总特异度为0.89(95%CI 0.87-0.92)。
- 作者认为超声仅具有中等诊断准确性,敏感度低于特异度。
核心结论
- 作者认为超声在子宫平滑肌瘤与子宫肉瘤的鉴别诊断中似乎仅具有中等诊断准确性,敏感度低于特异度。
研究设计与样本
- 系统综述检索MEDLINE、Web of Sciences、Google Scholar、Scopus及ClinicalTrial.gov共5个电子数据库,检索时间自建库至2023年6月。
- 纳入报告术后无偏倚组织学诊断子宫平滑肌瘤或子宫肉瘤、且术前行子宫肿块超声评估的同行评议观察性或随机临床试验。
- 共纳入972例女性,其中694例子宫平滑肌瘤、278例子宫肉瘤。
主要发现
- 超声汇总敏感度为0.76(95%CI 0.70-0.81)。
- 超声汇总特异度为0.89(95%CI 0.87-0.92)。
- 超声汇总阳性似然比为6.65(95%CI 4.45-9.93),阴性似然比为0.26(95%CI 0.07-1.0)。
- 超声汇总诊断比值比为23.06(95%CI 4.56-116.53),汇总受试者工作特征曲线下面积为0.8925。
关键数值与推荐
- 超声汇总敏感度为0.76(95%CI 0.70-0.81)。
- 超声汇总特异度为0.89(95%CI 0.87-0.92)。
- 超声汇总阳性似然比为6.65(95%CI 4.45-9.93),阴性似然比为0.26(95%CI 0.07-1.0)。
- 超声汇总诊断比值比为23.06(95%CI 4.56-116.53),汇总受试者工作特征曲线下面积为0.8925。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
BACKGROUND: Differential diagnosis between uterine leiomyomas and sarcomas is challenging. Ultrasound shows an uncertain role in the clinical practice given that pooled estimates about its diagnostic accuracy are lacking. OBJECTIVES: To assess the accuracy of ultrasound in the differential diagnosis between uterine leiomyomas and sarcomas. DATA SOURCES: A systematic review was performed searching 5 electronic databases (MEDLINE, Web of Sciences, Google Scholar, Scopus, and ClinicalTrial.gov) from their inception to June 2023. METHODS OF STUDY SELECTION: All peer-reviewed observational or randomized clinical trials that reported an unbiased postoperative histologic diagnosis of uterine leiomyoma or uterine sarcoma that also comprised a preoperative ultrasonographic evaluation of the uterine mass. TABULATION, INTEGRATION, AND RESULTS: Sensitivity, specificity, positive and negative likelihood ratios, diagnostic odds ratio, and area under the curve on summary receiver operating characteristic were calculated for each included study and as pooled estimate, with 95% confidence interval (CI); 972 women (694 with uterine leiomyomas and 278 with uterine sarcomas) were included. Ultrasound showed pooled sensitivity of 0.76 (95% CI, 0.70-0.81), specificity of 0.89 (95% CI, 0.87-0.92), positive and negative likelihood ratios of 6.65 (95% CI, 4.45-9.93) and 0.26 (95% CI, 0.07-1.0) respectively, diagnostic odds ratio of 23.06 (95% CI, 4.56-116.53), and area under the curve of 0.8925. CONCLUSIONS: Ultrasound seems to have only a moderate diagnostic accuracy in the differential diagnosis between uterine leiomyomas and sarcomas, with a lower sensitivity than specificity.
引用
- Raffone A, Raimondo D, Neola D, et al. Diagnostic Accuracy of Ultrasound in the Diagnosis of Uterine Leiomyomas and Sarcomas. J Minim Invasive Gynecol. 2023. PMID: 37778636. doi:10.1016/j.jmig.2023.09.013
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。